Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Thermowell Shank to Flange Repeat Weld Leaks
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Thermowell Shank to Flange Repeat Weld Leaks

Thermowell Shank to Flange Repeat Weld Leaks

Problems and Solutions: One or more failed flanged thermowell (TW) weld leaks are needed during plant shutdown repairs.

Last updated: September 28, 2022 2:51 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
4 Min Read
SHARE

Instrumentation engineering root cause analysis of thermowell weld leaks.

Contents
Thermowell Weld LeaksAuthor Root Cause AnalysisThermowell Leaks Vanished Eventually
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Instruments
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Thermowell Weld Leaks

One or more weld leaky thermowells (TW) are needed during opportune shutdown repairs. The repaired thermowells and few more welds leaked. Thus, the perennial TW weld leaks were a crying need.

Thermowell Immersion (IL) Length mm
Table: Thermowell Materials

Author Root Cause Analysis

The Root Cause Analyzing author found that many other more critical jobs loaded workshop let a less skilled welder and fitter team rush repair the leaky thermowells’ welds; hence, the perpetual leaky TWs!

The author figured replacing leaky thermowells (TWs) with spare high-quality welded TWs and competent crew repairing the removed leaky TWs would end the perennial TW repairs.

The table above lists the flange rating, material, and IL of the TWs in use. The many varieties discouraged holding spares. Fortunately, an idea flashed: the author: SS-316 serves in place of SS-304 but not vice versa;

In addition, the raised face dia of both 1½ 300# and 150 # flanges are equal 73 mm.  2 each IL 270 and 400 mm shank welded to  10 mm thick disc one side and even CS socket the other – the author named these disc thermowells (DTW) – are adequate spares.

Thus, holding just 4 Nos. of DTWs is adequate. Highly competent shop welder-mechanic team made these confirming to good engineering practice and standards shutdown pressures free.

Thermowell Leaks Vanished Eventually

The instrument crew put a suitable length DTW in place of a failed flanged thermowell (TW) and bolted to the process flange with a top placed CS flange as the process does not wet the CS flange during a plant shutdown (SD).

The shop repaired the removed Flanged TW after the SD according to good engineering practices and standards taking the required time SD pressures free.

In addition, the author got velocity collars welded to long shanks (below figure) to minimize shank vibrations amplitude to prevent weld cracks.

Thermowell Shank to Flange Repeat Weld Leaks

Velocity collars are 50 mm long SS 316 bushes of OD = Nozzle Bore dia – 1 mm) and ID = (shank dia +1mm). These minimize the process stream caused shank flutter amplitudes and thus the weld cracks risks.

Thanks to rotable spare DTWs enabled sound repairs and velocity collars where required, gone are the poor-quality shutdown rush TW repairs. Eventually, all leaky TWs ended well-repaired and never leaking.

Thus; leaky TW problems vanished forever economically and easily. So did the associated housekeeping efforts, environmental pollution problems, and expenses.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Target Flow Transmitters Failed
  • Multistage Flash Drums Readings
  • Rotameter Caused Pipe Weld Cracks
  • Level Instruments Stopped Working
  • Differential Pressure Transmitter Problem
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

NH3 Plant Turbo-compressor Sudden Rise in Temperature
Thermocouple Extension Lead Problem
Repeat Control Valve Plug Stem and Gland Leaks
Poorly Built Switchgears – Why Breaker Parts Tear apart or don’t work?
Ammonia Flash Vessel All Level Instruments Stopped Working
Ammonia Feed Ball Valve to Ship Tank Closed
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Gearbox within week Failing Journal Bearing upset Plant Operations
Leaky Boiler Drum Level Switch Stops NH3 Plant Commissioning
Turbine to Gearbox Alignment Drifts Caused Pump Transfers Problems
Learnings from the BP Refinery Explosion at Texas City
Miscellaneous Electrical Tasks – Repaired Reformer Tubes Weld Stress Relief
Plant Shutdown Analysis: Valve Closed and SOV Coil Failure
Failed Letdown Valve Shuts down a Urea Plant Several Hours
Discharge Head 3‑monthly leaks of Steam Turbine Driven Centrifugal Compressors
Wrong Operation Internals Destroyed Demineralization Mixed Bed Vessel
Problem with Choked Control Valve with Whisper Trim Cage

Keep Learning

butt weld end Plug Valves Leaks Stopped

PTFE lined 6” 300# butt weld end Plug Valves Leaks Stopped Forever

Industrial Light Fittings and Street Light Poles Corrosion Problems

Industrial Light Fittings and Street Light Poles Corrosion Problems

Packing Compressing Die Set

Carbamate Plunger Pump Packing Problems Eliminated

Tilting Pad Bearing

8000 RPM 8000 kW Turbine Problem

Control Panel Instruments

Control Panel Instruments Problem Threatened Plant Shutdown

Lightning Arrester Bursts Problem

Frequent Feeder-A Lightning Arrester (LA) Bursts – Root Cause Analysis

Transformers Coolers Weld Joints Oil

Transformers Coolers Weld Joints Oil Oozes Were Eye Sores

Innovative Segment Orifice

Pitot-tube Replaced with Innovative Segment Orifice Plate

Discover More

PLC Battery

Everything You Need to Know About PLC Battery

advantages-disadvantages-of-ac-and-dc-power-transmission

Advantages & Disadvantages of AC and DC Power Transmission

Comparison of Flowmeters

Difference between Different Types of Flow Meters

Measurement and Instrumentation Objective Questions

Measurements & Instrumentation Quiz – Set 5

Difference between Transparent Level Gauge and Reflex Level Gauge

Difference between Transparent Level Gauge and Reflex Level Gauge

Electrical Maintenance Engineer's Biggest Enemy

Electrical Components Overheating – Causes, Troubles, Prevent

What is Fail-safe in Siemens PLC?

What is Fail-safe in Siemens PLC?

Difference between Availability, Reliability & SIL

Difference between Availability, Reliability & SIL