Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Various Causes for PLC Going in Stop Mode
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > Various Causes for PLC Going in Stop Mode

Various Causes for PLC Going in Stop Mode

In this post, we will see the various causes which change the PLC operation to stop mode and its common reasons.

Last updated: October 17, 2023 3:42 pm
Viral Nagda
PLC Tutorials
No Comments
Share
5 Min Read
SHARE

In this post, we will see the various causes which change the PLC operation to stop mode.

Contents
Causes of PLC Stop ModeHardware ErrorSoftware ErrorRun/Stop Hardware Switch Run/Stop Digital InputMemory MismatchFull Downloading ProgramExternal Command from NetworkConclusion

A PLC basically has four modes of operation

  1. Run,
  2. Stop,
  3. Start-Up, and
  4. Hold.

The system on power-up starts by PLC going in stop mode. Immediately, it changes to start-up mode.

Causes of PLC Stop Mode

Various Causes for PLC Going in Stop Mode

This mode can be said as a way for three paths.

In the first path, the PLC again goes to stop mode if an error is detected.

In the second path, it goes to hold or halt mode if any breakpoint in the program is reached.

In the third possibility, if everything is fine, then the PLC goes to run mode.

Basically, here we will see some common reasons on why the PLC will go into stop mode:

Hardware Error

If any hardware error is detected in the PLC configuration, then the PLC mostly throws an error indication.

But, if the fault is such that it can damage the PLC system, then it will go into stop mode. It varies from PLC to PLC.

Generally, any critical fault; like internal wiring short circuit or power interruptions in the  PLC modules forces it to go to stop mode.

But, if there is a case where the module is not connected in the configured program of PLC; then too the PLC will remain in run mode.

Only an error will be thrown. So, as long as there is no major hardware fault, the PLC will remain in run mode.

Software Error

If there are some software bugs in program; like unhandled exception, watchdog error, overflow error, underflow error, infinite calculations etc. then the PLC will go in stop mode.

A simple example is, if you divide anything by zero in the PLC program, then the PLC will not be able to execute the logic and it will go in stop mode.

Thus, any wrongly written logic, which doesn’t have any solution or end; causes the PLC to go in stop mode.

Run/Stop Hardware Switch

Some PLC’s have a hardware switch on it; which is a selection of run or stop.

It is a safety measure provided in case of an emergency. If this switch is in stop mode, then the PLC won’t go into run mode.

 Run/Stop Digital Input

There are PLCs where you can assign a digital input to function as a run-stop switch.

That means, if this input is high, then only the PLC will function in run mode.

Memory Mismatch

In some PLC’s, there is a step to manually function a task to save the last done programming changes in the PLC memory.

If you do not do this task, and when you power reboots the PLC, then the PLC will go into stop mode.

Full Downloading Program

In any PLC, full downloading a program causes the PLC to go into stop mode.

External Command from Network

Nowadays, most of the PLC’s have the function of a web server embedded in it.

That means a programmer can access all the functions and configurations of the PLC by just entering the IP address of that PLC in the internet browser.

So, if that user has commanded stop logic from there, then the PLC will go into stop mode.

Conclusion

These are just the common examples. You need to always refer the diagnostic screen or variables of the PLC whenever you face such situations. It will be helpful in finding the exact cause of stop mode.

Author: Viral Nagda

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Learn PLC in Hindi
  • PID Simulator Download
  • High-Speed Inputs in PLC
  • Pause the Timer Ladder Logic
  • Basics of Industrial Control Systems
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
What is PCS 7?
Open Loop and Closed Loop System Questions Answers
PLC Program for Entry and Exit Control of Car Parking
Write a PLC Program for Selector Machine using Structured Text
PLC Programming to Control Lights in a Sequence
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Ladder Logic Counters Instruction

Up Counter PLC Program

How to Design a Motor Faceplate in Graphics - SCADA Tutorials

How to Design a Motor Faceplate in Graphics? – SCADA Tutorials

PLC Compressor Control Ladder Logic

PLC Compressor Control Ladder Logic

Communication between Intouch Scada and Allen Bradley PLC

Communication between InTouch Scada and Allen Bradley PLC

PLC Questions & Answers

Programmable Logic Controller Questions and Answers

Free Mitsubishi PLC Online Training Courses

Free Mitsubishi PLC Online Training Course and Tutorials

PLC Program Paint Spraying

PLC Program for Paint Spraying

Case Statement in SCL Language

Case Statement in SCL Language

More Articles

toroidal conductivity probe principle

Conductivity Analyzer Common Problems and Troubleshooting Tips

Temperature Switch Calibration

How to Calibrate Temperature Switch? – Instrument Basics

Patch Panel

What is a Patch Panel? Types and Uses in Networking

Transformers Questions and Answers

Latest Transformers Questions and Answers

Dew Point Method Humidity Measurement

Humidity Measurement Principle

Solenoid-controlled Valve Problem

Solenoid-controlled Valve Problem

Underground Cable Fault Identification Methods

Do’s and Don'ts in PLC

Do’s and Don’ts in PLC

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?