Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Turbine Flow Meter Coefficient and Scaling Factor
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > Turbine Flow Meter Coefficient and Scaling Factor

Turbine Flow Meter Coefficient and Scaling Factor

Turbine flowmeter generates 10 pulses per gallon of liquid passing through it. Determine the meter coefficient and calculate the scaling factor.

Last updated: November 2, 2023 10:01 am
Editorial Staff
Flow Measurement Formulas
No Comments
Share
1 Min Read
SHARE

A digital turbine flowmeter generates 10 pulses per gallon of liquid passing through it.

Determine the meter coefficient and calculate the scaling factor that is needed to develop an output in which each pulse would represent 100 gallons.

Turbine Flow Meter Scaling Factor

Solution:

The meter coefficient is as follows:

Turbine Flow meter coefficient

K = Pulses / Volume

so as per above inputs, K = 10 Pulses / gallon

The scaling factor is as follows:

 = (10 pulses/gallon) x (100 gallons)

= 1000 pulses

Therefore, a scaling factor of 1,000 is necessary to ensure that the flowmeter’s digital circuit generates one output pulse for every 1,000 pulses generated by the magnetic pickup coil.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Vortex Flow Meter Principle
  • Dall Tube Flow Meter Principle
  • Flow Meter Verification
  • MPFM Working Principle
  • Flow Transmitter Questions
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

What is Water Cut Meter?
Basics of Flow Measurement
Coriolis Flow Meter Construction
Change-of-Quantity Flow Measurement
Turbine Flow Meters Animation
4-20mA Linear Conversion Calculation for VFD Drive (Formula)
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What is Differential Pressure Flow Meter?
Wedge Flow Meter Principle
Pressure based Flow Meters
4-20mA Transmitters Calculations
Coriolis Mass Flow Meter as a Multi-Variable Transmitter
Calculate Process Variable from 4-20mA using Fraction of Measurement
Flow Meter Calibration
Dall Tube Flow Meter – Principle, Advantages, Disadvantages

Keep Learning

Coriolis Mass Flow meter as a Multi Variable Transmitter - 2

Coriolis Flowmeter Advantages and Limitations

Insertion flow meters

What is an Insertion Flow Meter? – Types, Principle, Advantages

Calculate PV Value

Calculate Process Variable from Transmitter Current

Instrumentation Impulse Lines

All About Instrumentation Impulse Lines

Target Meter Principle

Target Flow Meter – Working Principle, Advantages, Disadvantages

Flow Measurement Questions and Answers

80+ Flow Measurement Interview Questions and Answers

Coriolis Mass Flow Meter Verification Procedure

Prover Tank Calibration and Mass Flow Meter Verification Procedure

Level Calculation with Remote Seals

Level Calculation with Remote Seals

Learn More

V Cone Flow Meter Working Principle

V Cone Flow Meter – Principle, Advantages, Disadvantages

Electric Circuits Objective Questions

Electric Circuits Objective Questions – Set 7

VHDL Projects for Engineering Students

100 VHDL Projects for Engineering Students

Tuning Fork Level Switch principle

Tuning Fork Level Switch Principle

Importance of Fire & Gas Detection System

Importance of Fire & Gas Detection System

caliper metrology tool

An Overview of Metrology Tools for CNC Machining

General Specification of Thermowell

General Specification of Thermowell

Fisher model 546 I to P transducer

Fisher model 546 I/P transducer

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?