Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Within Few Weeks Failing Acid Dozing Pumps
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Within Few Weeks Failing Acid Dozing Pumps

Within Few Weeks Failing Acid Dozing Pumps

A plunger pump dozing sulfuric acid to a urea plant’s water treatment ion-exchange vessel stopped pumping after first week end.

Last updated: September 28, 2022 3:19 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Root Cause Analysis (RCA) related to the newly installed acid dozing pumps in a urea plant.

Contents
Acid Dozing PumpsAuthor SolutionProblem Identified and solution foundPump rush restoration Benefits
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Miscellaneous Rotating Machine Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Acid Dozing Pumps

A 15 KW plunger pump dozing sulfuric acid to a Saudi Arabian urea plant’s water treatment ion-exchange vessel stopped pumping after first week end.

The exasperated and desperate field crew left with no spare parts sought Author SOS assistance.

Author Solution

The author unfamiliar with the pump studied the instruction manual and sketched shown in below figure to show essentials.

Plunger Pump

The basics are

A motor driving a crank mechanism reciprocates the oil plunger pump (OPP), creates negative oil pressure in the forward stroke, the rubber diaphragm convex left, draw the acid in the pump chamber.

Plunger return stroke pressures the oil and the acid flows to the process opening the discharge valve. The suction valve closes and prevent acid flow back to the storage tank.

Problem Identified and solution found

brittle, hard, inflexible and cracked diaphragm showed its incompatibility to either sulfuric acid and or oil.

As no spare diaphragm was available, the author got the pump assembled back substituting between two 1.5 mm thick Teflon sheet discs rubber diaphragm cut from 4.5 mm thick conveyor belt – the thinnest available.

Pump rush restoration Benefits

Below given are the benefits of the rush innovative pump restoration:

  1. The assembled pump never failed and averted total ammonia and urea plant shut down
  2. On the vendor provided flimsy diaphragm lost a week only
  3. Both side Teflon sheet protected much stronger conveyor belt cut diaphragm is probably the reason

The acid delivery plunger pump became ‘fit & forget’.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Turbo-Compressor Problem
  • Compressor Anti-Surge Control
  • Plant Air Compressors Problems
  • Plant Turbo-compressor Problem
  • Failing Plant Air Compressor Drives
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Amine Pump Trip – Root Cause Analysis
Antifriction bearings (AFB) Problems and Delays Plant Restarts
Welding Machine Fail in Dusty and Corrosive Areas
Lessons Learned from Actuator Passing Incidents
Minimum Oil Circuit Breaker (MOCB) No Vendor Spares & Service
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Flanged Rotameter

Flanged Rotameter Caused Pipe Weld Cracks and Gives Wrong Readings

Steam Letdown Station Problems

Steam Letdown Station Problems and their Solutions

ISO 5167 Orifice Plate Types

Readers Questions on Flow Transmitter

Demister Pads Problem

Problems with Demister Pads – Root Cause Analysis (RCA)

Phosphate Dozing System

Phosphate Dozing System Problems

Card Failures in Automation Panels

Automation Panel Electronic Cards Failure investigation

Replace Failed Motors Quickly and Easily

Replace Failed Motors Quickly and Easily

Purpose of Isolation valve

Repeat Failures of Letdown Valves

More Articles

Electrical Machines Questions and Answers

Double Excited Magnetic System Quiz

HART-IP Principle

What is HART- IP ?

Gas-chromatograph-Working-Principle

Gas chromatograph Working Animation

Safety Instrumented System Engineer Interview Questions

Safety Instrumented Systems Online Exam

power-electronics-interview-questions

Power Electronics Interview Questions Part-1

Digital Electronics MCQ

Arithmetic Operation Objective Questions

Top Embedded Systems Projects for Engineers and Students

200 Top Embedded Systems Projects for Engineers and Students

Electronic Devices & Circuits Objective Questions

Electronic Devices & Circuits Quiz – Set 13

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?