Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Many Bucket Elevator Wrecks rob crew morale
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Many Bucket Elevator Wrecks rob crew morale

Many Bucket Elevator Wrecks rob crew morale

This article listed excellent features to eliminate the elevator chain wrecks long shutdowns forever.

Last updated: September 28, 2022 3:15 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Root Cause Analysis (RCA): Many Bucket Elevator Wrecks rob crew morale.

Contents
Bucket Elevator WrecksAuthor SolutionEliminate Elevator Chain Wrecks
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Pipelines and Miscellaneous Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Bucket Elevator Wrecks

The obvious root cause was Drive Sprocket Shaft extension mounted improvised and inadequate RRPs did not stop chain reverse rotation on intentional or failed power elevator stops.

The Author Root Cause Analysis identified the improvised RRP inadequacy’s below listed causes:

  1. The sprocket shaft dia is 250 mm; but the shop’s machine could make a RRP for a 100 mm shaft only
  2. Hence, both the shop made RRP and its shaft inserted in a square hole cut in the 250 dia sprocket shaft were inadequate; hence the shaft extension often bent attempting RR preventions
  3. Harsh plant environs contaminating the exposed lubricating grease accelerated the failures

Author Solution

He studied Gearbox (GB) makers’ catalogs and learnt of professionally designed and built GB inside fitted RRPs. They furnish retrofit RRPs too at slight extra cost. Formerly GB high-speed shafts fitted RRPs failed.

Without a Root Cause Analysis they discarded GB fitted RRPs. To satisfy their wishes, the author tried an GB intermediate speed shaft driven RRP.

Its success made the plant fit GB IS driven RRPs for all elevators.

Bucket Elevator Wrecks

Eliminate Elevator Chain Wrecks

Substituted RRPs excellent features

The below listed excellent features eliminate the elevator chain wrecks long shutdowns forever:  

  1. By design and manufacture their torque ratings meet plant needs
  2. Dust and water tight enclosure protects the RRP from the plant’s corrosive and dusty environs
  3. Copious uncontaminated oil supply besides lubrication cools the RRP also
  4. The improvised grease lubricated RRP lacked this feature

Vanished elevator wrecks delighted all.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Plug Valves Leaks
  • Rupture Discs bursts
  • Repeat Safety Valve Popping
  • Fan Bearing Change Times cut by 90%
  • Boiler Feed Water Shell Flange Leaks
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Root Cause Analysis of Differential Pressure Level Transmitter
Transformers Coolers Weld Joints Oil Oozes Were Eye Sores
Primary Reformer – Each Turnaround done expensive Tubes Repairs
Root Cause Analysis for Tank Overflow due to Valve Problem
Repeat Control Valve Plug Stem and Gland Leaks
Pipeline Shakes Torn apart Valve Positioners
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

A Plant Bucket Elevators chains too short chain lives problem eliminated
Incident Investigation: Motor Operated Valve Lesson
A Large Gate Valve’s Failed Motorized Operation
Fired Boiler Induced Draft Fan (IDF) Failures Upset all Plants Operations
Poorly Engineered, built & often Failing Plant Air Compressor Drives
Fasteners and General Corrosion of Electrical Motors
Recurring Short Circuit Flash Overs Safety Hazards & Damages
Cement kilns, Rotary Drum Driers Simplest Electrical Drive
Amine Pump Trip – Root Cause Analysis
Hunting of Control Valves

Keep Learning

Pump Mechanical Seal and thrust bearing Problem

Pump 3-monthly Seal Leaks threaten entire Plant Shut down Indefinitely

HT motors Corrosion Problem

HT motors Corrosion Problem

butt weld end Plug Valves Leaks Stopped

PTFE lined 6” 300# butt weld end Plug Valves Leaks Stopped Forever

BP Refinery Explosion

Learnings from the BP Refinery Explosion at Texas City

Cooling Water Circulating Pump Low throughput

Cooling Water Circulating Pump Low throughput Resolved

Reformer Fan Bearing Change Times cut by 90%

Reformer Fan Bearing Change Times cut by 90%

Turbine to Gearbox Alignment Drifts Caused Pump Transfers Problems

RCA Related to Trip Throttle Valve (TTV)

Alternate 110 KV Connection to Feeder A

Alternate 110 KV Connection to Feeder A

Discover More

Dew Point Meter Principle

Dew Point Meter Principle

Instrumentation and Control Engineer Subject

Competency Factors of Instrument & Control Engineer (Design Engineering)

Electrical Machines Questions and Answers

Synchronous Machine Quiz

Types of Sensors Used in Automobiles

Types of Sensors Used in Automobiles

Level-Measuring-Instruments-Velocities-of-Propagation

Level Measuring Instruments Velocities of Propagation

Demister Pads Problem

Problems with Demister Pads – Root Cause Analysis (RCA)

Ultrasonic Transmitters vs. Guided Wave Radar Transmitters

Ultrasonic Transmitters vs Guided Wave Radar for Level Measurement

Digital Electronics Multiple Choice Questions

Half Subtractor and Full Subtractor Objective Questions

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?