Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Gearbox within week Failing Journal Bearing upset Plant Operations
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Gearbox within week Failing Journal Bearing upset Plant Operations

Gearbox within week Failing Journal Bearing upset Plant Operations

Root Cause Analysis (RCA): 1800 kW 8000 to 750 RPM Gearbox (GB) within week failing journal bearing (JBs) upset plant operations.

Last updated: September 28, 2022 3:19 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
6 Min Read
SHARE

Root Cause Analysis (RCA): 1800 kW 8000 to 750 RPM Gearbox (GB) within week failing journal bearing (JBs) upset plant operations.

Contents
Equipment DescriptionGearbox within week Failing Journal Bearing ProblemAuthor RCA studyAuthor temporary RCA SolutionLasting RCA solutionRCA solution implemented benefits
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Miscellaneous Rotating Machine Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Equipment Description

A gearbox (GB) couples an 8000-RPM steam turbine to a 750 RPM 1800 KW plant cooling water (CW) recirculation centrifugal pump.

Another turbine driven pump is standby. 750 RPM motor driven pump is always in parallel with the TDP.

Gearbox within week Failing Journal Bearing Problem

Journal bearings generally last and last. However, the gearboxes’ Journal Bearing (JBs) failing within a fortnight or even sooner, and the crew taking it a way of life surprised the author and prompted him to personally root cause analyze the problem.   

Author RCA study

The author posed RCA queries, the decade long problems handling persons’ answers, history card contents, Gearbox (GB) drawing studies, failed bearing inspection and site visits led to the following conclusions:

  1. The Journal Bearing (JBs) failed first time 1½ year after commissioning.
  2. Crew found the lube pump (LP) shaft end spigot which penetrates a same shaped hole in the high-speed shaft (HSS) broken. Obvious lube-starve ruined the GB all JBs – the first JBs rub failure and need for a local vendor rebabbitting.
  3. The US technician doing no RCA and attributing item to high 8000‑RPM shifted the LP to the 2000 RPM Intermediate speed shaft (ISS) doing the necessary modifications – an unauthorized modification.
  4. Rampant JB failures started then on. The peeled babbitts’ black color indicated high temp failure,
  5. Somehow crews did not consider the blackened babitt and the failures start after the LP shift to ISS. RCA query when the problem started, and little thinking would have identified shifting the LP to ISS as the root cause; it’s elimination would have avoided the subsequent numerous JB failures, because of the following reasons:
  6. The lube pump, a gear pump throughput is proportional to its speed. Hence, now it delivers 2000/8000 = ¼ of the former delivery. Obviously even with the oil pressure controller knob turned all the way in, the lube circulation is far insufficient
  7. The oil circulation not only lubricates the JBs but also takes away the heat gears mesh and JBs generate and rejects it to the CW in the oil cooler to realize normal 65-75o C GB oil temp.
  8. Contact pyrometer shown casing temperature was around 105o C and measured gearbox oil temp 115o C – way too high compared to normal 60‑75o C.
  9. Perhaps the above factors ignorance, the shop made bearing shells and local vendor rebabitting inadequacy mindset made them to accept the situation as a way of life and live with it 8-years long.
  10. Too low oil pressure of 0.4 Kg/Cm2 even at max lube oil pressure controller setting against the common 1.4 bars for similar RPM machines confirmed guessed root cause.

Author temporary RCA Solution

0.8 Kg/Cm2, oil pressure with motor driven aux LP pump in parallel, though better than before is still inadequate.

12oC lower oil temperature confirmed the RC found approach right.

Lasting RCA solution

The GB vendor too agreed with the Author diagnosis and advised 1.8 bars oil pressure, which the GB manual did not show and the experienced rotating machine engineers setting 1.4 bars lube oil pressure for other high-speed machines failed to set in this case.

Since the crew was wary of modifications to shift the LP to HSS, the author rush airfreighted 3 Nos. ISS driven LP – 1 for each GB and 1 as standby.

On fitting the new LPs on ISS, crew had to back up the oil pressure regulator to get 1.8 kg/cm2 oil pressure even stopping the motor driven lube pump. The JB oil temp dropped to normal 65o C

RCA solution implemented benefits

Though the JB failures vanished, and JB temperatures were normal the plant did not realize the expected benefits.

The author checked and found problem 30 described below was the root cause, eliminated it and the plant realized the expected uninterrupted CW pump runs benefits.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Turbo-Compressor Problem
  • Compressor Anti-Surge Control
  • Plant Air Compressors Problems
  • Antifriction bearings (AFB) Problems
  • Acid Dozing Pumps Root Cause Analysis
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Leaky Boiler Drum Level Switch Stops NH3 Plant Commissioning
Minimum Oil Circuit Breaker (MOCB) No Vendor Spares & Service
Ammonia Feed Ball Valve to Ship Tank Closed
Turbo-Compressor Problem – Root Cause Analysis
Doubtful Temperature Readings threatens Soaking Pit Wrecks 
Poorly Built Switchgears – Why Breaker Parts Tear apart or don’t work?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Welding Machine Fail in Dusty and Corrosive Areas
Incident Investigation: Motor Operated Valve Lesson
An Indian Plants all turbines’ low Vacuum & Saudi Plant turbo-compressor only
Less than 40% available Plant Air Compressors made available 100% for Operations
Learnings from the BP Refinery Explosion at Texas City
Cooling Tower Fans Frequently Failing
Cement kilns, Rotary Drum Driers Simplest Electrical Drive
Steam Turbine Driven Centrifugal Compressors Leak due to Broken Instrument

Keep Learning

Inability to Test Repaired HT Motors

Inability to Test Repaired HT Motors in Workshop Posed Problems

Plant Air Storage Tank

Plant Air Storage Tank Pressure Fluctuations Root Cause Analysis

Leaking Plug Valves pose Safety Hazards and Lead to Plant Shutdown

Leaking Plug Valves Pose Safety Hazards and Lead to Plant Shutdown

Damaged Magnetic Flow Meter Flow Tube

None Could Repair Slightly Damaged Magnetic Flow Meter Flow Tube

Flash Vessel All Level Instruments Stopped Working

Ammonia Flash Vessel All Level Instruments Stopped Working

Multistage Flash Drums Erratic Level Readings

Multistage Flash Drums Erratic Level Readings

Process Air Compressor Overhauls Eliminated

Process Air Compressor too Frequent & too Lengthy Overhauls Eliminated

Bently Nevada Proximity Probe

Root Cause Analysis for Vibration Probe Not Responding

Learn More

Gate Valve

How Gate Valves Work ?

Example Program Logic in Allen Bradley PLC

PLC Programming Examples on Industrial Automation

Difference between Analog Signal and Digital Signal

What are Analog and Digital Signals? Differences, Examples

Manometer with two different liquids

Calculate the Height of Glycerine

ISA and SAMA diagrams

What is SAMA Diagram?

Vibration Measurement Questions

Interview Questions on Vibration Measurement

Electrical Machines Questions and Answers

Induction Machines Equivalent Circuit Parameters

Control valve positioner calculation

Calculate Control Valve Stem Position

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?