Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Poor Bagging Scale Availability Threatened Production Cuts
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Poor Bagging Scale Availability Threatened Production Cuts

Poor Bagging Scale Availability Threatened Production Cuts

Instrumentation engineering root cause analysis of poor bagging scale low availability threatened production cuts.

Last updated: September 28, 2022 2:51 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Instrumentation engineering root cause analysis of poor bagging scale low availability threatened production cuts.

Contents
Poor Bagging ScaleAuthor Root Cause Solution
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Instruments
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Poor Bagging Scale

Poor bagging scales availabilities: 3 Nos. of scales for filling 50 Kg NPK bags + 1 standby and two for Urea Bagging +1 standby broke down so often that their availabilities were < 30%.

No bulk storage silo forced plant stoppages and enormous production loss.

Author Root Cause Solution

The author found and systematically eliminated root causes are:

  1. Ensured all permanently joined parts are fitted up with adequate interferences and mating parts with sufficient clearances and made them strong and robust
  2. Simplified the electric circuit, by eliminating a device called ‘pulsa pak’ and a relay to make troubleshooting easy
  3. Substituted the flimsy solenoids and limit switches with rugged industrial quality components locally available and housed these in weather and dust tight boxes away from the machines to prevent failed parts from harsh environments and machine vibrations, to reduce failures and to simplify troubleshooting
  4. Replaced the complicated bag grips with homemade simple grips
  5. Thanks to these improvements availabilities and hence overall production exceeded rated capacities
  6. The management was so pleased that they commissioned the author to build 3 machines for the expansion project instead of importing the machines and modifying later. The author built machines cost 35% of imported machines

The above is a very short and oversimplified version. For a complete discussion please consult the Author’s articles on this topic.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Pressure Switch Screwed Cover
  • Too Low-Temperature Readings
  • Pressure Switch Screwed Cover
  • Thermowell Shank to Flange Leaks
  • Magnetic Flow Meter Liner Damaged
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Critical High KiloWatt Motor Winding Burnout Threats
Panel and Field Pneumatic Controller’ Bumpless Transfer Issues
Control Valves – Repeat Actuator Diaphragm Bursts
Problem with Choked Control Valve with Whisper Trim Cage
Automation Panel Electronic Cards Failure investigation
Solving Control Valve Hunting: Instrument Troubleshooting
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

8000 RPM 8000 kW Turbine Problem
Heat Exchanger Tubes Corroded Root Cause Analysis
Poor Electrical Heating Element Lives – Problem Solved
Pressure Switch Frozen Screwed Cover Extends the Plant Shutdown
Finned Tube Steam Leaks – Root Cause Analysis
Root Cause Analysis – Burst Transformers and 11 kV Input Breakers
Too often done riskily repaired Roof Hot Spots eliminated forever
Heat Exchanger Root Cause Analysis (RCA)

Keep Learning

Rotary Granulator Drive

Rotary Granulator Drive Root Cause Analysis (RCA)

Bucket Elevator Wrecks

Many Bucket Elevator Wrecks rob crew morale

4 way solenoid valve root cause

Safety Liquid Ammonia Disconnect threatens NH3 Vapor Spill

Inability to Test Repaired HT Motors

Inability to Test Repaired HT Motors in Workshop Posed Problems

Valve Positioner Torn apart

Pipeline Shakes Torn apart Valve Positioners

Arc Fault Breaker (AFB) Electrical Problem Solved

Premature Arc Fault Breaker Failures

Ball Valve root cause

Ammonia Feed Ball Valve to Ship Tank Closed

Induced Draft Cooling Tower

Cooling Tower fan FRP fan blades saves and saves

Learn More

What is an Altitude Valve

What is an Altitude Valve?

Hazardous Area Questions & Answers

Hazardous Area Classification Questions

Classic Control Circuits

Motor Classic Control Circuits using Single Push button

IR Radio Sensors Objective Questions

IR Radio Sensors Objective Questions

Electrical Machines Objective Questions

Electrical Machines MCQ Series 11

Electrical Heating Objective Questions and Answers

Electrical Heating Objective Questions and Answers

Servo Valve

Proportional Valve and Servo Valves

Electric Circuits Objective Questions

Electric Circuits Objective Questions – Set 6

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?