Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: The Replacement Procedure for Control Valve Stem Packing
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Valves > The Replacement Procedure for Control Valve Stem Packing

The Replacement Procedure for Control Valve Stem Packing

Stem packing is a type of seal, damps leakage between moving part and housing, is essential for the control valve.

Last updated: September 28, 2022 2:34 pm
R Jagan Mohan Rao
Control Valves
1 Comment
Share
5 Min Read
SHARE

Stem packing is a type of seal, damps leakage between moving part and housing, is essential for the control valve.

Contents
Control Valve Stem PackingReplacement Procedure for Valve Stem PackingDos and Don’ts  How to Remove Stem Packing?

Control Valve Stem Packing

How to Remove Control Valve Stem Packing Procedure

There are few main criteria for the selection of valve packing.

They are

  • Chemical resistance,
  • Stem movement (speed),
  • Pressure in the flow system,
  • Medium temperature.

Replacement Procedure for Valve Stem Packing

The stem packing should be replaced preferably every 2 to 3 years even though valves have no failure such as leakage.

It is required to reduce valve operating torque and to prevent stem wear.

Procedure for Valve Stem Packing

First of all, the correct selection of packing materials is confirmed, so that stem packing is suitable for the maximum working pressure and temperature of the process and the kind of fluid being handled.

Selection of a proper tool to take out the packing so as not to damage like scratches on the valve stem and valve packing chamber or stuffing box.

Clean the valve stem and valve packing chamber properly and carefully from the formation of scratches.

In general, the packing should be as thick as half the difference between the valve stem diameter and the interior diameter of the packing chamber or stuffing box. If no such packing is available, slightly thicker packing will do, but thinner packing is not suggested under any circumstances.

Preferably, with a sharp cutting device or packing cutter, cut the selected packing with a 30 degree to 40-degree at an inclined angle. The length of each piece of packing must be sized properly so that both ends may meet one another with the proper, correct dimension.

Dos and Don’ts  

Inspection of the stuffing box and the stem is important because both should be clean from burrs, pitting, scoring, or corrosion on its surface.

Loading all pieces of packing at a time is not advised. Load the packing to half the death of the packing chamber, and press them down once. Then load the remaining pieces of packing and tighten them securely.

All gland packing should be located so that the seams are 120 degrees apart from each other. This will place the seam of the fourth packing ring position in the same vertical orientation as the first one.

Gland packing should not be tightened totally once for all, it is usually tightened to a position 3 to 4mm (1/8’’) below the top end of the packing chamber. If any leakage is found, tighten the packing further down till leakage stops.

How to Remove Stem Packing?

It is very hard in taking out or removing a gland packing can be very difficult sometimes, particularly if it is old and well set, it is necessary to have specially contoured tools.

There are also gland packing extractors available in the market, which are flexible and can be pulled out old packing smoothly.

How to Remove Valve Stem Packing

They just have to be twisted with the special tool to get a grip and then the packing can be pulled out. The problem comes when the old packing has lost its properties and the packing comes out in fibers.

Insert a stiff wire to measure the length of the valve bonnet. Measure the inner diameter of the bonnet and the outer diameter of the stem.

Suggest these two measurements and divide them by two. This is the packing thickness. Divide the depth of the packing chamber by the packing thickness to get the number of packing rings required.

Reference: The Valve Primer by Brent T Stojkov.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Valve Interlock
  • Cavitation Test Setup
  • Basics of Valve Actuators
  • Types of Control Valve Actuators
  • The Relation between Kv and Cv
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Importance of Proper Control Valve Sizing
Solenoid Valve Troubleshooting Practices
What is a Float Control Valve? Types, Advantages, Disadvantages
What is Plug Valve ?
How Pilot operated Solenoid Valve Works ?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
1 Comment
  • anand says:
    August 15, 2021 at 2:58 am

    very good information sir thank you

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Solenoid Valve Troubleshooting

Solenoid Valve Troubleshooting Tips

How to Do Maintenance of Control Valve Which is Stuck in Field?

How to Do Maintenance of Control Valve Which is Stuck in Field?

cut-away control valve

How Globe Valves Work ?

What is Instrument Air Manifold

What is Instrument Air Manifold ?

Choked Flow of Control Valve

Choked Flow of Control Valves

Control Valves Leakage Classifications

Control Valves Leakage Classifications

Solenoid Valve Functional Testing

Solenoid Valve Functional Testing

Valve Software

Free Control Valve Software Download

More Articles

4-20ma-formulas-and-examples

4-20mA Formulas and Examples

Turbine Bypass System

Turbine Bypass System

State Variable Analysis and Design

State Variables & Linear Discrete Time Systems

Automatic exhaust fan control

XG5000 PLC Programming for Automatic Exhaust Fan

relationship between resistance, reactance, and impedance

Impedance

Gas Detectors Location Installation

Gas Detectors Installation Techniques

Difference between Signal Cables and Control Cables

Difference between Signal Cables and Control Cables

Signal Isolator

What is a Signal Isolator? Principle, Advantages, Disadvantages

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?