Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Condensate Pump Frequent Wrecks Threatens Long Plant Outages
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Condensate Pump Frequent Wrecks Threatens Long Plant Outages

Condensate Pump Frequent Wrecks Threatens Long Plant Outages

Root Cause Analysis (RCA) related to the Condensate Pump Frequent Wrecks Threatens Long Plant Outages.

Last updated: September 28, 2022 3:19 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Root Cause Analysis (RCA) related to the Condensate Pump Frequent Wrecks Threatens Long Plant Outages.

Contents
ProblemAuthor Solution
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Miscellaneous Rotating Machine Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Problem

Several large steam turbines condensers condensate collects into two buried tanks. The tanks to 20% is above ground (below figure).

Tank 1 has top mounted turbine driven submerged pump and tank 2 motor driven same standby pump.

During many pump changeovers many pumps’ carbon bushes supporting the long shaft coupling to the drive failed. At nearly all spares used up condition the belabored engineer sought the author’s SOS help.

Surface Condenser Condensate Evacuation Pumps

Author Solution

The root cause analyzing witnessed a pump changeover: Operators opened the 3” waterside valve (above figure) to fill the condensate collection tank. They were about to push the motor start PB.

 Hold, shouted the author and asked, “Have you opened the steam side valve?” The perplexed operator grinned and said, “Steam side valve, Sir, no supervisor told me to open it”.

The author called the operations engineer and he too was ignorant of the steam side valve. The author explained, “the condenser is under high vacuum. Hence, unless the pit tank top is open to the same vacuum water cannot flow into the tank.

Hence, you must open both the ¾” steam side and the 3” water valves and wait for 5 minutes to be sure of enough condensate collection to submerge the pump. So far you have been wrecking pumps because of dry running!”              

The sheepish operator opened the steam side valve also, waited 5-minutes and then changed over to the motor driven pump safely. Thus, the author prevented another wreck and all future wrecks!

By a memo, the author requested the operations manager to revise the pump start up procedure and to hold classes for all operators, and shift engineers in Arabic.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Turbo-Compressor Problem
  • Compressor Anti-Surge Control
  • Plant Air Compressors Problems
  • Plant Turbo-compressor Problem
  • Failing Plant Air Compressor Drives
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Supplied Screen Vibrators Perennial Problems
Turbine Flow Meter (TFM) Field Calibration Uncommon Request
Compressor Anti-Surge Control near-miss incident
Fired Boiler Induced Draft Fan (IDF) Failures Upset all Plants Operations
Minimum Oil Circuit Breaker (MOCB) No Vendor Spares & Service
HT Motor Direction of Rotation (DOR) Changed
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Poorly Engineered, built & often Failing Plant Air Compressor Drives
Pipeline Shakes Torn apart Valve Positioners
Rotary Granulator Drive Root Cause Analysis (RCA)
Control Valves – Repeat Actuator Diaphragm Bursts
Thermowell Shank to Flange Repeat Weld Leaks
Seal Pressure Instruments Root Cause Analysis
Centrifugal Compressor near ½-RPM Frequency High Magnitude Shaft Vibrations
Pressure Correction Pneumatic Instrumentation

Keep Learning

Instrumentation Engineering Root Cause Analysis

Instrumentation Engineering Problems Solved – Root Cause Analysis

Leaking Plug Valves pose Safety Hazards and Lead to Plant Shutdown

Leaking Plug Valves Pose Safety Hazards and Lead to Plant Shutdown

Plant Shutdown Analysis: Valve Closed and SOV Coil Failure

Plant Shutdown Analysis: Valve Closed and SOV Coil Failure

Testing of Pneumatic Systems

Panel and Field Pneumatic Controller’ Bumpless Transfer Issues

Captive Power Plant Trip Root Cause Analysis

Captive Power Plant Trip Root Cause Analysis

Erratic Stroking Control Valves

Erratic Stroking Control Valves Delaying the Shutdown Plant Restart

Rolled & Seal Welded Tube to Tube sheet joints

Gas Cooler Re-tubing Done Successfully (Root Cause Analysis)

Single Bearing Motor Stator Winding

Critical High KiloWatt Motor Winding Burnout Threats

Learn More

Strain Gauge Pressure Transducer

Resistance Type Pressure Transducers Principle

Flame Ionization Detector (FID)

Flame Ionization Detector (FID) Principle

Power Supply Voltage Regulator Problem

Troubleshooting a Power Supply Circuit

Diagnosing the Electric Motor Circuit

Diagnosing Electric Motor Circuit

Allen-Bradley SLC 500

History of Programmable Logic Controllers (PLC)

Computer Science and Technology Certifications

Computer Science and Technology Majors Certifications

Pressure Gauge Parts

Pressure Gauges with Bourdon Tube Principle

Difference Between Resistive Touch and Capacitive Touch

Difference Between Resistive Touch and Capacitive Touch

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?