Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Why Viscosity is Not Included in the Orifice Equation?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > Why Viscosity is Not Included in the Orifice Equation?

Why Viscosity is Not Included in the Orifice Equation?

Has this question troubled you that viscosity is not included in the Orifice equation? This article explains importance of Reynolds number.

Last updated: November 2, 2023 12:10 pm
Editorial Staff
Flow Measurement
No Comments
Share
2 Min Read
SHARE

Has this question troubled you that viscosity is not included in the Orifice equation?

Contents
Orifice PlateDemystifying Reynolds Number

Orifice Plate

Imagine Honey flowing through the pipe and on the contrary water flowing through the Pipe will have the same pressure drop. You have guessed it right the pressure drop won’t be the same.

So why is viscosity not in the equation? This question puzzled Tony Rudolph for 15 years until he had an Eureka moment.

Demystifying Reynolds Number

We owe Sir Osborne Reynolds for this discovery.

To understand this let’s take a simple example.

Imagine we pour honey and water on a slide.

Who will reach first?

Viscosity in Orifice equation

Water will reach down first as compared to honey.

Why?

The answer in simple words is water has a lesser tendency to stick along its surface as compared to Honey.

This phenomenon is captured in Reynolds number.

Formula of Reynolds Number

The “Numerator” consists of 3 variables that could be termed together as Inertial force.

V=Velocity, D=Diameter, p=density

The “Denominator” consists of one term and that is absolute viscosity.

Hence, in conclusion, the Reynolds number is the ratio of “Inertial forces” to “Viscous force”.

So higher the Reynolds number the more “Inertial forces” dominate.

And for orifice meter one of the requirements is a high Reynolds number.

Thus as “Viscous forces” at very high Reynolds are negligible we don’t consider them in the equation.

Thanks for reading.

I hope it’s been of value to you.

Credits: I stumbled upon this insightful concept in Tony R Kuphaldt book “Lessons In Industrial Instrumentation”. A great read.

Author: Asad Shaikh

Profile: Linkedin

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Vent and Drain Holes of Orifice
  • What is Orifice Beta Ratio?
  • Orifice Meters Compensation
  • What is Restriction Orifice?
  • Turndown ratio of Orifice 
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

DP Flow Transmitter Re-Ranging Calculation
Basics of Flow Measurement
Continuous Flow Measurement
Magnetic Flow Meters Installation Guidelines
Importance of Magnetic Flow Meters Grounding
What is a Torbar? – Averaging Pitot Tubes
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Differential Pressure (DP) Flow Meters Range Calculation Methods
Step by Step Guide for Gas Flow Meter Calibration
Bernoulli’s Principle and Equation – Flow Measurement
Metal Tube Variable Area Flow Meters Principle
Orifice Plate Turndown ratio
Flow Instruments – Selection, Principle & Application
Why Orifice Flow Meter Flange is Not Recommended 150# Rating?
Difference between Transit time and Doppler Ultrasonic Flow Meter
Electro-Magnetic Flow meter Objective Questions
Spring Loaded Variable Area Flow Meter Working Principle

Keep Learning

Lobed Impeller Flow Meters Working Principle

Lobed Impeller Flow Meters Working Principle

Turbine Flow Meter

All About Turbine Meters

Coriolis Mass Flowmeter Principle

Coriolis Mass Flow Sensor Theory

Flow Measurement Objective Questions

Flow Measurement Objective Questions

microwave flow detector applications

Microwave Flow Sensor – Working Principle and Applications

Orifice Taps

Orifice Plate Tapping – Orifice Plate Taps

Reasons to Calibrate Flowmeters

Reasons to Calibrate Different Types of Flow Meters

DP type Flow Transmitter Preventive Maintenance

Troubleshooting DP type Transmitter Common Problems

Discover More

Calculate Temperature of Three Wire RTD

Determine the Temperature of 3 Wire RTD

DC Generator

DC Generator

Applications of Electrical Conduit System

What is an Electrical Conduit? – Types – How to Choose?

Material Certificate versus Positive Material Identification (PMI)

Material Certificate versus Positive Material Identification (PMI)

Structured Text PLC Program for Sequential Process Data Storage

Structured Text PLC Code for Sequential Process Data Storage

dead-weight-tester-principle

What is a Dead Weight Tester?

Omron PLC programs

Daily Alarm PLC Program using Real-Time Clock

Valve Software

Free Control Valve Software Download

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?