Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: PTFE lined 6” 300# butt weld end Plug Valves Leaks Stopped Forever
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > PTFE lined 6” 300# butt weld end Plug Valves Leaks Stopped Forever

PTFE lined 6” 300# butt weld end Plug Valves Leaks Stopped Forever

Root Cause Analysis (RCA): Urea Plant tight shut off impossible PTFE liner 6” 300# butt weld end Plug Valves leaks stopped.

Last updated: September 28, 2022 3:15 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
2 Min Read
SHARE

Root Cause Analysis (RCA): Urea Plant tight shut off impossible PTFE liner 6” 300# butt weld end Plug Valves.

Contents
Author ObservationAuthor Solution
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Pipelines and Miscellaneous Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Author Observation

He disassembled the heaviest passing valve. A steel scale showed dented taper – the cause of the leak.

Obviously, the 6 mm wall thickness hollow plug caves in under closed condition line condensate pressure; hence the leaks

Author Solution

On his insistence, the vendor after few futile repair attempts furnished solid taper plugs. Passing Problems vanished forever.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Leaking Plug Valves
  • Flange Joint Problems
  • Pipe Elbow Sudden Burst
  • Fan Motor Journal Bearing Failures
  • Fired Boiler Induced Draft Fan Failures
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Readers Questions on Flow Transmitter
11 KV Bus A to Bus B Phase Check Problem
[RCA] Pump Low throughput Eliminated
A Plant Bucket Elevators chains too short chain lives problem eliminated
CO2 Absorber Corroded Wall Thickness & Weld Building
Bucket elevators Chain and teeth wear Problems
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Too Low Efficiency Torque Converter Elimination Attempt
Flange Joint Errors shutdowns root cause analyzed and eliminated
Erratic Radar Level Gauges Delays a Refinery Commissioning
Compressor IP Case Discharge Temperature Gradually Increases
Wrong Operation Internals Destroyed Demineralization Mixed Bed Vessel
Critical High KiloWatt Motor Winding Burnout Threats
Magnetic Flow Meter Liner Damaged and Winding Burnt
Unstable & Drifting Values of Differential Pressure Transmitter Problem
Ammonia Feed Ball Valve to Ship Tank Closed
11 kV, 3.3 kV, and 400 V systems insulation resistance (IR) Problems

Keep Learning

Compressor Cracked Shaft Spacers

Compressor Cracked Shaft Spacers

Centrifugal Compressor Shaft Vibrations Problem

Centrifugal Compressor near ½-RPM Frequency High Magnitude Shaft Vibrations

Target Flow Transmitter Problem

Unreliable Ammonia Flow Transmitter Reading and Problems

Jacket Added Seawater Pipe Spool

Seawater Pipeline Spools from day-1 leaks threaten Plant Shutdown

Rotary Drier Shell to Split Gear drive

Rotary Drier Shell to Split Gear drive eliminates too frequent drive failures

Pulverizer Electrical Problem Solved

Pulverizer Electrical Problem Solved

Vac Residue Tank Electrical Heating Element

Poor Electrical Heating Element Lives – Problem Solved

Fasteners and General Corrosion of Electrical Motors

Fasteners and General Corrosion of Electrical Motors

Discover More

Feedforward control with feedback trim

Feedforward Control Principle

Instrumentation in Industries

Why is Instrumentation used in Industries?

Time Response Analysis

Approximation of Higher-Order Systems by Lower Order

Underground Cable Fault Identification Methods

Reformer Fan Bearing Change Times cut by 90%

Reformer Fan Bearing Change Times cut by 90%

Component De-rating

Component De-rating in Control Systems

Distributed IO for Siemens PLC

How to Configure Distributed IO in a PLC Project?

Control Valve Tubing

Instrument Tube Bending

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?