Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: DP Transmitter Block and Bleed Valves
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Pressure Measurement > DP Transmitter Block and Bleed Valves

DP Transmitter Block and Bleed Valves

Describe how the technician should operate the block and bleed valves to safely remove DP transmitter from service.

Last updated: October 18, 2020 10:38 am
Editorial Staff
Pressure Measurement Practical Questions
No Comments
Share
3 Min Read
SHARE

Suppose a DP transmitter is connected to a process vessel so it may measure a vacuum inside that vessel. Calculate the amount of differential pressure “seen” by this DP transmitter in units of PSID, then calculate its output signal assuming a calibrated range of 0 to 380 inches water column differential and an output range of 4-20 mA:

There is definitely more than one way to calculate the transmitter’s output signal value! Outline more than one of these solutions. Furthermore, suppose an instrument technician decides to remove this transmitter from service in order to disconnect it from the process and then calibrate it back at the instrument shop.

Describe how the technician should operate the block and bleed valves to safely remove it from service, and then describe what the technician should do before operating either the block or the bleed valve to ensure no process upsets occur as a result.

DP Transmitter Block and Bleed Valves

DP Transmitter Block and Bleed Valves

Phigh = 748 mmHgA = 0.9842 Atm = 14.468 PSIA

Plow = 0.15 Atm = 2.205 PSIA

ΔP = 14.468 PSIA − 2.205 PSIA = 12.263 PSID

Shut the block valve first, then open the bleed valve in order to remove the transmitter from service.

Prior to operating either the block or the bleed valve, the technician should first notify operations personnel that the transmitter will be taken out of service and therefore will not register any process vacuum in the near future.

If the transmitter connects to a controller, that controller will need to be placed into manual mode. If the transmitter connects to any pressure alarms or (worse yet!) an emergency shutdown system, those alarms will have to be disabled and/or the shutdown function will have to be bypassed before taking the transmitter out of service.

Incidentally, the atmospheric pressure of 748 torr is equivalent to an altitude of 136 meters above sea level, which makes this a very realistic figure for an industrial application.

More Questions:

  1. What safety hazards might there be for a technician disconnecting and connecting a pressure transmitter to a process vessel such as this?
  2. Demonstrate how to estimate numerical answers for this problem without using a calculator.
  3. What might happen if the vent tube on the “L” side of the transmitter were to become completely plugged?

Share your answers with us through the below comments section.

Read Next:

  • Pressure Transmitter Seals
  • Spool Valve Position
  • Static Pressure Limit
  • Stroke Checking Procedure
  • Pressure Switch Questions

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Practical Process Control System Questions & Answers – 1
Pressure Measurement Objective Questions
Stilling Well in Interface Level Measurement System
Calculate the Thermocouple Output millivolts
Pressure Unit Conversion Practical Example
Calculate Total Hydrostatic Pressure at Bottom of Vessel
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Transmitter Calibration Range of a Vessel Level
Calculate Incident Power in Radar Level Measurement
Motion-Balance and Force-Balance Instruments
Practical Process Control System Questions & Answers – 10
Pressure Transmitter Circuit
Pressure Transmitter Troubleshooting Tips
Pressure Gauge Syphons Principle
Unbonded Strain Gauge Principle

Keep Learning

Instrument Protection Methods: Seals

Connect the Differential Pressure Gauge at the Filter

How Do You Connect the Differential Pressure Gauge at the Filter?

Three-valve Manifold on Remote Seal DP Transmitter

Three-valve Manifold on Remote Seal DP Transmitter

Pressure Switch Questions

Pressure Switch Questions

Alternative Vessel Level Indication

What is the Simple Alternative Vessel Level Indication?

Calculate Hydrostatic Pressure of a vertical column of Acetic Acid

Hydrostatic Pressure of a vertical column of Acetic Acid

simple motor start-stop circuit

Liquid Level Switch Control Logic

Suppose the lamp refuses to light up

Indentify Faults in Simple Lamp Circuit including Failed Wires

Learn More

Cold Email Deliverability

Cold Email Deliverability – Latest Comprehensive Guide

Differential Pressure Sensor with pair of Strain Gauges

Differential Pressure Sensor with Pair of Strain Gauges

Parking Lights PLC Program Explained with Video

Parking Lights PLC Program Explained with Video

Electrical Machines Questions and Answers

Double Excited Magnetic System Quiz

Feedforward control with feedback trim

Feedforward Control Principle

Auto-negotiation in Network

What is Auto-negotiation in Network?

Why are Impulse Lines often Installed in a Sloping Manner (Angle)

Why are Impulse Lines often Installed in a Sloping Manner?

Problem on PLC, HMI, VFD, and Motor Circuit

Problem on PLC, HMI, VFD, and Motor Circuit

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?