Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Gap Voltage of Bently Nevada Vibration Probe
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Vibration Measurement > Gap Voltage of Bently Nevada Vibration Probe

Gap Voltage of Bently Nevada Vibration Probe

Last updated: September 7, 2020 12:15 pm
Editorial Staff
Vibration Measurement
4 Comments
Share
2 Min Read
SHARE

Gap voltage (VDC) is a direct representation of distance between the probe’s tip and the shaft’s surface. This is the quiescent voltage that needs to be adjusted between the proximitor’s output voltage range limits.

Any vibration of the shaft will cause the proximitor’s output voltage to vary in precise step.

Vibration Probe Gap Voltage

Bently Vibration Probe Gap Voltage Setting

Gap voltage of Bently Nevada vibration probe is usually set at -10V. Reason for setting at -10 volt is as we know, proximitor allows probe to work from -2 volt to -18 volt.

So voltage difference of 2 to 10 and 10 to 18 is 8 volt. When setting at -10 volt, probe can equally measures vibration at both sides (I mean when shaft is going away from probe or towards probe).

Suppose we adjust probe at -9 volt. Probe can detect vibration?

Yes, it can can detect vibration but its one side will be margin of 7 volt and other side margin of 11 volt.

At 11 volt margin, probe will detect vibration excellent but at other side,7 volt side, it has limitation, when more vibration it may not detect.

(Old system, when proximitor supply was 18 volt, setting were at -8 volt, now such proximitor almost obsoleted)

Share your experience with us on vibration probes using below comments section.

Read Next:

  • Interview Questions on Vibration
  • Calibration of vibration Probe
  • Vibration Switch Principle
  • Bently Nevada Probes Testing
  • What is TK-3 Calibrator ?
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Types of Sensors used in Vibration Measurement
Proximity Transducer System Operation
Root Cause Analysis for Vibration Probe Not Responding
Interview Questions on Vibration Measurement
Bently Nevada 3500 Machinery Protection Systems Hardware Modules
Importance of Vibration Measurement
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
4 Comments
  • Ilias says:
    May 15, 2020 at 9:25 am

    Thanks, you are best, I am technician instrumentation oil and gas the documents please of instrumentation

    Reply
  • Alghefeili says:
    September 1, 2020 at 4:02 pm

    great explanation ,

    Reply
  • scott eric smith says:
    January 19, 2021 at 8:33 pm

    there are time where you may have to set the gap voltage lower. Orbit magazine has some good articles on why you should set it lower. reason for trying to keep it centered is so you don’t cause a not ok signal if the vibration gets to high and causes it to hit the not ok level on the high or low end.

    Reply
  • Mohammed Shakhawan says:
    June 3, 2023 at 12:25 am

    If gap equal – 10 its same vibration value if gap change to – 8 volt?

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What is TK-3 Calibrator ?
AND Logic in Bently Nevada Vibration System
Vibration Monitoring System Step by Step Troubleshooting Guide
Mechanical Vibration Switch Principle
Advantages & Disadvantages of Different Vibration Sensors
Vibration Probe Commissioning Checklist
How to do calibration checks of vibration Probe, extension cable and vibration monitor
Accelerometer Vibration Probe Principle

Keep Learning

Vibration Probe Field Setting Procedure

Vibration Probe Field Setting Procedure

Keyphasor Principle

What is Keyphasor ? How does Keyphasor works ?

Working of Proximitor

Different Types of Turbine Protective Devices

Seismic Transducers Objective Questions

Seismic Transducers Objective Questions

Basics of Vibration Measurement

Basics of Vibration Measurement

Vibration Sensor

Vibration Probes Questions and Answers

Mechanical Vibration Switch

Vibration Switch Working Principle

proximitor module

Bently Nevada Vibration System Verification Procedure

Learn More

Save to Memory Card

How to Save a PLC Project to a Micro Memory Card?

Advanced PLC Programming Training Course

Advanced PLC Course with Programming and Simulation

Chocked flow

Control Valve Cavitation and Flashing

Annunciator Panel

What is a Annunciator Panel?

An Indian Plants all turbines’ low Vacuum

An Indian Plants all turbines’ low Vacuum & Saudi Plant turbo-compressor only

Analog Electronics Objective Questions

Analog Electronics Objective Questions – Set 11

Digital Electronics MCQ

Digital Integrated Circuits Objective Questions – Part 1

pressurized water reactor

SIS Example : Nuclear Reactor Controls

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?