Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Convert Linear mA to Square root mA
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Instrumentation Tools > Convert Linear mA to Square root mA

Convert Linear mA to Square root mA

Last updated: November 12, 2019 4:10 pm
Editorial Staff
Instrumentation Tools
2 Comments
Share
0 Min Read
SHARE

Convert Linear mA to Square root mA:

This tool is used to convert the transmitter Linear mA signal into the equivalent square root mA signal.

This calculation tool is used to Convert Linear mA to Square root mA

 

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Boiler Drum Level Transmitter Calibration
Convert Process Variable to Percentage
0-20 mA Analog Signal to Measurement Converter Tool
Differential Pressure (DP) Level transmitter Installed Below Tapping Point
Transmitter Current Conversion Tool
Density Measurement using DP Transmitter for closed tank with wet leg
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
2 Comments
  • Abdullah Khan says:
    August 30, 2016 at 10:22 am

    this calculation not working can you please correct it sir

    Reply
    • S Bharadwaj Reddy says:
      August 30, 2016 at 12:16 pm

      Hello, Please enter 4 mA or above value. Click once outside after entering the value. Thank You.

      Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Density Measurement for Open Tank with Constant Level Application
Convert Linear Percentage to Square root Percentage
Conversion of Transmitter Output in Percentage to Process Variable
Measurement Value to 4-20mA Signal Converter
Level Measurement with Wet leg and Installed Below Tapping Point
Convert Percentage (0-100%) to current (4-20mA)
Differential Pressure (DP) Level transmitter Installed Above Tapping Point
Instrumentation Calculator

Keep Learning

4-20 mA to Measurement Converter

4-20 mA to Measurement Converter Tool

Current to percentage conversion

Convert current (4-20mA) to Percentage (0-100%)

DP-Flow-Transmitter-Re-Ranging-calculation

DP Flow Transmitter Re-Ranging Calculation

Interface level Measurement

Interface Level Measurement using DP Transmitter

DP-Level-Transmitter-Diaphragm-with-capillary-tube-type

DP Level Transmitter Calibration for Diaphragm Seal with Capillary

Closed-Tank-DP-Type-Level-Measurement-with-Dry-leg-and-transmitter-installed-below-tapping-point

Level Measurement with Dry leg and Installed Below Tapping Point

Calculate-current-4-20ma-from-process-varibale-pv

Calculate Current (4-20ma) from Process variable PV

Calculate Resistance from Temperature for RTD

RTD Calculator : Calculate Resistance from Temperature

Learn More

Importance of Fire & Gas Detection System

Importance of Fire & Gas Detection System

Combining Independent Current Sources in Parallel

Combining Independent Current Sources in Parallel

What is Directional Control Valve (DCV)?

What is Directional Control Valve (DCV)?

Pneumatic Systems Objective Questions

Pneumatic Systems Objective Questions

Field Instruments

Is Vacuum affects Field Instruments in Industries?

Comparison of Venturi and Orifice flow meterComparison of Venturi and Orifice flow meter

Comparison of Venturi and Orifice flow meter

Liquefied Petroleum Gas (LPG)

Properties of Liquefied Petroleum Gas (LPG)

Interview Questions & Answers on Alternators

Interview Questions & Answers on Alternators

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?