Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Bubbler Level Sensor
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Level Measurement > Bubbler Level Sensor

Bubbler Level Sensor

Last updated: December 20, 2019 9:09 am
Editorial Staff
Level Measurement
No Comments
Share
4 Min Read
SHARE

Bubbler Level Sensor has a tube with an opening below the surface of the liquid level. A fixed-rate airflow passes through the tube and out of the opening. Pressure in the tube is proportional to the depth (and density) of the liquid over the outlet of the tube.

Contents
Bubbler Level SensorAdvantages and DisadvantagesRead Next:

Bubbler Level Sensor

Bubbler Level Measurement System

There are no moving parts associated with an air bubbler, which makes them less maintenance-intensive than most other level measurement methods. The only part of the sensor that contacts the liquid is a bubble tube that would be specified at the design stage to be chemically compatible with the material whose level is to be measured.

This method of level measurement is favorable in hazardous areas because there are no electrical components in direct contact with the liquid. The pump or compressor used in providing the stable air supply can be located a distance away in a non-hazardous classified area.

Air bubbler systems are a good choice for open tanks at atmospheric pressure; they can be built so that high-pressure air is routed through a bypass valve to dislodge solids that may clog the bubble tube. The technique is inherently ‘self-cleaning’. It is highly recommended for liquid level measurement applications where ultrasonic, float or microwave techniques have proved undependable.

Bubbler Level Sensor

Figure: Simple diagram to demonstrate an air bubbler level measurement system

Air bubbler systems are used in the fuel storage industry, albeit in small numbers, but are being phased out in favour of the servo gauges and radar systems. This is partly due to the specialist requirements for the maintenance of these air bubbler systems. It is also partly due to the measurement accuracy being in the order of ±10 mm. Therefore, air bubblers are not considered to be as accurate as servo or radar gauges.

Although named ‘air bubblers’ these systems are not limited to just utilizing air. In fact, for gasoline and in-scope substance liquid measurement it is commonplace to use nitrogen instead of air. This is the preferred gas because, amongst other reasons, once it has bubbled through the flammable stored liquid it settles above the surface, providing a nitrogen blanket. This is important if the tank is open-topped because it will help prevent flammable vapor from escaping.

Advantages and Disadvantages

Air bubblers have a number of moving parts that require maintenance. These parts include the valves that isolate the gas supply to the tank for bubbling. In addition to the maintenance of the physical valve, there are a number of electro-mechanical parts of the system which require maintenance, for example, actuators to control the opening and closing of the valves or compressors.

An advantage of the bubbler system, from a maintenance point of view, is that the work required is not at the tank side, therefore reducing the exposure time of the maintenance worker to the gasoline stored in the tanks.

There are a number of known issues with bubbler systems. Operational problems can be encountered if a loss or reduction in bubbler pressure occurs. This may result in either reduced accuracy in level measurement or even total loss in measurement. From a legacy perspective, the availability of replacement parts for this type of system is becoming an issue because systems are going out of production with ‘last time buy’ component stocks depleting.

Read Next:

  • Air Purge Level Sensor
  • Hydrostatic Tank Gauging
  • DP Transmitter Above Tapping Point
  • Boiler Drum Level Transmitter
  • Dip Tape Level Measurement
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Ultrasonic Level Measurement Questions and Answers
Level Troll working principle
Float Level Switch Working Principle Animation
Torque Tube Level Measurement Principle
Which Instrument is at Fault in this System?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Hydrostatic Level Measurement

Hydrostatic Level Measurement

Differential Pressure Level Transmitter Errors

Differential Pressure Level Transmitter Errors

Level Gauge Interface Measurement

Level Gauge Interface & Temperature Problems

Micro-impulse Level Transmitter Principle

Micro-impulse Level Transmitter Principle

Paddle Type Level Switch

What is a Level Switch? Types of Level Switches

Float level gauge Principle

Float Type Level Indicator Principle

Bubbler Level Measurement Animation

Bubbler Level Measurement Animation

magnetic-level-gauge-principle

Magnetic Level Gauge Working Principle Animation

More Articles

Safety Instrumented System SIS Component Selection

SIS Component Selection – Safety Instrumented System

Electrical Machines Questions and Answers

Transformer Construction

smart-transmitters-advanced-diagnostics

Smart Transmitters Advanced Diagnostics

Electrical Machines Objective Questions

Electrical Machines MCQ Series 17

What Happens When a Pump Runs Dry

What Happens When a Pump Runs Dry? How to Avoid it?

Add an alarm display to the graphics.

How to Configure an Alarm in InTouch SCADA?

Flow Measurement Objective Questions

Flow Measurement Objective Questions

resistor-color-coding-example

IEC labelling for Resistors Color Code

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?