Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Pulverizer Electrical Problem Solved
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Pulverizer Electrical Problem Solved

Pulverizer Electrical Problem Solved

Electrical engineering root cause analysis (RCA) related to pulverizer poor availabilities and the problem solved.

Last updated: September 28, 2022 3:08 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Electrical engineering root cause analysis (RCA) related to pulverizer poor availabilities and the problem solved.

Contents
Pulverizer ProblemAuthors SolutionBenefits of the RCA Solution
Article Type:Root Cause Analysis (RCA)
Category:Electrical
Equipment Type:Bus ducts, Switchgear, Transformers,
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Pulverizer Problem

Why low on stream hrs? Because of the V-belts coupling the 1500 RPM motor and 750 RPM pulverizer last max a month!

Why? The reasons are: 

  1. Because of corrosion and dust frozen Inoperable belt tensioners, the crew crow bar the first belt into first drive and driven pulleys’ grooves and crow bar it to the last grooves, groove by groove. All belts go this way. Thus they are ½ dead right at installation
  2. Belts running in the hygroscopic dust deposited pulley grooves slip, squeal to the high heavens and die within a month or often sooner
  3. Consequent 750 sets of V-belts and 24 pulleys sets changes reduce pulverizer availabilities to 50%, require frequent pulverizers changeovers etc. and tire the operation and maintenance crew unbearably and reduced production by 10 to 15%

Authors Solution

A few days ponder showed a way out:  the author recalled his college day pole changing motor topic; though he did not understand Motors application Handbook” given winding change details, and electrical engineers were diffident, a smart re-winder rewound a test motor for 750 RKM.

Its tire coupling coupled to a pulverizer did so well that all enthusiastically modified all the pulverizers’ drives within a month.

Benefits of the RCA Solution

The below are the mentioned benefits of the author’s solution.

  1. Rs 5, 00, 000 yearly savings from no pulleys and no belt changes
  2. No Crew overtime payments 
  3. 5% less power consumption i.e. yearly recurring Rs 5, 62, 000 – 1980 costs –  savings 
  4. Far higher pulverizers and motors bearing lives
  5. Pulverizers and hence plant availability shot by 10%
  6. Freedom from boring, repetitive and low-tech tasks boosted technicians and operators morale
  7. The operation and maintenance crew freed of dull low tech repeat chores thanked the author and spent the saved time for knowledge improvement
  8. Thanks to items 1-5, the modification pays for itself in a day

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Poorly Built Switchgears
  • Lightning Arrester Burst
  • 110 KV Connection to Feeder
  • Transformer Problem Solved
  • Replace Failed Motors Quickly
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

Instrumentation Engineering Problems Solved – Root Cause Analysis
Critical High KiloWatt Motor Winding Burnout Threats
Reformer Fan Bearing Change Times cut by 90%
Miscellaneous Electrical Tasks – Repaired Reformer Tubes Weld Stress Relief
Pressure Correction Pneumatic Instrumentation
Plant Shutdown Analysis: Valve Closed and SOV Coil Failure
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Centrifugal Compressor outage reduced

Centrifugal Compressor Outage Reduced – Root Cause Analysis

Minimum Oil Circuit Breaker (MOCB) Spares & Service

Minimum Oil Circuit Breaker (MOCB) No Vendor Spares & Service

Temperature Sensors Fault

18 Temperature Sensors Fault Leads to Plant Shutdown

Boiler Feed Water Heater Shell Flange Leaks

Boiler Feed Water Heater Shell Flange Leaks

Plunger Pump

Within Few Weeks Failing Acid Dozing Pumps

Alternate 110 KV Connection to Feeder A

Alternate 110 KV Connection to Feeder A

Refrigeration Compressor Turbine Not-tripping when needed Trip

Refrigeration Compressor Turbine Not-tripping when needed Trip

Phosphate Dozing System

Phosphate Dozing System Problems

More Articles

Orifice Plate Flow Requirements

What are the Orifice Plate Flow Requirements?

Instrumentation and Control Engineer Subject

Competency Factors of Instrument & Control Engineer (Design Engineering)

LRV and URV of PT for Extreme Limits of Empty and Full

LRV and URV of PT for Extreme Limits of Empty and Full

PLC Structured Text Program for Output Generation via Equations

PLC Structured Text Program for Output Generation via Equations

Charging Currents in Transmission Lines

Charging Currents in Transmission Lines

What is Instrumentation and Control

What is Instrumentation and Control ?

What is a Magnetic Field

Difference Between Electric Field and Magnetic Field

Purpose of End of Line (EOL) Resistor in Fire & Gas System ?

Why we use End of Line (EOL) Resistor in Fire and Gas System ?

Follow US