Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Fan Motor Frequent Journal Bearing Failures Posed Plant Outages
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Fan Motor Frequent Journal Bearing Failures Posed Plant Outages

Fan Motor Frequent Journal Bearing Failures Posed Plant Outages

Root Cause Analysis (RCA): 450 KW 1500 RPM plant fan motor frequent Journal Bearing failures posed plant outages.

Last updated: September 28, 2022 3:19 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
4 Min Read
SHARE

Root Cause Analysis (RCA): 450 KW 1500 RPM plant fan motor frequent Journal Bearing failures posed plant outages.

Contents
Fan Motor Frequent Journal Bearing FailuresImplemented RCA solutionPermanent Solution
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Miscellaneous Rotating Machine Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Fan Motor Frequent Journal Bearing Failures

A new installation 450 KW 1500 RPM motor Journal Bearing (JB) failed too often. The author RCA Queries (Q) and crews’ answers (A) are:

Q: Describe failed bearing condition

A: JB side babbit blacked and peeled off

Few minutes thinking flashed the probable RC:

  1. Indigenous Tire Couplings use for such large drives is new to the crew
  2. Maybe they did not adjust the coupling halves face‑to‑face length correctly
  3. Hence, probably the tire coupling did not allow the motor rotor settling at the magnetic center, the shaft collar rubbed the Journal Bearing (JB) side & destroyed the babbitt.    
  4. In addition, maybe all tires are not of equal width (below figure). Checking this is necessary.
Fan Motor Frequent Journal Bearing Failures

Crew reported they checked the warehouse held six tires widths and found they vary as much as 6 mm. The coupling vendor accepted that is how tires are; hence our instruction manual says adjust the coupling face to face gap at each tire change to suit the tire width.

The author concluded crew remembering tire couplings’ unique requirement is hard and mistakes recurrences, more JBs damages, and frequent downtimes are too easy also.

Implemented RCA solution

Implemented RCA solution follows:

  1. He got the motor coupled taking care of the distance between coupling halves = tire width with the rotor at the magnetic center. 
  2. This enabled quick plant starts.
  3. During fortnightly housekeeping ½ shift SDs, crew ensured step 2 with the other two motors and averted likely failures

Permanent Solution

The author recalled that German make Pin and bush couplings (PBCs) coupling the carbamate and liquid ammonia feed pumps to same motors types never posed problems during their 10 years’ service. They allow the JB motors rotors axial travels.

The author made the shop to make Pin & Bush couplings using the plant PBC as model. The machinist took essential dimensions from the standby pump’s coupling in the field with proper work permits, from the spares held in stock to machine the 3 Nos., couplings.

A local rubber parts maker made bushes using the spare bushes as model. PBCs in place of Tire-couplings eliminated the problems forever.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Turbo-Compressor Problem
  • Compressor Anti-Surge Control
  • Plant Air Compressors Problems
  • Plant Turbo-compressor Problem
  • Failing Plant Air Compressor Drives
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Incident Investigation: Motor Operated Valve Lesson
Aluminum Cable Terminations Repeat Failures
Erratic H2 Flow Rotameter
Cooling Tower fan FRP fan blades saves and saves
Pitot-tube Replaced with Innovative Segment Orifice Plate
HT Motor Problem appears after Disassembly and Reassembly
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

PTFE lined 6” 300# butt weld end Plug Valves Leaks Stopped Forever
Primary Reformer RFG main Hot Spots threaten Indefinite Outage
RCA Related to Trip Throttle Valve (TTV)
Poorly Engineered, built & often Failing Plant Air Compressor Drives
A Pipe Elbow Sudden Burst Fatalities and Wrecked Panel Instrumentation
Solenoid Valve Failure in Plant Start-Up: Identifying the Root Cause
Thermocouple Wires and Extension Lead Issues
Control Panel Instruments Problem Threatened Plant Shutdown
Passing Control Valves Cause Yearly Losses in Production Plant
Pipeline Shakes Torn apart Valve Positioners

Keep Learning

Erratic Radar Level Gauges

Erratic Radar Level Gauges Delays a Refinery Commissioning

Bently Nevada Proximity Probe

Root Cause Analysis for Vibration Probe Not Responding

NH3 Plant Turbo-compressor Sudden Rise in Temperature

NH3 Plant Turbo-compressor Sudden Rise in Temperature

ISO 5167 Orifice Plate Types

Readers Questions on Flow Transmitter

Root Cause Analysis of Differential Pressure Level Transmitter

Root Cause Analysis of Differential Pressure Level Transmitter

Valve Actuator Passing

Lessons Learned from Actuator Passing Incidents

Plunger Pump

Within Few Weeks Failing Acid Dozing Pumps

Captive Power Plant Trip Root Cause Analysis

Captive Power Plant Trip Root Cause Analysis

Discover More

Ion Analyzers Questions and Answers

Ammonia and Fluoride Electrode Questions & Answers

Configure Analog Inputs and Outputs in Delta PLC

How to Configure Analog Inputs and Outputs in Delta PLC?

EcoStruxure Machine Expert - HVAC - Programming Software

How to Write a Program in Ecostruxure Machine Expert HVAC Software?

Valve Seat leakage Test

Valve Seat Leakage Test

How To Choose A Surge Protector?

How To Choose A Surge Protector?

Free Electronics Software Download

MOSFET VI Characteristics

Power MOSFET

Chromatography Questions & Answers

Gas Solid Chromatography Questions & Answers

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?