Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: How Coriolis Mass Flow Meter Measure Density?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > How Coriolis Mass Flow Meter Measure Density?

How Coriolis Mass Flow Meter Measure Density?

The Coriolis mass flow meter measures the density of the flowing fluid from the frequency of oscillation of the sensor.

Last updated: November 1, 2023 6:28 am
Editorial Staff
Flow Measurement
3 Comments
Share
3 Min Read
SHARE

Coriolis mass flow meter is also capable of giving the density of the flowing fluid, it operates on the same principle as the spring and mass assembly as shown in the diagram below.

Contents
Coriolis Mass Flow MeterFormula

When the suspended mass is pulled down and released, it will move up and down, its motion both driven and limited by the spring, until the vibration is damped. The number of complete oscillations per unit of time is referred to as the frequency of oscillation.

Coriolis Mass Flow Meter

Coriolis mass flow meter Density Measurement

As long as the mass of the object attached to the spring remains the same, whenever the object is pulled and released, the system settles to the same frequency until the movement is damped. This is referred to as the Natural frequency of the system.

If the amount of mass changes, the natural frequency of the system changes;

  1. If the mass is increased, the natural frequency decreases; the weight and spring make fewer oscillations per unit of time.
  2. If the mass is decreased, the natural frequency increases; the weight and spring make more oscillations per unit of time.

The frequency of oscillation is inversely proportional to the square root of the mass.

Formula

The exact relationship is expressed by the formula;

Coriolis flow meter Density formula

where;

f = the frequency

m = mass of the tube

K = constant representing the response of the spring

In the Coriolis mass-flow meter, the oscillating tubes correspond to the spring, and the mass of the tubes plus the mass of their contents corresponds to the mass of the spring assembly.

The drive coil that oscillates the flow tubes is energized periodically through a feedback circuit so that the tubes are always oscillating at their natural frequency.

Density is inversely proportional to the square of the frequency.

The equation is ;

Coriolis flow meter Density

where;

f = the frequency

m = mass of the tube

V = volume of the tube

K = constant representing the response of the spring

Since the volume and mass of the tubes and the spring constant do not change, the density of the fluid can be derived from the frequency of oscillation of the sensor which is mounted on the Coriolis flow tubes.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Flow Measurement MCQ
  • Thermal Dispersion Switch
  • InLine Flow Switch Working
  • What is an Orifice Meter?
  • Flow meters Animation
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Facts About Orifice Flow Meters
Working Principle of Vortex Flow Meter
How does an Orifice Measures Flow?
V Cone Flow Meter – Principle, Advantages, Disadvantages
Orifice Plate Turndown ratio
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
3 Comments
  • Anurag bohre says:
    August 18, 2017 at 2:34 pm

    Hello sir your website instrumentation tool is very good platform to learn for instrumentation engineers I am graduate from electronics and instrumentation branch and now working in control and instrumentation department in thermal power plant sir as you know that there is very much awareness regarding the instrumentation core field scope for the instrumentation branch student, your website is a very good platform to them to learn and to make feel that there are a lot of interesting thing to learn in instrumentation field, sir if I can help you in any manner To make website more useful than please give me chance to help or to assist you thank you very much

    Reply
  • jmw says:
    February 5, 2020 at 11:36 pm

    It is important to note that the early mass meters used the mains frequency to drive the tubes into vibration, typically 50 or 60Hz. It is only when they changed to resonant frequency that density was measurable.

    The treatment here is a very good introduction but in reality there are a number of effects that must be compensated for.
    Temperature: Firstly a correction between the calibration temperature and the operating temperature
    Secondly the temperature effect on stiffness which depends also on materials of construction.
    The pressure effect which also affects tube stiffness, ad high viscosity….. this tends to shift the resonant frequency to lower
    values.
    Velocity of sound effects.
    With Hydrocarbons one may also have to take account of the correction factors in the Manual Of Petroleum Measurement Standards.

    Reply
  • Savan says:
    August 30, 2021 at 8:14 pm

    How density measured in mass flow meter?

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Coriolis Mass Flow Meter Working Animation

Coriolis Meter Explained with Animation

Flow Switch Working Principle Animation

Working Principle of Flow Switch with Animation

Differential Pressure and Pressure Loss

What is Differential Pressure and Pressure Loss?

Spring Loaded Variable Area Flowmeter Working Principle

Spring Loaded Variable Area Flow Meter Working Principle

Square root extractor Parts

What is a Square Root Extractor? – DP Flow Measurement

Flow Switch Working

Flow Switch : What is it? – Applications

What is a Condensate Pot? How to Install it?

multi-variable transmitter

Mass Flow Meters

More Articles

Power Electronics Objective Questions

Single-Phase Half Wave AC-DC Converter MCQ

Less than 40% available Plant Air Compressors made available 100%

Less than 40% available Plant Air Compressors made available 100% for Operations

Summary of Valve Types Characteristics

Summary of Valve Types Characteristics

Power Electronics Objective Questions

Thyristors Objective Questions and Answers

single-acting-vs-double-acting-control-valve-actuators

Single Acting Vs Double Acting Actuators

Instruction List in PLC Programming

What is an Instruction List? – PLC Programming

Analytical Instrumentation Engineering Projects

Top 100 Analytical Instrumentation Engineering Projects

NEMA to IP Ratings

NEMA Enclosure Types Standards

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?