Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: CO2 Stripper Old Differential Pressure Transmitter Stopped Working
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > CO2 Stripper Old Differential Pressure Transmitter Stopped Working

CO2 Stripper Old Differential Pressure Transmitter Stopped Working

CO2 stripper old pneumatic differential transmitter stopped working and delays the plant commissioning progress.

Last updated: September 28, 2022 2:56 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Instrumentation engineering root cause analysis (RCA) of CO2 stripper pneumatic differential transmitter stopped working and delays the plant commissioning progress.

Contents
Differential Pressure Transmitter Stopped WorkingAuthors Root Cause AnalysisAuthor Final solutionRealized Benefits
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Transmitters
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Differential Pressure Transmitter Stopped Working

The CO2 stripper 5 beds Differential Pressure transmitters (DPT) stopped working within few minutes and it delays the NH3 plant commissioning progress.

CO2 Stripper Old Differential Pressure Transmitter Stopped Working

Note: This is a Pneumatic based differential pressure transmitter

Authors Root Cause Analysis

The author traced the problem to the stripper gas carried over water filling both differential pressure transmitters (DPT) leads within few minutes.

Zero suppressing for the short-height high-pressure lead is easy (as shown in the above figure).

On the other hand, no DPT offered zero elevation capability for the 20 m tall LP lead. Even the added 10 Liters LP lead bottom fitted cylinder and the entire LP lead-filled within few minutes.

The process licensor gave up the problem unsolvable.

Author Final solution

The above figure is shown 1:1 pneumatic relay (PRESSURE) was the answer: it senses the LP tap pressure and outputs equal air pressure to the LP: Port.

Zero elevation is not necessary as 1.293 Kg/Nm3 air density is negligible compared to 1000 Kg/m3. water density. Crew zero suppressed for the HP fill.  

Shop made process wetted SS-316 parts replaced the 1:1 relay process incompatible brass parts. A 0.8 mm thick PTFE disc prevents the process wetting the PRESSURE process side diaphragm; hence it lasts forever.

Realized Benefits

Realized Benefits are:

  1. Each tray reliable ▲P measurement let commission progress to completion
  2. It helps the process fine tuning
  3. A DDUDP solved at negligible costs and time

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Butterfly Valve Failure
  • Actuator Diaphragm Bursts
  • Control Valves Leak Tightness
  • Over-Capacity Control Valve
  • Control Valve Gland Leaks
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Serious Constraints Prevent using an Available Turbine Flow Meter
Repeat Failures of Letdown Valves
[RCA] Pump Low throughput Eliminated
Recurring Short Circuit Flash Overs Safety Hazards & Damages
Butterfly Valve Failure Caused Serious vicinity Heavy Fire
Thermocouple Wires and Extension Lead Issues
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Pump 3-monthly Seal Leaks threaten entire Plant Shut down Indefinitely
Primary Reformer – Each Turnaround done expensive Tubes Repairs
Cement kilns, Rotary Drum Driers Simplest Electrical Drive
Miscellaneous Electrical Tasks – Repaired Reformer Tubes Weld Stress Relief
Inability to Test Repaired HT Motors in Workshop Posed Problems
Seal Pressure Instruments Root Cause Analysis
Poor Electrical Heating Element Lives – Problem Solved
Problems with Demister Pads – Root Cause Analysis (RCA)
Magnetic Flow Meter Liner Damaged and Winding Burnt
Fired Boiler Induced Draft Fan (IDF) Failures Upset all Plants Operations

Keep Learning

Leaking Plug Valves pose Safety Hazards and Lead to Plant Shutdown

Leaking Plug Valves Pose Safety Hazards and Lead to Plant Shutdown

Arc Fault Breaker (AFB) Electrical Problem Solved

Premature Arc Fault Breaker Failures

Cooling Tower Fans Frequently Failing

Cooling Tower Fans Frequently Failing

RF and RTJ Flange Installed Gasket

Flange Joint Errors shutdowns root cause analyzed and eliminated

Control Panel Instruments

Control Panel Instruments Problem Threatened Plant Shutdown

A Large Gate Valve Failed Motorized Operation

A Large Gate Valve’s Failed Motorized Operation

HT motors Corrosion Problem

HT motors Corrosion Problem

Bucket Elevator Wrecks

Many Bucket Elevator Wrecks rob crew morale

Discover More

Temperature Controller

What is a Temperature Controller? – How to Choose?

Falling Positive and Falling Negative Instructions in PLC

Positive and Negative Edges using Statement List Language

Convert Raw Counts to Engineering Units

Raw Counts to Engineering Units : Conversion Formula

Analyzers Questions and Answers

Pulse Height Analyzer Questions & Answers

Why Calibration is Important

Why Calibration is Important?

Valve Software

Free Control Valve Software Download

Drum water level control

Closed Loop Control System : Boiler Water Level Control System

Belt Conveyor Weighing System

Belt Conveyor Weighing System – Weigh Bridge – Speed Sensor

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?