Reading: How to Connect PLC with SCADA System via OPC UA?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > How to Connect PLC with SCADA System via OPC UA?

How to Connect PLC with SCADA System via OPC UA?

In this article, we are configuring a connection between Siemens PLC S7-1500 and Indusoft SCADA System via OPC-UA.

Last updated: September 28, 2022 2:23 pm
Hussien Ghareb
PLC Tutorials
No Comments
Share
5 Min Read
SHARE

In this article, we are configuring a connection between Siemens PLC S7-1500 and Indusoft SCADA System via OPC-UA.

Contents
IntroductionWhat makes the OPC Protocol Special?The key features of OPC UASteps to set the connection between PLC and SCADA

Introduction

One of the most important protocols all over the Automation Industry is OPC protocol that is developed by OPC Foundation.

Here we are going to know how to establish an interface between a SIEMENS PLC and a SCADA system (Indusoft Web Studio V7.1) using the OPC-UA infrastructure.

What makes the OPC Protocol Special?

The communication protocols are many and each vendor in the Automation field has made a special protocol for himself, as an example, we can see that SIEMENS products are using the PROFIBUS & PROFINET protocols to communicate with each other.

But on the other hand, we can find that Allen Bradley PLCs are using Ethernet/IP protocol to communicate with each other, and that is the situation for all vendors.

That is why we have invented the OPC (Open Platform Communication) protocol that can create data transfer standards for multi-vendor, multi-platform, secure, and reliable interoperability in industrial automation.

The key features of OPC UA

  • OPC UA does not depend on a specific operating system platform. OPC UA can, for example, be used with Windows, Linux, Mac OS X, a real-time operating system or a mobile operating system (such as Android).
  • OPC UA is implemented in various different programming languages.
  • Independence of a specific transport layer.
  • The information from the OPC UA server (for example the PLC tags) is modeled as nodes connected over references. This makes it possible to navigate from node to node with an OPC UA client and find out what content can be read, monitored or written.

Steps to set the connection between PLC and SCADA

First of all, we need to launch the OPC UA server from the S7-1500 PLC.

Step 1:

Open new project with TIA Portal and select your PLC

Note make sure that your device has a firmware version higher than 2.0 that contains the OPC UA.

OPC UA server from S7-1500 PLC

Step 2:

From device properties, activate the OPC UA server because by default it is deactivated, and you can copy the server address and save it as we will need it later.

Activate OPC UA Server

Step 3:

From here you can select the server license that you have installed on your PC.

OPC UA Runtime License

Step 4:

Now you can save your project and download it using PLCSIM Advanced.

S7 PLC SIM Advanced Control Panel

Note if you want to simulate the OPC server on your PC you have to use PLCSIM-Advanced, as PLCSIM will not help you.

Step 5:

Now we will go to the Indusoft SCADA software to launch an OPC client from the software. Here we will insert a new OPC-UA connection.

Open Indusoft SCADA software

Step 6:

Now you will need to copy your server TCP/IP address as shown from TIA.

copy your server TCP IP address from TIA Portal

Step 7:

Now you can paste the server address in the SCADA system and check if the connection is healthy or not.

Simulating OPC

Step 8:

Now you can add a new page to connect some tags with OPC nodes.

Connect tags with OPC nodes

Step 9:

After creating this page now, you can select the OPC connection and write your system tags.

Indusoft OPC SCADA

Step 10:

Here you can browse for your PLC nodes (tags) to attach them and to connect them with the SCADA tags.

How to Connect PLC with SCADA System via OPC UA

So, that it.

If you liked this article, then please subscribe to our YouTube Channel for PLC and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • OPC Communication
  • PLC to PLC Communication
  • Servo Motor and Stepper Motor
  • PLC and SCADA Softwares
  • Motor Stop Interlock in PLC
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

SAVE and BR Memory Instructions in Siemens PLC Programming
PLC Programming: Sorting and Distribution of Boxes by Height
PLC Program for Alternate Output Circuit with Latched Function
What is 21 CFR in SCADA and HMI Systems?
Label the Electrical Circuit Schematic
How to Solve Electrical Ground Loop Problems?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What is Alarm Prioritization? – Types of Alarms
PLC Configuration of Profinet I/O System
PLC Programming Examples on Industrial Automation
How to choose between PLC and DCS Systems ?
Real-time PLC Projects – Industrial Automation
CX-Programmer Tutorial: 1 Button To Activate 4 Different Machines
Motor Classic Control Circuits using Single Push button
PLC Program for Alarm Indication in Process Control

Keep Learning

Trolley and hoist PLC control

PLC Crane Movement Control with Limit Switches

PLC Program using Timers

PLC Timers Program

PLC Sizes and Applications

PLC Sizes and Applications

Understanding the Scan Cycle of SIEMENS PLC

Understanding the Scan Cycle of SIEMENS PLC

System Architecture in Industrial Automation

How to Design a System Architecture in Industrial Automation?

HMI Screen Design for Hazardous Applications

HMI Screen Design for Hazardous Applications

Gas Turbine Temperature Control using Siemens Tia Portal

Gas Turbine Temperature Alarms using Siemens TIA Portal

Top 5 Advantages of Human-Machine Interface (HMI)

Top 5 Advantages of Human-Machine Interface (HMI)

Learn More

What is a Process Alarm

What is a Process Alarm? Types of Alarms

Piping Schematic for Two Solenoid Valves Double Acting

Different Types of Control Valve Actuators

Pressure and Instrumentation MCQ - Questions & Answers

Pressure and Instrumentation MCQ – Questions & Answers

Turbine-Compressor System Architecture

Turbine-Compressor System Architecture

Calculate DPT Calibrated Range

Calculate the Transmitter Values

NO NC Contact Animation

Equivalent Logic Gates using PLC Ladder Diagrams

Question on Analytical Controller

Question on Analytical Controller

Instrumentation and Control Engineer Subject

Competency Factors of Instrument & Control Engineer (Design Engineering)

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?