Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Poor Bagging Scale Availability Threatened Production Cuts
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Poor Bagging Scale Availability Threatened Production Cuts

Poor Bagging Scale Availability Threatened Production Cuts

Instrumentation engineering root cause analysis of poor bagging scale low availability threatened production cuts.

Last updated: September 28, 2022 2:51 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Instrumentation engineering root cause analysis of poor bagging scale low availability threatened production cuts.

Contents
Poor Bagging ScaleAuthor Root Cause Solution
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Instruments
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Poor Bagging Scale

Poor bagging scales availabilities: 3 Nos. of scales for filling 50 Kg NPK bags + 1 standby and two for Urea Bagging +1 standby broke down so often that their availabilities were < 30%.

No bulk storage silo forced plant stoppages and enormous production loss.

Author Root Cause Solution

The author found and systematically eliminated root causes are:

  1. Ensured all permanently joined parts are fitted up with adequate interferences and mating parts with sufficient clearances and made them strong and robust
  2. Simplified the electric circuit, by eliminating a device called ‘pulsa pak’ and a relay to make troubleshooting easy
  3. Substituted the flimsy solenoids and limit switches with rugged industrial quality components locally available and housed these in weather and dust tight boxes away from the machines to prevent failed parts from harsh environments and machine vibrations, to reduce failures and to simplify troubleshooting
  4. Replaced the complicated bag grips with homemade simple grips
  5. Thanks to these improvements availabilities and hence overall production exceeded rated capacities
  6. The management was so pleased that they commissioned the author to build 3 machines for the expansion project instead of importing the machines and modifying later. The author built machines cost 35% of imported machines

The above is a very short and oversimplified version. For a complete discussion please consult the Author’s articles on this topic.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Pressure Switch Screwed Cover
  • Too Low-Temperature Readings
  • Pressure Switch Screwed Cover
  • Thermowell Shank to Flange Leaks
  • Magnetic Flow Meter Liner Damaged
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Pulverizer Electrical Problem Solved
Serious Constraints Prevent using an Available Turbine Flow Meter
11 kV, 3.3 kV, and 400 V systems insulation resistance (IR) Problems
Control Panel Instruments Problem Threatened Plant Shutdown
Repeat Failures of Letdown Valves
Seawater Pipeline Spools from day-1 leaks threaten Plant Shutdown
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Thermocouple Extension Lead Problem
Safety Liquid Ammonia Disconnect threatens NH3 Vapor Spill
Critical High KiloWatt Motor Winding Burnout Threats
Centrifugal Compressor near ½-RPM Frequency High Magnitude Shaft Vibrations
Premature Arc Fault Breaker Failures
Condensate Pump Frequent Wrecks Threatens Long Plant Outages
Bucket elevators Chain and teeth wear Problems
Urea Reactor Top Bolted Plug developed Leaks
Passing Control Valves Cause Yearly Losses in Production Plant
Hunting of Control Valves

Keep Learning

Bently Nevada Proximity Probe

Root Cause Analysis for Vibration Probe Not Responding

Fasteners and General Corrosion of Electrical Motors

Fasteners and General Corrosion of Electrical Motors

Control Valves - Repeat Actuator Diaphragm Bursts

Control Valves – Repeat Actuator Diaphragm Bursts

Inability to Test Repaired HT Motors

Inability to Test Repaired HT Motors in Workshop Posed Problems

Amine Pump Trip - Root Cause Analysis

Amine Pump Trip – Root Cause Analysis

Malfunctioning Inlet Check Valves

Malfunctioning Inlet Check Valves caused chaos at Compressor stop/trip

Control Valve Passing Problem after Overhauling Job

Control Valve Passing Problem after Overhauling Job

Induced Draft Cooling Tower

Cooling Tower fan FRP fan blades saves and saves

Discover More

Boiler Intelligent Control Cabinet

IoT based Smart Boiler Control System with Cloud PLC and SCADA

Things to Know When Measuring Voltage

Things to Know When Measuring Voltage

Rotary UPS or Dynamic UPS

What are Static UPS and Rotary UPS?

ECE Projects - IEEE and IoT Projects List

ECE Projects – IEEE and IoT Projects List

S84 - IEC 61511 Standard for Safety Instrumented Systems

S84 / IEC 61511 Standard for Safety Instrumented Systems

IEC 60909 and IEC 61363 for Short Circuit

Difference Between IEC 60909 and IEC 61363 for Short Circuit

Electrical Motor Failures

Most General Reasons for the Electrical Motor Failures

Tilting Pad Bearing

8000 RPM 8000 kW Turbine Problem

Follow US