Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Tilt Level Switch Working Principle
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > How It Works > Tilt Level Switch Working Principle

Tilt Level Switch Working Principle

Last updated: March 17, 2018 4:29 pm
Editorial Staff
How It Works Level Measurement Switches
1 Comment
Share
4 Min Read
SHARE

Tilt SwitchesTilt Level Switch Operation

Monitor’s line of tilt bin level switches are economical, trouble-free point level controls available for detection of dry bulk materials. The units can be used as high level indicators to eliminate bin overflow or to control levels in open piles. In addition, the tilt switches are useful in determining over or under-load on conveyor belts. The simple yet efficient internal construction (one moving part) provides indication when unit is tilted at a 17° angle throughout the complete 360° of axial arc. Each tilt switch includes a threaded bore for attaching extension actuators which can increase sensing repeatability and protect the tilt switch from direct contact with coarse material. Monitor offers two different models of tilt switches, each suited to satisfy different application requirements.

Summary:

Tilt level switches are used for high level indication as they are installed suspended on a cable or chain above the material being sensed.  As the material height increases and comes in contact with the probe the material pushes the probe to the side and tilts it.  When the probe is tilted at approximately 25 degrees a ball on the inside rolls off the contact and actuates the switch.  When the material level decreases the probe falls back to being vertical and the switch reverts to its normal state.

Principle of OperationTilt Switch Working

A tilt switch provides level indication by detecting the angular position of the tilt switch enclosure. Typically the unit is suspended above the material to be sensed. Internally, a steel ball centers itself over a switch resulting in switch actuation. As rising material contacts the tilt switch (or the extension actuator) the enclosure begins to tilt. When the enclosure body is tilted at 17° (or any other angle specified by vendor), the steel ball rolls off center, deactivating the switch. As material falls away from the switch enclosure body (or the extension actuator) and the unit becomes upright, the ball returns to its original centered position, once again causing switch actuation. The change in the internal switch status is user accessible for signaling alarms, lights, or interfacing with a PLC.

Advantages: This technology is very advantageous for open storage applications where it would not be possible to mount a fixed sensor.  They are also very good for large particulate materials.

  • High level detection of grains, granules, pellets, or ingredients in bins, tanks and silos
  • Mounts on the top of the bin as an alternative to an extended rotary or can be mounted over a conveyor belt
  • Works in powders and solid materials

Disadvantage: They are mechanical and will wear, will only work for heavy products, and are mounting specific.

Applications:Tilt Switch image

• High Silo Level
• Crusher Bowl Level
• Empty Conveyor Alarm
• Classifier Screen overload
• Conveyor Belt Overload
• Hopper Railcar Loading Tool 
• Conveyor Belt Misalignment
• Vibratory Feeder Starvation
• Plugged Chute Alarm
• Differential Level Control

Also See: Tilt Switch Working Principle Animation

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
What is a Bridle?
Switch Types and Common Terminology
Level Instruments General Specifications
Which Instrument is at Fault in this System?
Hydrostatic Level Measurement
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • ramesh says:
    October 17, 2016 at 6:44 pm

    sir please detail for displacer magnetic switch. how its working with animation.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

How a Level Switch Works

Elevated Span and Suppressed Span

DP Level Transmitter Elevation and Suppression Corrections

Radiation Level Measurement Principle

Radiation Level Measurement

Paddle Wheel Level Switch Principle

Paddle Wheel Level Switch Principle

Temperature Switch Calibration

How to Calibrate Temperature Switch? – Instrument Basics

Level Gauges Questions and Answers

Level Gauges Objective Questions and Answers – Instrumentation

DP Transmitters Level Measurement Principle

DP Transmitters Level Measurement Principle Video

Asymmetric capillary for Level Measurement

Effects of Symmetric and Asymmetric Capillary Tube Pressure Measurement

More Articles

Power Electronics Objective Questions

Power Transistor Objective Questions

Basics of Explosion Protection

Basics of Explosion Protection

What is a Thermopile ?

2-way solenoid valve Normally Closed

What is a 2-way Solenoid Valve ?

process conditions, Find out the Circuit Components Status

As per Process Conditions, Find out the Circuit Components Status ?

Ion Spectrometers Questions & Answers

Instrumentation for Electron Spectroscopy

Open Loop and Closed Loop System Questions

Open Loop and Closed Loop System Questions Answers

How to Test a Pressure Switch ?

How to Test a Pressure Switch ?