Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Welding Machine Fail in Dusty and Corrosive Areas
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Welding Machine Fail in Dusty and Corrosive Areas

Welding Machine Fail in Dusty and Corrosive Areas

Electrical engineering root cause analysis (RCA) related to welding machines and their poor availabilities and often fail.

Last updated: September 28, 2022 3:02 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
2 Min Read
SHARE

Electrical engineering root cause analysis (RCA) related to welding machines and their poor availabilities and often fail.

Contents
Welding Machine FailAuthor Solution
Article Type:Root Cause Analysis (RCA)
Category:Electrical
Equipment Type:Welding Machines
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Welding Machine Fail

Motor Generator Welding Sets, (MGWS) and even Rectifier Welding Sets (RWS) of no moving parts fail often in dusty and corrosive areas.

Author Solution

The author got the RWS internals housed in a shop-made below given features tank:

  1. Radiators akin to transformers fitted oil circulating and heat radiating tubes
  2. Inside and outside epoxy painted
  3. Silica gel breather mounted and transformer oil filled

In addition, he ensured well-crimped tinned ‘hole drilled to suit terminal’ copper lugs to the Al welding cables, and well-tightened cable lugs by strict supervision to form a habit.

Gone are terminal burns, charred cable insulation, etc. Consequently, all welding machines were trouble-free forever. 

Added ‘snail conveyor belt covers’ as in TEFC motors to MGWS, and strictly ensured their cleaning and return to the workshop immediately after corrosive areas job completions. MGWSs too serve trouble-free forever.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Poor Power Factor Problem
  • HT Motor Direction of Rotation
  • Inability to Test Repaired HT Motors
  • General Corrosion of Electrical Motors
  • Light Fittings Corrosion Problems
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

HT motors Corrosion Problem
Root Cause Analysis – Burst Transformers and 11 kV Input Breakers
Centrifugal Compressor near ½-RPM Frequency High Magnitude Shaft Vibrations
Supplied Screen Vibrators Perennial Problems
Turbine Flow Meter (TFM) Field Calibration Uncommon Request
Transformers Coolers Weld Joints Oil Oozes Were Eye Sores
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Passing Control Valves Cause Yearly Losses in Production Plant
Captive Power Plant Trip Root Cause Analysis
Too often done riskily repaired Roof Hot Spots eliminated forever
Compressor Cracked Shaft Spacers
Rotary Granulator Drive Root Cause Analysis (RCA)
Arc Fault Breaker (AFB) Electrical Problem Solved
Erratic Stroking Control Valves Delaying the Shutdown Plant Restart
Refrigeration Compressor Turbine Not-tripping when needed Trip
Seawater Pipeline Spools from day-1 leaks threaten Plant Shutdown
Too Low-Temperature Readings after a Failed Thermocouple Change

Keep Learning

High-pressure Service Level Transmitters Misunderstood Zero Drifts

High-pressure Service Level Transmitters Misunderstood Zero Drifts

Instrumentation Engineering Root Cause Analysis

Instrumentation Engineering Problems Solved – Root Cause Analysis

Improved Sprocket Segment Bolting to body

A Plant Bucket Elevators chains too short chain lives problem eliminated

Innovative Segment Orifice

Pitot-tube Replaced with Innovative Segment Orifice Plate

Poorly Built Switchgears

Poorly Built Switchgears – Why Breaker Parts Tear apart or don’t work?

Reformer Tube Stress Relief Reusable Furnace

Miscellaneous Electrical Tasks – Repaired Reformer Tubes Weld Stress Relief

Bently Nevada Proximity Probe

Root Cause Analysis for Vibration Probe Not Responding

An Indian Plants all turbines’ low Vacuum

An Indian Plants all turbines’ low Vacuum & Saudi Plant turbo-compressor only

Discover More

simple latching motor control circuit

Motor Control Circuit Wiring

Things to Take Care of When Designing SCADA System

Things to Take Care of When Designing SCADA System

Tunnel Diode

Tunnel Diode Working Principle

Routine Tests of Transformers

Transformer Testing – Routine Tests of Transformers

Impulse Tubing Leak Test Checks

Impulse Tubing Leak Test Checks

PLC control 4 machines with 1 button

CX-Programmer Tutorial: 1 Button To Activate 4 Different Machines

Oscillating Piston Flow Meters Principle Animation

Nutating Disc Flow Meters Working Principle

Preventive Maintenance of Variable Frequency Drive

Preventive Maintenance of Variable Frequency Drive (VFD)

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?