Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Multistage Flash Drums Erratic Level Readings
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Multistage Flash Drums Erratic Level Readings

Multistage Flash Drums Erratic Level Readings

Instrumentation engineering root cause analysis of multistage flash drums erratic level instrument readings.

Last updated: September 28, 2022 2:55 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
4 Min Read
SHARE

Instrumentation engineering root cause analysis of multistage flash drums erratic level instrument readings.

Contents
Multistage Flash Drums Erratic Level ReadingsAuthor RCARoot Cause IdentifiedRoot Cause RemovedRoot Cause found solution implementedRoot Cause Solution Benefits
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Sensors
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Multistage Flash Drums Erratic Level Readings

High Pressure (HP) side extended seal diaphragm differential pressure transmitters (DPT) never developed pinholes, unlike the previously discussed urea plant seal DPTs, shop calibrated, and static pressure tests passed before field installation.

Yet the 5-stages flash drums erratic level readings stopped the 750 T/d NH3 commissioning.

Author RCA

Because of drift-free calibration, all differential pressure level transmitters (DPLT) erratic outputs and the excellent brand name the author’ attributed root cause was:

HP, LP or both representative signals did not reach the differential pressure level transmitters (DPLT).  Therefore, he studied the high-pressure (HP) and low-pressure (LP) taps carefully from the vessel drawing and noted the following

  1. The 4” flanged HP extended diaphragm immerses fully in tranquil liquid NH3 contained in each stage chamber. Hence, the DP senses representative HP signal
  2. Welded to the previous stage bottom a 300 mm long extension skirt forms a 150 mm radial width annulus (below figure)
  3. Liquid NH3 from the previous higher pressure stage enters the annulus tangentially – a process requirement
  4. The DPLT LP tap senses the annulus gas pressure
Multistage Flash Drums Erratic Level Readings

Root Cause Identified

He considered these observations and concluded:

  1. The tangential entry and liquid evaporation cause unsteady pulsating annulus pressures
  2. The DPLT LP port senses this pulsating unrepresentative pressures – the erratic liquid NH3 level readings Root Cause disturbances could be causing the DPLTs outputted erratic level signals..

Root Cause Removed

½ hour thought flashed solution was: insert a supplementary nozzle via the LP tap penetrating ½‑extension skirt (above figure) to feed the skirt tranquil pressure to the DPLT LP port.

The diagnosed root cause impressed management ordered, “Go ahead; modify all stages LP taps”, to avoid a second shutdown if this step succeeds.

Root Cause found solution implemented

A crew took the below-listed steps:

  1. They inserted a shop made 100 mm long guide bush in the LP tap and bolted a flange over it
  2. A long drill passing through the guide bush bore drilled 20 mm dia hole in the skirt wall
  3. The crew inserted the shop made supplementary nozzle secured it bolting a flange
  4. Instrument crew connected the supplementary nozzle to the DPLT LP port
  5. Mech and Inst crew did these for all stages

Root Cause Solution Benefits

The DPTs read correctly, as expected, and commissioning progressed rapidly.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Turbine Flow Meter Constraints
  • Pitot-tube Replaced with Orifice
  • Mechanical Temperature Indicator
  • Pressure Transmitter Stopped Working
  • Seal Pressure Instruments Problems
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

Gas Cooler Re-tubing Done Successfully (Root Cause Analysis)
Leaking Plug Valves Pose Safety Hazards and Lead to Plant Shutdown
Automation Panel Electronic Cards Failure investigation
Panel and Field Pneumatic Controller’ Bumpless Transfer Issues
Erratic H2 Flow Rotameter
Alternate 110 KV Connection to Feeder A
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Jackshaft Belt Drive

Poorly Engineered, built & often Failing Plant Air Compressor Drives

Captive Power Plant Trip Root Cause Analysis

Captive Power Plant Trip Root Cause Analysis

NH3 Storage Tanks Ammonia Gas

NH3 Storage Tanks Ammonia Gas Venting Issue – Root Cause Analysis

Burst Transformers Root Cause Analysis

Root Cause Analysis – Burst Transformers and 11 kV Input Breakers

Cooling Water Circulating Pump Low throughput

Cooling Water Circulating Pump Low throughput Resolved

butt weld end Plug Valves Leaks Stopped

PTFE lined 6” 300# butt weld end Plug Valves Leaks Stopped Forever

Boiler Feed Water Heater Shell Flange Leaks

Boiler Feed Water Heater Shell Flange Leaks

Unstable & Drifting Values of Differential Pressure Transmitter

Unstable & Drifting Values of Differential Pressure Transmitter Problem

More Articles

Real-time and historical SCADA Trends

What are Trends in SCADA?

Transistor Biasing

Transistor Biasing

Level Sensors MCQ

Level Sensors MCQ – Industrial Instrumentation

Electric Circuits Objective Questions

Electric Circuits Objective Questions – Set 2

PLC Program for Fishpond Water Level Monitoring System

PLC Program for Artificial Fishpond Water Level Monitoring System

Automation in laboratory

Automating Lab Data Reconciliation: Key Steps to Success

Radio Telemetry Objective Questions

Radio Telemetry Objective Questions

Converter Instruction in Siemens PLC Programming

Converter Instruction in Siemens PLC Programming

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?