Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Primary Reformer RFG main Hot Spots threaten Indefinite Outage
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Primary Reformer RFG main Hot Spots threaten Indefinite Outage

Primary Reformer RFG main Hot Spots threaten Indefinite Outage

Root Cause Analysis (RCA) related to primary reformer RFG main hot spots threaten indefinite outage eliminated.

Last updated: September 28, 2022 3:15 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
5 Min Read
SHARE

Root Cause Analysis (RCA) related to primary reformer RFG main hot spots threaten indefinite outage eliminated.

Contents
ProblemPrimary Reformer RFG main Hot Spots ProblemRoot Cause AnalysisRepair OptionsFinal SolutionSuccess
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Pipelines and Miscellaneous Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Problem

Reformed Gas (RFG) collecting main hot spots: gas collecting main conveying the reformer produced 800o C and 35 bars pressure RFG to the secondary reformer developed hot spots threatening the indefinite shutdown.

Primary Reformer RFG main Hot Spots Problem

The below figure shows the gas collecting main details. RFG passes through loose couplers joined 6 m long x 150 mm dia x 3 mm wall thickness (WT) Incoloy pipes concentric to 300 mm dia x 25 mm WT welded all over CS pipes. Cast refractory fills the annular space.

repairs of welding cast refractory lined box over the hot spots

The hot gases’ small leaks percolating into the refractory eventually cool down as continuous large quantities of gas flow paths are absent. Thus, 800 deg C and H2 rich RFG wets the expensive suitable Incoloy and not the CS jacket, incompatible to the hot RFG.

In addition, the gas leaking out of the coupler joints pressures the annulus to near 35-bars; hence, the incolloy pipes handle zero differential pressure only.

Hence, the very small 3 mm thickness suffices. Such a design minimizes expensive incolloy use and reduces the system costs by 60 to 70%.

To summarize, inexpensive thick walled CS pipes handle the pressure at low temperatures, and expensive thin walled incolloy pipes the high temp and H2 attack; CS is incompatible to both.  

Root Cause Analysis

Why hot spots? Probably excessive refractory cracks at different locations allow unacceptable quantities of 800o C RFG to circulate around.

Repair Options

The first suggested option was:

  1. Shut down the reformer and cool it down –– several days of dreaded task
  2. Flame cut the 30o hot spot CS pipe segment sufficient length.
  3. Steam pressure the reformer tubes to 1 bar
  4. Identify refractory leaks and repair The author thanked the proposer and invited all to come out with easier, safer, shorter SD and surer solution as soon as possible as living with the hot spots is unsafe. 

Final Solution

After 3-thinking days, the author implemented below described steps to solve the problem:

  1. Crew welded 20 Nos. ¾” 6000 PSI sockets with welded gate valves distributed around the hot spot area
  2. During a 1 shift shut down, under 1-bar steam pressure, a crew at one end and another at the other end drilled 10 mm dia holes on the pipe. A stopper prevented drilling deep into the refractory
  3. injected a specialist company provided  refractory slurry for 5 minutes, at each of the taps (fig 42), stopped and closed the valve
  4. After injection at all the taps they waited for 10 minutes and repeated the injection and hoped for the best
  5. The crew plugged all closed valves outlets.

Success

Operators started the reformer feeds and firing. No leaks at plugged valve ends and no hot spot delighted everyone.

Crew seal welded the plugs 4-hours later for extra caution against leaks. The great success attempt averted threatened indefinite total plant shutdown.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Plug Valves Leaks
  • Rupture Discs bursts
  • Trip Throttle Valve RCA
  • Repeat Safety Valve Popping
  • Steam Letdown Station Problems


.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Burst Transformer – Electrical Problem Solved
Compressor Cracked Shaft Spacers
Root Cause Analysis – Burst Transformers and 11 kV Input Breakers
Target Flow Transmitters Failed the Very Midnight
Pitot-tube Replaced with Innovative Segment Orifice Plate
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Rupture Disc

Rupture Discs bursts caused too many Urea Plant Shutdowns

Control Valves Leak Tightness

Control Valves Leak Tightness Restoration Pose Difficulties

Root Cause Analysis on Hunting of Control Valves

Hunting of Control Valves

repairs of welding cast refractory lined box over the hot spots

Too often done riskily repaired Roof Hot Spots eliminated forever

Reformer Fan Bearing Change Times cut by 90%

Reformer Fan Bearing Change Times cut by 90%

Steam Letdown Station Problems

Steam Letdown Station Problems and their Solutions

Control Valve Plug Stem and Gland Leaks

Repeat Control Valve Plug Stem and Gland Leaks

Arc Fault Breaker (AFB) Electrical Problem Solved

Arc Fault Breaker (AFB) Electrical Problem Solved

More Articles

Difference Between AIS and GIS Panels

Difference Between AIS and GIS Panels

light-emitting-diode-theory

Light Emitting Diode Operation

PLC program Permissive Circuit

PLC Electric Motor Interlocks

pilot-operated pressure relief valve

Pilot-operated Safety and Relief Valves

Control Systems Questions & Answers

Control Systems Objective Questions & Answers – Set 2

Clamp Meter

What is a Clamp Meter?

Area Velocity Flow Meter Principle

Area Velocity Flow Meter Principle

WHILE DO Statement in SCL Language

WHILE DO Statement in SCL Language

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?