Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Electrical Cabinet Air Conditioner – Enclosure Cooling, Maintenance
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Electrical Cabinet Air Conditioner – Enclosure Cooling, Maintenance

Electrical Cabinet Air Conditioner – Enclosure Cooling, Maintenance

Learn the electrical cabinet air conditioner cooling methods and the panel enclosure heat dissipation maintenance.

Last updated: March 11, 2024 4:44 pm
Viral Nagda
Electrical Basics PLC Tutorials
No Comments
Share
6 Min Read
SHARE

In an electrical panel, one of the most problem-giving means is heating. As electrical components run inside a panel, they discharge heat over a period of time. This happens due to current consumption and as we know, current throws thermal energy outside when in a large rating.

Contents
Electrical CabinetEnclosure CoolingClosed Loop CoolingHow to Calculate Enclosure Airflow?Enclosure Air Conditioner Maintenance

Electrical Cabinet

Electrical Cabinet Air Conditioner

The heating issue cannot be observed mostly in smaller electrical panels but is observed generally in panels where current consumption is large. Overheating after a period of time can damage the electrical components or burn wires inside.

So, cooling methods must be adopted in electrical panels to control the heat. One such method used in panel cooling is using air conditioners. In this post, we will see the concept of air conditioners in panel enclosures.

Enclosure Cooling

First of all, let us understand why cooling is required in a panel enclosure. As you know, electronic and electrical devices have operating temperature ranges written on their nameplates. When a device is operated in that range, it functions for a good lifetime span.

But, if the device is operated at high temperatures for a long time, it can cause various types of faults like overload, internal burning of components, and breakdown of components. This high temperature is not good for devices inside the panel. Increasing device failures also cause an increase in maintenance costs.

So, cooling methods must be done in panel enclosures to increase the lifetime of devices and maintain the operation under control for a long time. There are many methods to cool a panel like natural convection cooling, forced convection cooling, air conditioning, heat exchangers, vortex cooling, thermoelectric cooling, etc. Out of these, we will discuss air conditioning in this post.

Closed Loop Cooling

Air conditioning is a type of closed-loop control. Basically, it monitors outlet temperature and accordingly, operates the compressor and condenser fans. Usually, condenser fans are on continuously, but the compressor is the one that controls temperature by loading and unloading the refrigerant gas inside the circuit. This gas flow is responsible for efficient heat exchange between inlet temperature and outlet temperature. This same principle works for a panel enclosure AC (air conditioner).

The AC is mounted on the side of the enclosure panel. The temperature inside the panel is monitored continuously. When the temperature rises, the compressor will increase the loading of gas to bring down the temperature, by exchanging hot inside air with the outside air.

When the temperature decreases, the compressor performs unloading of gas to bring the temperature up by exchanging cold air with the outside air. Air must not be too cool or too hot, as any extreme condition can damage the components.

How to Calculate Enclosure Airflow?

Now that our concept of air conditioning is clear, we will see how to calculate the airflow inside the panel for designing the AC circuit.

Consider the following parameters for calculation:

  1. Heat dissipated
  2. Air temperature
  3. Location of the panel
  4. Delta temperature (difference between outside and inner temperature)
  5. Volume of air required at a particular altitude per ºC change

It is necessary to understand that the maximum ambient temperature must always be higher than the maximum enclosure temperature inside. This is because heat exchange takes place by taking cooler air from outside and if the ambient temperature is only hotter, then the heat exchange will not take place effectively.

So, to select the best air conditioner system, the delta temperature must be related to the cooling capacity of the AC unit. If the difference is higher than the cooling capacity, then it means the AC unit will perform within its limit by providing efficient heat exchange.

Enclosure Air Conditioner Maintenance

  1. Always check on a periodic basis whether the delta temperature is higher than the cooling capacity. This will ensure that the AC unit will be able to properly exchange heat with the outside ambient air temperature.
  2. Ensure that the panel is closed properly without any leakages or holes. This will prevent outside dust from entering the panel and also ensure that any air does not leak during the process of refrigeration.
  3. Panels must not be opened frequently. If this is the case, then install a sensor for sensing door opening or closing. Take action on sensing it.
  4. Nowadays, PLC is mostly used inside the AC unit for proper control. Do regular maintenance of the PLC and see to it whether its program is working properly or not.
  5. Filters play a critical role in filtering air dust, dirt, and non-corrosive liquids. Regularly clean the filters.
  6. The most important thing is proper panel wiring. If the wiring and component placing are not done with proper engineering, then cooling will not be effective. So, leave maintenance ahead; first ensure proper panel design and engineering.

Read Next:

  • What is Distributed IO in a PLC?
  • Inputs Sharing Between PLC Systems
  • PLC Multi-Motor Control for Beginners
  • Siemens Communication with I-Device
  • PLC Programming Projects for Beginners
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Dosing Pump PLC Logic
VFD Pros and Cons – Variable Frequency Drives
Troubleshoot Allen Bradley PLC Logic
What are Trends in SCADA?
Auto and Manual Liquid Tank System: PLC Program Example
SCADA Multiple Choice Questions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

OB1 – Main Cyclic Organization Block in TIA Portal
Timers using Statement List (STL) PLC Programming
CX Programmer Example: Perfume Mixing and Filling System
Why Are Charcoal and Salt Added to an Earthing Pit?
How to Convert an Electrical Diagram into PLC Program?
What is Smart or Intelligent MCC?
PLC SCADA Engineers Interview Questions and Answers
Comparison of Proportional Integral Derivative Controllers (PID)

Keep Learning

ICS System Design

ICS System Design Considerations

Open User Communication in Siemens Tia Portal - PLC to PLC

Open User Communication in Siemens Tia Portal – PLC to PLC

PLC Examples for calling functions in SCL

How to Insert Block Calls in SCL Language?

Site Acceptance Test (SAT) of PLC System

PLC System Site Acceptance Test (SAT)

Count the Number of Cartons in a Storage Area PLC Logic

Count the Number of Cartons in a Storage Area PLC Logic

Example of PID Control Instruction

How to Configure PID in Siemens PLC?

PLC Program for Temperature Control using Thermostat

PLC Program for Temperature Control using Thermostat

Timer-based vacuum cleaner in Schneider PLC

Schneider Electric PLC Timer Problem: Vacuum Cleaner

Learn More

electric motor actuator principle

What is a Electric Motor Actuator ?

Transit Time flow meter Theory

Transit Time Flow Meter Principle

Load Cell Assembly

Urea Bagging Plant – Process Flow

PID-Controller-Simulator-graph

PID Controller Tunning Parameters Simulator

HVAC Principle and Theory

Recommendations to HVAC Engineers

Why Do We Need to Connect Transformers in Parallel

Why Do We Need to Connect Transformers in Parallel?

Difference Between Wattmeter and Energy Meter

Difference Between Wattmeter and Energy Meter

Transmitter Performance and Calibration Frequency

How to Calculate Transmitter Performance and Calibration Frequency?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?