Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: SIS Safety Requirements
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Safety Instrumented System (SIS) > SIS Safety Requirements

SIS Safety Requirements

Functional safety engineers consider these SIS requirements while designing safety instrumented systems and safety functions.

Last updated: May 23, 2022 8:34 am
Editorial Staff
Safety Instrumented System (SIS)
No Comments
Share
6 Min Read
SHARE

In Safety Instrumented System (SIS), safety requirements follow the specifications prescribed in the below sections.

These requirements shall be sufficient to design the SIS and shall include a description of the intent and approach applied during the development of the SIS safety requirements as applicable.

SIS Safety Requirements

Functional Safety Engineering

SIS safety requirements follow the general norms prescribed below.

  • Safety Requirements Specification – Describes the function of the protective layer & Provides design details.
  • Safety Requirements Specifications are taken from – LOPA, Team members involved in safety design
  • Safety Requirement Specifications documented in – Safety Requirements Specification detailed documentation, Safety Requirements Specification (SRS) form, LOPA database, or workbooks.
  • SIF description of all the necessary LOPA scenarios with required logic to achieve the required functional safety (e.g., a cause and effect diagram, logic narrative)
  • Assumed sources of demand and demand rate on each SIF.
  • Process plant input and output devices list related to each SIF which is identified by the plant by means of equipment identification (e.g., field tag list) and all of them marked in P&ID.
  • List the requirements to identify and take account of common cause failures,
  • Define the safe state of the process for each identified SIF, elaborate on a  steady state to be achieved and the specified hazardous event has been avoided or sufficiently mitigated
  • Definition of any individually safe process states which, when occurring concurrently, create a separate hazard (e.g., overload of emergency storage, multiple relief to flare system);
  • Requirements detailing the proof test intervals
  • Requirements relating to proof test implementation
  • Response time requirements for each SIF to bring the process to a safe state within the process safety time
  • Describe all SIS elements –  process measurements, range, accuracy, and their trip set points
  • List SIF process output actions and the criteria for successful operation, e.g., Allowable seat leakage rate for final control element on/off valves
  • The functional relationship between process inputs and outputs, including logic, mathematical functions, and any required permissive for each SIF including the time constants, correction factors for input sensors, etc.
  • List the requirements for manual shutdown for each SIF
  • List all requirements relating to energize or de-energize to trip for each SIF;
  • Describe the requirements for resetting each SIF after an emergency shutdown (e.g., requirements for manual, semiautomatic, or automatic final element resets after trips
  • Update the maximum allowable spurious trip rate for each SIF
  • Narrate all failure modes for each SIF and desired response of the SIS (e.g., alarms, automatic shutdown)
  • List the required SIL and mode of operation (demand/continuous) for each SIF
  • Explain any specific requirements related to the procedures for starting up and restarting the SIS.
  • Description of the modes of operation of the plant and requirements relating to SIF operation within each mode;
  • Application program safety requirements as listed in relevant safety documentation.
  • Define the requirements for bypasses including written procedures to be applied during the bypassed state that describes how the bypasses will be administratively controlled and then subsequently cleared
  • List all interfaces between the SIS and any other system (including the BPCS and operators);
  • Specify the requirements of Operator response to alarms.
  • Specify any action necessary to achieve or maintain a safe state of the process in the event of a fault(s) being detected in the SIS, taking into account all relevant human factors and the mean repair time which is feasible for the SIS.
  • Ensure to take into account travel time, location, spares availability, service personnel availability, and environmental constraints
  • Identify all of the dangerous combinations of output states of the SIS that need to be avoided
  • Identify all extremes of environmental conditions that are likely to be encountered by the SIS during shipping, storage, installation, and operation. This may require consideration of the following: temperature, humidity, contaminants, etc. Besides electrical grounding, electromagnetic interference/radio frequency interference (EMI/RFI), shock/vibration, electrostatic discharge, electrical area classification, flooding, lightning, and other related factors are to be taken in mind.
  • Identify normal and abnormal process operating modes for both the plant as a whole (e.g., plant start-up) and individual plant operating procedures (e.g., equipment maintenance, sensor calibration, or repair). Additional SIFs may be required to support these process operating modes.
  • Define the requirements for any SIF necessary to overcome any major accident event, e.g., the time required for a valve to remain operational in the event of a fire.

Conclusion

SIS designers/reviewers to consider the above requirements while designing Safety Instrumented systems and Safety Functions. This helps for robust SIS for the safe operation of plant facilities.

If you liked this article, then please subscribe to our YouTube Channel for Electrical, Electronics, Instrumentation, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Audit & Assessment in SIS
  • SIS Hardware Fault Tolerance
  • ERP in Industrial Automation
  • Bypass and Impairment in SIS
  • SIS Testing and Repair Deferral
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

What is a Logic Solver? – Safety PLC
Functional Safety Questions & Answers
SIS Design – Safety Instrumented System
Understanding Safety Integrity Level IEC 61511
SIS Solenoid Valves – Safety PLC
ESD System Insights: Signals for Emergency Valve Shutdown Explained
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What is Shutdown Valve?
What is Burner Management System (BMS)?
Understanding Emergency Shutdown Button Installation (ESD)
SIS – Safety Instrumented System Example
Safety Requirement Specifications (SRS) – Safety Instrumented System
Safety Instrumented System Engineer Interview Questions
SIS PFD – Safety Instrumented System
Intrinsic Safe Calculation
What is High Integrity Pressure Protection System?
SIS Component Selection – Safety Instrumented System

Keep Learning

P&ID

Over Pressure Protection Devices

SIS Failures and Reliability - Safety Instrumented Systems

SIS Failures and Reliability – Safety Instrumented Systems

trip solenoid installed on a control valve appears

SIS Final Control Elements

pressurized water reactor

SIS Example : Nuclear Reactor Controls

transmitters shared for BPCS and SIS

SIS Instrument Sharing – Transmitters Shared for BPCS and SIS Example

Common Cause Failure in Safety Instrumented System

Common Cause Failure – Safety Instrumented System

Voting Logic in Safety Instrumented System (SIS)

Voting Logic in Safety Instrumented System (SIS)

Basics of Emergency Shutdown System

Emergency Shutdown System Philosophy

Discover More

Measurement and Instrumentation Objective Questions

Measurements & Instrumentation Quiz – Set 3

Cascade Control System

Cascade Control

RSLogix5000 PLC Program Backup procedure

Capacitive Level Measurement Principle

Capacitive Level Measurement

Identify Valve Parts Quiz with Answers

Identify Valve Parts Quiz with Answers

Turbine Flowmeter Parts

What is a Turbine Flow Meter?

Differential Pressure Switch Principle

Differential Pressure Switch Principle

Card Failures in Automation Panels

Automation Panel Electronic Cards Failure investigation

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?