Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Passing Control Valves Cause Yearly Losses in Production Plant
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Passing Control Valves Cause Yearly Losses in Production Plant

Passing Control Valves Cause Yearly Losses in Production Plant

Instrumentation engineering root cause analysis (RCA) of control valves passing and they cause yearly losses in a production plant.

Last updated: September 28, 2022 3:02 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Instrumentation engineering root cause analysis (RCA) of control valves passing and they cause yearly 10 million rupees losses in a production plant.

Contents
Passing Control Valves Cause Yearly LossesAuthor SolutionBenefits
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Control Valves
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Passing Control Valves Cause Yearly Losses

The author during his review for improvements after the hectic commissioning problems was over the Table 1 listed 0.5% leak class double seat normally closed vents.

He estimated the control valves (CVs’) leaks cost as Rs 20 million yearly (80s figures).

Tag #Normally closed RFG-Reformed Gas Vents
PCV 125RFG Waste heat boiler
PCV 126RFG CO2 absorber
PCV 127RFG Methanator
PCV 217Urea Plant Vapor NH3  Liq NH3 storage tank
Table 1 Leaky Vent Control Valve Details
Passing Control Valves Cause Yearly Losses

Author Solution

At his request, the vendor quoted 0.1% leak class balanced plug control valve body assemblies that would accept the existing actuators and valve body assembly + actuator for PCV 125.

The cost was hardly $ 2000; the stopped leak savings would pay that in few days. Yet the management stubbornly disapproved.

Finally, he won approval by:

  1. His yearlong relentless persuasive efforts
  2. Demonstrating testbench rotameter measured 1.5% leaks
  3. Impressing the actual leak would be more because of the differential thermal expansion of the carbon steel bodies and SS 316 trim

Benefits

The technical services department confirmed an estimated Rs 100 million saved leak losses after fitting the new valve bodies + old/new actuator assemblies.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Valve Positioners Failed
  • Errors and Faults in Siemens PLC
  • Repeat Failures of Letdown Valves
  • Pressure Taps Block Valves Leaks
  • Unstable & Drifting Values of Transmitter
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Gearbox within week Failing Journal Bearing upset Plant Operations
Gas Cooler Re-tubing Done Successfully (Root Cause Analysis)
Pitot-tube Replaced with Innovative Segment Orifice Plate
Amine Pump Trip – Root Cause Analysis
Leaky Boiler Drum Level Switch Stops NH3 Plant Commissioning
Automation Panel Electronic Cards Failure investigation
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Flange Joint Errors shutdowns root cause analyzed and eliminated
Erratic Radar Level Gauges Delays a Refinery Commissioning
An Indian Plants all turbines’ low Vacuum & Saudi Plant turbo-compressor only
Unreliable Ammonia Flow Transmitter Reading and Problems
Too Low-Temperature Readings after a Failed Thermocouple Change
HT Motor Direction of Rotation (DOR) Changed
How Kalrez O-rings Seal So effectively So Long?
Minimum Oil Circuit Breaker (MOCB) No Vendor Spares & Service

Keep Learning

Arc Fault Breaker (AFB) Electrical Problem Solved

Premature Arc Fault Breaker Failures

Control Valve Plug Stem and Gland Leaks

Repeat Control Valve Plug Stem and Gland Leaks

Cooling Tower Fans Frequently Failing

Cooling Tower Fans Frequently Failing

Refrigeration Compressor Turbine Not-tripping when needed Trip

Refrigeration Compressor Turbine Not-tripping when needed Trip

Rotary Drier Shell to Split Gear drive

Rotary Drier Shell to Split Gear drive eliminates too frequent drive failures

Turbo-Compressor Problem

Turbo-Compressor Problem – Root Cause Analysis

Less than 40% available Plant Air Compressors made available 100%

Less than 40% available Plant Air Compressors made available 100% for Operations

Instrumentation Engineering Root Cause Analysis

Instrumentation Engineering Problems Solved – Root Cause Analysis

Learn More

Interview Questions on Electronics and Instrumentation

Interview Questions on Electronics and Instrumentation

Double-Acting Pneumatic Cylinder Circuit

Pneumatic Cylinder Movement Control with Timer Circuit

Instrument Technician Questions and Answers

Instrument Technician Questions and Answers

Ladder Logic Example of Two Motors

Ladder Logic Example of Two Motors Interlinked with another Motor

HART Multidrop Network

What is HART Protocol ?

Mathematical Models of Physical Systems

Differential Equations of Physical Systems & Dynamics of Robotic Mechanisms

Crowbar fault protection circuit

Crowbar fault protection circuit

PLC Program Upload

How to Upload Siemens PLC Programs?

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?