Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Re-calibrate the Foxboro DP Pneumatic Transmitter
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Practical Questions > Re-calibrate the Foxboro DP Pneumatic Transmitter

Re-calibrate the Foxboro DP Pneumatic Transmitter

Re-calibrate the Foxboro model 13 DP pneumatic transmitter to a new range of 0 to 180 inches water column.

Last updated: October 1, 2020 4:49 pm
Editorial Staff
Practical Questions
No Comments
Share
2 Min Read
SHARE

Suppose this Foxboro model 13 pneumatic based DP transmitter has a calibrated range of 0 to 125 inches water column and an instrument air supply pressure of 20 PSI:

Contents
Foxboro TransmitterRead Next:

Foxboro Transmitter

Foxboro model 13 DP transmitter

Identify which way the range wheel would have to be moved in order to re-calibrate the transmitter to a new range of 0 to 180 inches water column (from 0 to 125 ”W.C.), explaining your reasoning.

Identify which way the zero screw would have to be turned in order to re-calibrate the transmitter to a new range of 15 to 140 inches water column (from 0 to 125 ”W.C.), explaining your reasoning.

Answer:

Move the range wheel up in order to re-calibrate from 0-125 ”W.C. to 0-180 ”W.C.

Turn the zero screw for less tension against the range bar (less force pulling the bottom of the range bar to the right) in order to re-calibrate from 0-125 ”W.C. to 15-140 ”W.C.

More Questions:

1. Explain why it is important we know whether this mechanism is motion- or force-balance to be able to correctly determine the effects these changes will have on calibration.

2. What would happen if the capsule were to develop a leak?

3. What would happen if the flexure connecting the tops of the force and range bars were to break in half, leaving those two bars disconnected from each other?

4. What would happen if the air supply pressure were to increase from 20 PSI to 22 PSI?

5. What would happen if the air supply pressure were to decrease from 20 PSI to 18 PSI?

Share your answers with us through the below comments section.

Read Next:

  • Fire and Safety
  • Thermocouple Details
  • Flapper Nozzle Questions
  • Flow Meter Calculations
  • Automobile Electrical System

Credits: Tony R. Kuphaldt

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Determine the Pressure at Each Port of DP Transmitter
Which Instrument is Faulty? Transmitter, Recorder, or Controller
Calculate the Height of Glycerine
Air Compressor Control Circuit Problem
Calculate the Transmitter Values
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Drum Level differential pressure transmitter

Calculate Differential Pressure Sensed by Level Transmitter

Steam Eductor Question

Steam Eductor Question

steadily pour a liquid into vertical tube

Vertical Tube Liquid Level Equilibrium

Pneumatic Relay

Pneumatic Relay Questions

Dry Leg

Calculate 0%, 50%, and 100% Calibration Points for ΔP transmitter

Inclined Water Manometer

How much Pressure is applied to Inclined Water Manometer?

burner management system P&ID

Solenoid Valves Questions & Answers – 1

DP Transmitter Problem

DP Transmitter Problem

More Articles

Bonding and Grounding Electrical Systems

Testing and Inspection of Bonding and Grounding Systems

Stepper Motors Objective Questions & Answers

Stepper Motors Objective Questions & Answers

half-wave-voltage-doubler-using-diodes

Half Wave Voltage Doubler using Diodes

Float & Dial Level Gauge Principle

Float & Dial Level Gauge Principle

Draw the Symbols for Liquid Level Measuring Instruments

Draw the Symbols for Liquid Level Measuring Instruments

Top 100 Control Systems Objective Questions & Answers

Top 100 Control Systems Objective Questions & Answers

Stability in Frequency Domain

Mathematical Preliminaries

PLC Program for Fish Feeding System

PLC Program for Fish Feeding System

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?