Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > None Could Repair Slightly Damaged Magnetic Flow Meter Flow Tube

None Could Repair Slightly Damaged Magnetic Flow Meter Flow Tube

Instrumentation engineering root cause analysis of slightly damaged magnetic flow meter tube and none of them could repair them.

Last updated: September 28, 2022 2:51 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Instrumentation engineering root cause analysis of slightly damaged magnetic flow meter tube and none of them could repair them.

Contents
Damaged Magnetic Flow Meter Flow TubeAuthor RepairRecurrence EliminatedBenefits
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Instruments
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Damaged Magnetic Flow Meter Flow Tube

All pipeline re-liners declining to reline or repair the 1½” Magnetic flow meter head flow tube end lining threatened junking the entire high cost imported head.

Author Repair

The author repaired the flow tube thus:

  1. Let the re-winder re-wind as the burnt winding
  2. Dressed the damaged liner even
  3. Tight fitted a shop made filled PTFE sleeve to make up the last lining
  4. Tight fitted a shop made 50-mm long carbon filled PTFE bush covering the sleeve and overlapping the liner. Bush collar dia = flow tube metal collar dia
  5. Assembled the rewound windings over the flow tube; The head is ready for calibration
  6. The head calibrated as described in the next problem worked fine several years.
Damaged Magnetic Flow Meter Flow Tube

Recurrence Eliminated

Fortunately, the Magmeters were 1 size smaller than pipeline size for higher velocities through the meter to avoid liquid carried particles depositing.

Hence, they came mounted between flanged SS pipeline reducers. The author strictly instructed the crew to unbolt both ends reducers to pipes flanges.

This way magmeters suffered no end lining damages ever.

Benefits

Author Repair Benefits are:

  1. Enabled production reduction within 8-hours and met the committed orders
  2. Besides the financial gains, it  preserved image as a reliable phosphate fertilizer supplier
  3. Saved a head purchase costs
  4. Found a way to handle future such problems

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Pressure Switch Screwed Cover
  • Doubtful Temperature Readings
  • Pressure Switch Screwed Cover
  • Level Instruments Stopped Working
  • Thermowell Shank to Flange Leaks
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Discharge Head 3‑monthly leaks of Steam Turbine Driven Centrifugal Compressors
Under and Over-Capacity Control Valve Pose Poor Controllability
Repeat Control Valve Plug Stem and Gland Leaks
Seawater Pipeline Spools from day-1 leaks threaten Plant Shutdown
Rupture Discs bursts caused too many Urea Plant Shutdowns
Rotary Drier Shell to Split Gear drive eliminates too frequent drive failures
Share This Article
Facebook Copy Link Print
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

30 Electrical Engineering Problems – Root Cause Analysis
Condensate Pump Frequent Wrecks Threatens Long Plant Outages
Repeat Safety Valve Popping caused Urea Plant Shutdown
Magnetic Flow Meter Liner Damaged and Winding Burnt
Control Valve Passing Problem after Overhauling Job
Captive Power Plant Trip Root Cause Analysis
Premature Arc Fault Breaker Failures
Wrong Operation Internals Destroyed Demineralization Mixed Bed Vessel
Root Cause Analysis for Plant Trip Due to Work on Incorrect Tag
Fired Boiler Induced Draft Fan (IDF) Failures Upset all Plants Operations

Keep Learning

Compressor Cracked Shaft Spacers

Compressor Cracked Shaft Spacers

Pump Mechanical Seal and thrust bearing Problem

Pump 3-monthly Seal Leaks threaten entire Plant Shut down Indefinitely

Boiler Feed Water Heater Shell Flange Leaks

Boiler Feed Water Heater Shell Flange Leaks

Demister Pads Problem

Problems with Demister Pads – Root Cause Analysis (RCA)

Leaky Boiler Drum Level Switch

Leaky Boiler Drum Level Switch Stops NH3 Plant Commissioning

Poorly Built Switchgears

Poorly Built Switchgears – Why Breaker Parts Tear apart or don’t work?

Erratic H2 Flow Rotameter

Erratic H2 Flow Rotameter

Steam Pressure Taps Primary Block Valves Glands and Bonnets Leaks

Instrument Steam Pressure Taps Primary Block Valves Glands and Bonnets Leaks

Discover More

Polyphase Induction Motor Multiple Choice Questions and Answers

200+ Polyphase Induction Motor Multiple Choice Questions and Answers

Pressure Correction Pneumatic Instrumentation

Pressure Correction Pneumatic Instrumentation

Full Wave Bridge Rectifier Operation

Full Wave Bridge Rectifier Operation

PLC Timer Programming Examples – TON, TOF, TP and TONR

Schneider PLC Programming Example

Schneider PLC Programming Example for Beginners

Rotary Drier Shell to Split Gear drive

Rotary Drier Shell to Split Gear drive eliminates too frequent drive failures

VFD Torque Boosting

What is Torque Boosting in Variable Frequency Drive (VFD)?

Pressure Gauge Datasheet Preparation

How to Prepare Pressure Gauge Datasheet ?

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?