  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Erratic H2 Flow Rotameter
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Erratic H2 Flow Rotameter

Erratic H2 Flow Rotameter

Erratic H2 flow rotameter readings prevented newly charged catalyst reduction and delayed Reformed Gas Production.

Last updated: September 28, 2022 2:55 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
2 Min Read
SHARE

Instrumentation engineering root cause analysis of erratic reading of H2 flow rotameter.

Contents
Flow Rotameter ProblemInstrument Crew’s difficultiesPipe fitters’ woesAuthor Solution
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Sensors
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Flow Rotameter Problem

Erratic H2 flow rotameter readings prevented newly charged catalyst reduction and delayed Reformed Gas Production.

Instrument Crew’s difficulties

The instrument crew complained about the pipe fitter’s inability to make the ¾ pipe exactly vertical. Hence, stuck rotameter float and unreliable readings

Pipe fitters’ woes

They too expressed the near impossibility of the slender ¾” pipeline ‘rotameter plumb’. Even if they achieve it, it does not stay that way!

Author Solution

He told the Instrument crew to do the following:

Erratic H2 Flow Rotameter
  1. Workshop to make a 2” pipe stand to mount the rotameter using instrument engineer given sketch
  2. Miscellaneous contractor to grout it vertically to the cement floor under instrument engineer supervision
  3. Instrument crew to bolt the rotameter on the stand vertical and lock the fasteners with lock nuts
  4. Pipe fitters to connect the pipe flanges to the rotameter strain free i.e. just by hand position the pipes to match the rota meter flanges

Problems vanished and reformer started smoothly.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Level Transmitters Zero Drifts
  • Target Flow Transmitters Failed
  • Pitot-tube Replaced with Orifice
  • Mechanical Temperature Indicator
  • Seal Pressure Instruments Problems
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Too Low-Temperature Readings after a Failed Thermocouple Change
Leaky Boiler Drum Level Switch Stops NH3 Plant Commissioning
Hunting of Control Valves
Condensate Pump Frequent Wrecks Threatens Long Plant Outages
HT Motor Direction of Rotation (DOR) Changed
Stuck Segment Orifice Dimensions Calculations
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

[RCA] Pump Low throughput Eliminated
Pressure Correction Pneumatic Instrumentation
Problems with Demister Pads – Root Cause Analysis (RCA)
Root Cause Analysis of Differential Pressure Level Transmitter
Compressor IP Case Discharge Temperature Gradually Increases
Control Valves – Repeat Actuator Diaphragm Bursts
Frequent Feeder-A Lightning Arrester (LA) Bursts – Root Cause Analysis
Thermowell Shank to Flange Repeat Weld Leaks

Keep Learning

On Off Valve Root Cause Analysis

Root Cause Analysis for FRP Line Damaged due to On-Off Valve

Jacket Added Seawater Pipe Spool

Seawater Pipeline Spools from day-1 leaks threaten Plant Shutdown

Innovative Segment Orifice

Pitot-tube Replaced with Innovative Segment Orifice Plate

Packing Compressing Die Set

Carbamate Plunger Pump Packing Problems Eliminated

Rotary Granulator Drive

Rotary Granulator Drive Root Cause Analysis (RCA)

Questions and Answers on Motors and Generators

HT Motor Problem appears after Disassembly and Reassembly

RF and RTJ Flange Installed Gasket

Flange Joint Errors shutdowns root cause analyzed and eliminated

Centrifugal Compressor outage reduced

Centrifugal Compressor Outage Reduced – Root Cause Analysis

Learn More

Forward reverse motor control diagram with timer

Timer during Motor Direction Change PLC Program

steadily pour a liquid into vertical tube

Vertical Tube Liquid Level Equilibrium

Magnetic Float Level Sensor Principle

Magnetic Float Level Transmitter Working Principle

Power Electronics Objective Questions

Power Electronics Diode Circuits Quiz

Ethernet IP Commissioning Tool software

How to Configure IP Address in Rockwell PLC?

Magnetic Tape Recorder Principle

What is Magnetic Tape Recorder ?

PLC Logic to identify empty bottles in Packing

Automatic Empty Bottle detection using PLC Logic

PLC Valve Control Example

Create a Function (FC) for a Valve Logic in Siemens PLC

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?