Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Repeat Failures of Letdown Valves
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Repeat Failures of Letdown Valves

Repeat Failures of Letdown Valves

Instrumentation engineering root cause analysis (RCA) of letdown valves repeat failures in industrial plant.

Last updated: September 28, 2022 3:02 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
4 Min Read
SHARE

Instrumentation engineering root cause analysis (RCA) of letdown valves repeat failures in industrial plant.

Contents
Repeat Failures of Letdown ValvesFinal SolutionRCA solution Benefits
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Control Valves
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Repeat Failures of Letdown Valves

As foreseen, within a week failed PCV 205 S shut down the plant chaotically.

Crew bolted the as soon as possible (ASAP) readied and carbon-steel flanges screwed valve PCV 205 to the pipeline and production resumed in 6 hours. The wisely screwed-in CS flanges reduced the downtime by 2 hours. 

As before crew readied spare valve PCV 205S too ASAP and vigorously considered plug to stem strengthening.

Also Read: First Time Letdown Valve Problem

Final Solution

The SS 329 plug broke into two while welding to the stem. Hence, the author decided to use No Joint Inner Valve (NJIV) braving the below given two constraints and the valve maker not approving it.

  1. The manufacturer neither supplied the NJIV nor approved making it out of SS 329 citing reasons of standards permit only resilient SS 316 stem screwed to erosion resistant hard SS 329 plug and 329’s non-weldability.
  2. Still the author got SS NJIV turned overcoming the below given constraints:
  3. Suitable size SS 329 bar stock non-availability
  4. Excessive materials and efforts waste by turning the Max 40 mm dia NJIV out of the only 124 mm dia x 1.5 m long carbomate pump discarded plunger.
  5. He got a 800 mm long piece cut, tacked it vertically to a large plate. A crew of 2 working for two hours and another taking over hacksawed it into 4 quadrants in 12 hours. The shop turned out the two NJIVs one each for PCV 205 and PCV 205 S. They saved remaining two for other uses.
  6. Instrument crew readied PCV 205 with the NJIV. It went on the line at a soonest shutdown opportunity. It failed never! The author believes no joint and the generous fillet radius he provided where the dia reduces from 38 to 25.4 mm are the reasons for the IVs success. 

Crew readied PCV 205 S with NJIV. However, it has become a non-moving spare!

RCA solution Benefits

A lasting and least-cost solution for a DDUDP.

The valve PCV 205 inspected at 3‑years intervals is excellent.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Valve Positioners Failed
  • Errors and Faults in Siemens PLC
  • Electrical Engineering Problems
  • Pressure Taps Block Valves Leaks
  • Unstable & Drifting Values of Transmitter
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Urea Reactor Top Bolted Plug developed Leaks
Fired Boiler Induced Draft Fan (IDF) Failures Upset all Plants Operations
Erratic Radar Level Gauges Delays a Refinery Commissioning
Fan Motor Frequent Journal Bearing Failures Posed Plant Outages
Control Valve Passing Problem after Overhauling Job
Critical High KiloWatt Motor Winding Burnout Threats
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

How Kalrez O-rings Seal So effectively So Long?
8000 RPM 8000 kW Turbine Problem
High-pressure Service Level Transmitters Misunderstood Zero Drifts
Learnings from the BP Refinery Explosion at Texas City
HT motors Corrosion Problem
Flange Joint Errors shutdowns root cause analyzed and eliminated
Discharge Head 3‑monthly leaks of Steam Turbine Driven Centrifugal Compressors
Gas Cooler Re-tubing Done Successfully (Root Cause Analysis)

Keep Learning

Reformer Fan Bearing Change Times cut by 90%

Reformer Fan Bearing Change Times cut by 90%

Flanged Rotameter

Flanged Rotameter Caused Pipe Weld Cracks and Gives Wrong Readings

Control Valves Leak Tightness

Control Valves Leak Tightness Restoration Pose Difficulties

Recurring Short Circuit Flash Overs Safety Hazards

Recurring Short Circuit Flash Overs Safety Hazards & Damages

Malfunctioning Inlet Check Valves

Malfunctioning Inlet Check Valves caused chaos at Compressor stop/trip

Solenoid Valve Failure in Plant Start-Up

Solenoid Valve Failure in Plant Start-Up: Identifying the Root Cause

Sprocket Assembly and Bolting Segments

Bucket elevators Chain and teeth wear Problems

Industrial Light Fittings and Street Light Poles Corrosion Problems

Industrial Light Fittings and Street Light Poles Corrosion Problems

Learn More

PLC Compressor Control Ladder Logic

PLC Compressor Control Ladder Logic

Safety Questions and Answers

Safety Questions and Answers

Oil Burners

What are Oil Burners? Types, Advantages, Applications

Problem with Pirani Gauge

Problem with Pirani Gauge

Online PLC Ladder Logic

Mis-conceptions of PLC Ladder Logic

Advances in Control System

Fuzzy Logic Control

Contextual HMI

What is Contextual HMI? – HMI Screens on a Mobile or Tablet

Stilling well in liquid level measurement

Stilling Well in Interface Level Measurement System

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?