Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: What is Blowdown Valve (BDV)?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Valves > What is Blowdown Valve (BDV)?

What is Blowdown Valve (BDV)?

The primary function of a Blowdown valve is to control the concentrations of suspended & total dissolved solids (TDS) in the boiler.

Last updated: November 13, 2020 6:22 pm
Editorial Staff
Control Valves
2 Comments
Share
3 Min Read
SHARE

The blowdown valves are used for operation in the open position. The main function of the blowdown valve is mainly to control a continuous flow of steam/fluid under high differential pressure.

Contents
Blowdown Valve (BDV)Applications of Blowdown valvesTypes of Blowdown valvesContinuous Blowdown (CBD) valvesIntermittent Blowdown (IBD) valves

The outstanding feature of this type of valve is that it can maintain fluid-tightness and it is easily operated without the help of any wedging action.

Blowdown Valve (BDV)

What is Blowdown Valve (BDV)

Applications of Blowdown valves

The primary function of a blowdown valve is to control the concentrations of suspended & total dissolved solids (TDS) in the boiler.

Boiler blowdown is a severe service application which results in rapid erosion and wearing out of conventional valves.

Types of Blowdown valves

Continuous blowdown is usually an on-going process, whereas intermittent blowdown is performed on an as needed basis.

Continuous Blowdown (CBD) valves

Continuous Blowdown (CBD) valves are designed to operate in continuous open position by releasing water continuously through a blowdown tap near the boiler water surface, thereby maintaining the TDS level in the boiler drum.

Continuous Blowdown Valve is an angle type valve with a needle shaped trim in a venturi diffuser. The venturi diffuser provides sufficient area for the high velocity flashing water, thereby avoiding choked flow.

Intermittent Blowdown (IBD) valves

Intermittent Blowdown (IBD) valves are designed to operate at predetermined intervals by releasing water & accumulated sludge periodically through a blowdown tap near the bottom of the boiler.

The primary requirement of these valves is to provide tight shut-off even after repetitive blowdown operations.

Earlier, these two functions (blowdown and sealing) were performed by two different valves installed in series and operated in a definite sequence.

Intermittent Blowdown Valve carries out both these functions in sequence i.e. blowdown in open position and sealing in closed position.

This is achieved by providing a multi-step throttling plug, which splits the total pressure drop across each step.

The sealing area is separate from the throttling area, which reduces erosion and provides leak tightness even after prolonged usage.

Read Next:

  • Control Valve flow coefficient
  • Interview Questions on Valves
  • Control Valve Animation
  • Valve Flow Characteristics
  • Control Valve Connections
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

What is Travel Stop in Control Valve?
Butterfly Valves Construction, Types, Stem & Bonnet Assembly
Classification of Gate Valves
Exclusive Control Valve Sequence
Free Control Valves Course
Difference between BDV and PSV
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
2 Comments
  • S M Shoaib says:
    February 10, 2020 at 3:16 pm

    Very important information is available here.

    Reply
  • Arghama De says:
    July 1, 2020 at 12:23 pm

    Very informative article. I have a doubt, please clarify.

    Is it a good engineering practice to take close feedback of battery limit shutdown valves before open command goes to BDV during depressurization?
    Please share the reason.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Working of Rupture Disk
Rotary Stem Valves
Valve Basics, Sizing, and Actuators Books
Deluge Valve Operation
Control Valve Stroke Test Procedure
Face to Face Dimension of Control Valve
When to choose Full Bore Valve or Reduced Bore Valve ?
Fluid Power Systems

Keep Learning

Motor Operated Valve Problems and Troubleshooting

Motor Operated Valve Problems and Troubleshooting

Cage-guided globe valves

What is Cage-guided Globe Valve ?

Refrigeration Compressor Turbine Not-tripping when needed Trip

Refrigeration Compressor Turbine Not-tripping when needed Trip

solenoid-valves-types-principle-animation

Solenoid Valves Types, Principle & Animation

On-OFF Valve Animation

What is ON/OFF Valve ?

Control Valve End Connection

Control Valve End Connection

Needle Valve Schematic

How Needle Valve Works ?

Pressure Relief Valve Terminology

Pressure Relief Valve Terminology

Learn More

Analyzers Questions and Answers

Paramagnetic Oxygen Analyzers Questions & Answers

Create Ladder Diagram from Boolean Logic

Create Ladder Diagram from Boolean Logic

Bipolar Junction Transistor Construction

Bipolar Junction Transistor Construction

Temperature-gauge-calibration

Temperature Sensor calibration procedure

OB and FB Blocks in Siemens PLC

Procedure for Siemens S7-300 Download from PC to PLC

simple latching motor control circuit

Motor Control Circuit Wiring

noise-abatement trim

Control Valve Noise Problems

PID Controllers with output high select Logic

PID Controllers with Output High Select Logic

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?