Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Condensate Pump Frequent Wrecks Threatens Long Plant Outages
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Condensate Pump Frequent Wrecks Threatens Long Plant Outages

Condensate Pump Frequent Wrecks Threatens Long Plant Outages

Root Cause Analysis (RCA) related to the Condensate Pump Frequent Wrecks Threatens Long Plant Outages.

Last updated: September 28, 2022 3:19 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
3 Min Read
SHARE

Root Cause Analysis (RCA) related to the Condensate Pump Frequent Wrecks Threatens Long Plant Outages.

Contents
ProblemAuthor Solution
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Miscellaneous Rotating Machine Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Problem

Several large steam turbines condensers condensate collects into two buried tanks. The tanks to 20% is above ground (below figure).

Tank 1 has top mounted turbine driven submerged pump and tank 2 motor driven same standby pump.

During many pump changeovers many pumps’ carbon bushes supporting the long shaft coupling to the drive failed. At nearly all spares used up condition the belabored engineer sought the author’s SOS help.

Surface Condenser Condensate Evacuation Pumps

Author Solution

The root cause analyzing witnessed a pump changeover: Operators opened the 3” waterside valve (above figure) to fill the condensate collection tank. They were about to push the motor start PB.

 Hold, shouted the author and asked, “Have you opened the steam side valve?” The perplexed operator grinned and said, “Steam side valve, Sir, no supervisor told me to open it”.

The author called the operations engineer and he too was ignorant of the steam side valve. The author explained, “the condenser is under high vacuum. Hence, unless the pit tank top is open to the same vacuum water cannot flow into the tank.

Hence, you must open both the ¾” steam side and the 3” water valves and wait for 5 minutes to be sure of enough condensate collection to submerge the pump. So far you have been wrecking pumps because of dry running!”              

The sheepish operator opened the steam side valve also, waited 5-minutes and then changed over to the motor driven pump safely. Thus, the author prevented another wreck and all future wrecks!

By a memo, the author requested the operations manager to revise the pump start up procedure and to hold classes for all operators, and shift engineers in Arabic.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Turbo-Compressor Problem
  • Compressor Anti-Surge Control
  • Plant Air Compressors Problems
  • Plant Turbo-compressor Problem
  • Failing Plant Air Compressor Drives
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

18 Temperature Sensors Fault Leads to Plant Shutdown
11 kV, 3.3 kV, and 400 V systems insulation resistance (IR) Problems
Boiler Feed Water Heater Shell Flange Leaks
Poor Bagging Scale Availability Threatened Production Cuts
Many Bucket Elevator Wrecks rob crew morale
Transformers Coolers Weld Joints Oil Oozes Were Eye Sores
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Flange Joint Errors shutdowns root cause analyzed and eliminated
Instrumentation Engineering Problems Solved – Root Cause Analysis
Repeat Control Valve Plug Stem and Gland Leaks
Captive Power Plant Trip Root Cause Analysis
Erratic Radar Level Gauges Delays a Refinery Commissioning
Root Cause Analysis for Vibration Probe Not Responding
Urea Reactor Top Bolted Plug developed Leaks
Repeat Failures of Letdown Valves
Erratic Stroking Control Valves Delaying the Shutdown Plant Restart
Frequent Feeder-A Lightning Arrester (LA) Bursts – Root Cause Analysis

Keep Learning

Thermocouple Extension Lead Minimizer Circuit

Thermocouple Wires and Extension Lead Issues

Heat Exchanger Baffles Holes

Heat Exchanger Tubes Corroded Root Cause Analysis

Centrifugal Compressor Shaft Vibrations Problem

Centrifugal Compressor near ½-RPM Frequency High Magnitude Shaft Vibrations

Target Flow Transmitter Problem

Unreliable Ammonia Flow Transmitter Reading and Problems

Rotary Drier Shell to Split Gear drive

Rotary Drier Shell to Split Gear drive eliminates too frequent drive failures

Steam Turbine Driven Centrifugal Compressors Leak due to Broken Instrument

Discharge Head 3‑monthly leaks of Steam Turbine Driven Centrifugal Compressors

Welding Machine Fail in Dusty and Corrosive Areas

Welding Machine Fail in Dusty and Corrosive Areas

Control Valves - Repeat Actuator Diaphragm Bursts

Control Valves – Repeat Actuator Diaphragm Bursts

Discover More

Difference between MCB and RCBO

Difference Between MCB and RCBO

Helix and Spiral Tubes - Pressure Sensor

Helix and Spiral Tubes – Pressure Sensor

PLC Program for Burglar Alarm Security System

PLC Program for Alarm Security System

Applications of Digital Control Valves

Digital Control Valves – Introduction, Principle, Setup, Applications

Analyzers Questions and Answers

Magnetic Wind Instruments Questions & Answers

DPDT switch

Switch Types and Common Terminology

Inductive proximity switches

How to Connect Proximity Switch (Source Type) to Make LED ON ?

Liquid Tank Filling and Emptying PLC System

Auto and Manual Liquid Tank System: PLC Program Example

Follow US