Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: HT Motor Problem appears after Disassembly and Reassembly
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > HT Motor Problem appears after Disassembly and Reassembly

HT Motor Problem appears after Disassembly and Reassembly

Electrical engineering root cause analysis (RCA) related to HT motor problem appears after disassembly and reassembly.

Last updated: September 28, 2022 3:02 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
2 Min Read
SHARE

Electrical engineering root cause analysis (RCA) related to HT motor problem appears after disassembly and reassembly.

Contents
HT Motor ProblemAuthor Root Cause AnalysisMotor disciplined!
Article Type:Root Cause Analysis (RCA)
Category:Electrical
Equipment Type:Miscellaneous
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

HT Motor Problem

The crew disassembled a 3.3.KV 400 KW 3000 RPM Journal Bearing Motor, completed DOR change tasks and assembled it back.

On energizing with workshop test 400 V supply, the rotor instead of running at the magnetic center after few seconds of axial wandering moved axially to the extreme.

The shaft collar hitting the bearing end stopped further shaft axial movement – misbehavior indeed!

Misbehaving HT Motor disciplined
Example Image

Author Root Cause Analysis

Since the problem appears after disassembly, obviously reassembly errors are most likely.

Close motor inspection showed no match marks on the end shields!

Possibly, the left end shield has gone to the right and vice versa.

Motor disciplined!

Motor disassembly after careful match marking and assembling back solved the problem.

The sheepishly grinning electrical crew leader said, “Sir, I assumed the end-shields are interchangeable; hence, I disassembled the motor without match marks.”

The author explained, “Never assume; always be sure. Assume really splits as “ASS-U-Me”; i.e. it makes an ass of you and me, as it did this time!”

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Welding Machine Problems
  • Miscellaneous Electrical Tasks
  • 11 KV Bus A to Bus B Phase Check
  • Inability to Test Repaired HT Motors
  • Street Light Poles Corrosion Problems
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Root Cause Analysis – Burst Transformers and 11 kV Input Breakers
Fasteners and General Corrosion of Electrical Motors
None Could Repair Slightly Damaged Magnetic Flow Meter Flow Tube
Repeat Safety Valve Popping caused Urea Plant Shutdown
Pump 3-monthly Seal Leaks threaten entire Plant Shut down Indefinitely
Arc Fault Breaker (AFB) Electrical Problem Solved
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Hunting of Control Valves
Readers Questions on Flow Transmitter
Repeat Failures of Letdown Valves
Instrumentation Engineering Problems Solved – Root Cause Analysis
Burst Transformer – Electrical Problem Solved
Learnings from the BP Refinery Explosion at Texas City
Poor Power Factor Boosted – Industrial Electrical Problems
Pulverizer Electrical Problem Solved
Primary Reformer RFG main Hot Spots threaten Indefinite Outage
Gearbox within week Failing Journal Bearing upset Plant Operations

Keep Learning

Steam Turbine Driven Centrifugal Compressors Leak due to Broken Instrument

Steam Turbine Driven Centrifugal Compressors Leak due to Broken Instrument

NH3 Storage Tanks Ammonia Gas

NH3 Storage Tanks Ammonia Gas Venting Issue – Root Cause Analysis

Plant Shutdown Analysis: Valve Closed and SOV Coil Failure

Plant Shutdown Analysis: Valve Closed and SOV Coil Failure

Control Valve Passing Problem after Overhauling Job

Control Valve Passing Problem after Overhauling Job

On Off Valve Root Cause Analysis

Root Cause Analysis for FRP Line Damaged due to On-Off Valve

Temperature Sensors Fault

18 Temperature Sensors Fault Leads to Plant Shutdown

Pump Low throughput

[RCA] Pump Low throughput Eliminated

old Pressure Switches

Pressure Switch Frozen Screwed Cover Extends the Plant Shutdown

Discover More

Galileo thermometer Principle

Galileo Thermometer

30% Feed Control Valve

Purpose of 100% and 30% Feed Control Valves in a Power Plant

Reflex Level Gauge Parts

What is Reflex Level Gauge?

Solenoid Valve Terminology

How a Solenoid valve works

Instrumentation Bulk Material

Instrumentation Bulk Material Requirements in Oxygen Service

Anti Surge Controller Theory

Anti Surge Controller Working Principle

Voting Logic in Safety Instrumented System (SIS)

Voting Logic in Safety Instrumented System (SIS)

Process Control Instrumentation Terms Glossary

Process Control Instrumentation Glossary

Follow US