Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Difference between AC and DC Solenoid Valves
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Solenoid Valve > Difference between AC and DC Solenoid Valves

Difference between AC and DC Solenoid Valves

Let's learn the difference between the AC and DC powered solenoid valves used in industrial applications.

Last updated: September 28, 2022 2:38 pm
R Jagan Mohan Rao
Solenoid Valve
3 Comments
Share
4 Min Read
SHARE

The purpose of the solenoid coil is to convert electrical energy into a linear motion.

Contents
PrincipleTypes of SolenoidAC Solenoid versus DC SolenoidOperational NoisePower RequirementsBuzzing NoiseThe Exciting CurrentOperating TimeService LifetimeDesired Attraction Force

Principle

A solenoid valve is an electrically controlled device. The valve consists of a copper wire wound around a hollow form, which is an electric coil with a movable ferromagnetic core also called a plunger located in its center.

In the rest position, the plunger closed off a small orifice. Upon passing a current through the coil, the lines of magnetic flux turn the plunger into an electromagnet.

The generated magnetic field exerts an upwards force on the plunger opening the orifice.

The following image describes the various parts of the solenoid valve.

Solenoid
Image Courtesy: Engineertech.org

Types of Solenoid

Solenoids valves are available with two types of power.

  • AC powered Solenoid
  • DC powered Solenoid

AC Solenoid versus DC Solenoid

Operational Noise

  • If there is a clearance between the movable and stationary iron cores of an AC solenoid, the solenoid coil gets heated up and chances of even coil burn out.
  • In the case of DC solenoid, its exciting current remains constant regardless of the clearance of the movable and stationary iron cores. Therefore, a shock-absorbing material can be provided between the movable and stationary iron cores to minimize operation noises.

Power Requirements

  • AC driven solenoid valves are comparatively larger in size. Consume higher levels of power to produce a relatively slow action.
  • While DC operated solenoid valves use small, solid-state components to produce fast actions from compact devices.
  • AC solenoid valves require a strong peak current to open the valve. Once the valve is open, the current drops to the level which is just sufficient to hold the plunger in place to keep the valve open and running. This helps in reducing the overall power consumption.
  • DC solenoid valves require a constant stable flow of current for their operation resulting in high consumption of electricity as compared to the AC solenoid valves.

Buzzing Noise

  • DC solenoids do not generate the buzzing noise.
  • AC solenoids generate buzzing noise due to the pulsating attraction force. A buzzing noise indicates the plunger is not fully seated. If buzzing is allowed, it will result in overheating of the coil and eventually burn out.

The Exciting Current

  • The exciting current of an AC solenoid is varies depending on the stroke.
  • In the case of DC solenoid, the excitation current is decided by the coil DC resistance only and is constant regardless of the stroke. The heat generated by the resistance to the current flow of the coil winding is constant and weaker regardless of the plunger position.

Operating Time

  • The operating time of the DC solenoid is constant regardless of the frequency. This is because it is driven by DC.
  • The operating time of the AC solenoid not constant and varies with the frequency of operation, which will also affect the heat buildup in the coil.

Service Lifetime

The service life of the DC solenoid depends greatly on the amount of mechanical wear and tear between the movable iron core and the guide (pipe).

The sliding part or section of the guide is specially treated to extend its service life.

Desired Attraction Force

With DC solenoid, the attraction force identical to the actual load can be provided by changing the shapes of the mating section of the movable and stationary iron cores.

Read Next:

  • Solenoid Wiring to PLC
  • Solenoid Valve Manual Reset
  • Do’s and Don’ts in PLC
  • Control Valve Noise Test
  • Solenoid Valve Animation
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Solenoid Valve Troubleshooting Practices
Solenoid Valve Terminology Questions and Answers
How Pilot operated Solenoid Valve Works ?
Solenoid Valve Functional Testing
Solenoid Valves Types & Functions
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
3 Comments
  • Ajay Dumbere says:
    January 3, 2021 at 2:59 pm

    Dear Sir.
    Request to send details of solenoid valve,
    Thank you
    Regards
    Ajay Dumbere

    Reply
  • 13-2-106 , flat no 203 Sai Nagar says:
    May 24, 2021 at 8:57 am

    Sir thanks very much we are get very valuable knowledge
    Thanks

    Reply
  • Trường Giang says:
    September 20, 2021 at 6:52 pm

    thank you very much. i think i get some information that i can use when im working

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

How to Find the Correct Solenoid Valve Size

How to Find the Correct Solenoid Valve Size?

Difference Between Solenoid Valve and Motorized Valve

Difference Between Solenoid Valve and Motorized Valve

solenoid-valves-types-principle-animation

Solenoid Valves Types, Principle & Animation

Online Testing of Solenoid Valve

Design and Accessories Required for Online Testing of Solenoid Valve

Solenoid-Valve-Working-Animation

Solenoid Valve Working Animation

4 way Solenoid Valve Principle

What is a 4-way Solenoid Valve?

Electric Solenoid Actuators Principle

What is a Electric Solenoid Actuator ?

Solenoid-Valve-Manual-Reset-function

Solenoid Valve with Manual Reset Working Principle

More Articles

PLC Raw Count Calculation formula for Pressure Transmitter

PLC Raw Count Calculation for Pressure Transmitter

level control system

Practical Process Control System Questions & Answers – 10

Beam-Detectors-Working-Principle-2

Beam Detectors Working Principle Animation

Siemens TIA Portal Free Version Download

Siemens TIA Portal Free Version Download

Piston Type Flow Meter Principle

Types of Variable Area Flow Meters

Interface Level Measurement Selection Guide

Interface Level Measurement Selection Guide

Reading Clock data in PLC

Real-Time Clock in Omron PLC? – CX Programmer

Carbon Monoxide Gas Hazards

Carbon Monoxide Gas Hazards

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?