Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: NH3 Plant Turbo-compressor Sudden Rise in Temperature
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > NH3 Plant Turbo-compressor Sudden Rise in Temperature

NH3 Plant Turbo-compressor Sudden Rise in Temperature

Root Cause Analysis (RCA): NH3 plant turbo-compressor Tilting Pad too high temperatures sudden affected and entire plant indefinite shutdown threat eliminated.

Last updated: September 28, 2022 3:20 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Root Cause Analysis (RCA): NH3 plant turbo-compressor Tilting Pad too high temperatures sudden affected and entire plant indefinite shutdown threat eliminated.

Contents
ProblemAuthor solution
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:High Speed, Hi KW Major Rotating Machines
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of one or two decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Problem

A turbo-compressor (K-601 T) Tilting Pads’ too high 108 to 110o C close to the 115o C trip pad metal temperature threatened surprise K‑601 T trip and hence total indefinite plant outage.

Author solution

A skilled Japanese technician from the manufacturer working in a neighboring plant suggested scrapping the Babbitt as in fig. However, he declined doing it due to heavy current task deadlines.

Undaunted, the author inspired and guided as under plant crew scraped the pads successfully the very first time.

  1. Grip the pad between 3-mm thick aluminum flats in a vice placed on a lathe bed
  2. Level the pad placing a machinist spirit level across AB (below figure) and tighten up.
  3. Pencil mark axial line CD  2/3 L from A – this view does not show D;
  4. Place a dial gauge on the lathe bed touch point B and zero it.
  5. Scrap the pad along the line BC till point B is 500 µ below point A – checked with the dial gauge – and the surface BC checked axially and along BC with a tri-square.
  6. The pad is ready
NH3 Plant Turbo-compressor Sudden Rise in Temperature

These pads installed in the machine taking a 2‑hour plant shutdown (SD) attained max metal temp 98oC even in hottest ambient temperature summer months, eliminated the K‑601 T trip threat forever, and put all in peace!

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Process Air Compressor Overhauls
  • Compressor Cracked Shaft Spacers
  • Heat Exchanger Root Cause Analysis
  • Compressor Anti-Surge Control RCA
  • Compressor Case Discharge Temperature
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Ammonia Feed Ball Valve to Ship Tank Closed
Centrifugal Compressor Outage Reduced – Root Cause Analysis
Automation Panel Electronic Cards Failure investigation
Heat Exchanger Root Cause Analysis (RCA)
CO2 Absorber Corroded Wall Thickness & Weld Building
Learnings from the BP Refinery Explosion at Texas City
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Pressure Correction Pneumatic Instrumentation
8000 RPM 8000 kW Turbine Problem
Flanged Rotameter Caused Pipe Weld Cracks and Gives Wrong Readings
Leaky Boiler Drum Level Switch Stops NH3 Plant Commissioning
HT motors Corrosion Problem
High-pressure Service Level Transmitters Misunderstood Zero Drifts
Instrumentation Engineering Problems Solved – Root Cause Analysis
A Pipe Elbow Sudden Burst Fatalities and Wrecked Panel Instrumentation

Keep Learning

Damaged Magnetic Flow Meter Flow Tube

None Could Repair Slightly Damaged Magnetic Flow Meter Flow Tube

Rotary Drier Shell to Split Gear drive

Rotary Drier Shell to Split Gear drive eliminates too frequent drive failures

RF and RTJ Flange Installed Gasket

Flange Joint Errors shutdowns root cause analyzed and eliminated

Doubtful Temperature Readings

Doubtful Temperature Readings threatens Soaking Pit Wrecks 

Innovative Segment Orifice

Pitot-tube Replaced with Innovative Segment Orifice Plate

Solving Critical Control Valve Hunting

Solving Control Valve Hunting: Instrument Troubleshooting

Phosphate Dozing System

Phosphate Dozing System Problems

Turbo-Compressor Problem

Turbo-Compressor Problem – Root Cause Analysis

Learn More

How is Data Stored in Standard Modbus Protocol?

How is Data Stored in Standard Modbus Protocol?

4-20 mA Conversion Formulas

Standard 4 to 20 mA Conversion Formula

Power Electronics objective questions and answers

Top 50 Power Electronics Quiz

System architecture

Types of System Architecture used in Industrial Automation

Electrical Wire Mesh

What is an Electrical Wire Mesh?

Learn PLC Programming

Basics of Ladder Diagram in PLC Programming

Dynamic Braking Resistor in VFD

Dynamic Braking Resistor in VFD

Loop Diagram

Documentation and Change Control of PLC or DCS Systems

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?