Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Inspection and Test Requirement of Control Valves
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Valves > Inspection and Test Requirement of Control Valves

Inspection and Test Requirement of Control Valves

Last updated: June 1, 2019 8:08 pm
Editorial Staff
Control Valves
No Comments
Share
2 Min Read
SHARE

Inspection and Test Requirement of Control Valves

  • Visual Test as per MSS SP-55
  • Dimensional Test:
    • Face-to-face dimensions as per ANSI/ISA-75.08.01, ANSI/ISA-75.08.06, and ASME B16.10.
    • Flange facings and dimensions as per ASME B 16.5
  • Check of Body Marking as per ASME B 16.5, ASME B 16.34, and MSS-SP 25.
  • Chemical analysis and mechanical properties as per the applicable ASTM material code
  • Nondestructive test as per ASME B 16.34
  • Hydrostatic test as per ASME B 16.34 or MSS-SP61
  • Seat leakage test as per ANSI/FCI 70-2.
  • Actuator Leakage Test at 1.5 times maximum design pressure.
  • Functional and Performance test (i.e. hysteresis plus deadband, linearity, repeatability, etc) as per IEC 60534-4 and ISA 75.13.01
  • For electrical accessories (such as solenoid valve, I/P positioner, position transmitter etc):
    • Functional Test
    • Electrical type and routine test as per IEC 61010-1

Inspection of Control Valves

Contents
Inspection and Test Requirement of Control ValvesApplicable Standards and Codes of Control Valves :

Applicable Standards and Codes of Control Valves :

MSS SP-55

Quality Standards for Steel Castings for Valves, Flanges, Fittings and Other Piping Components – Visual Method for Evaluation of Surface Irregularities.

IEC 60534-3-1

Industrial-Process Control Valves – Part 3-1: Dimensions – Face-to-Face Dimensions for Flanged, Two-Way, Globe-Type, Straight Pattern and Centre-to-Face Dimensions for Flanged, Two-Way, Globe-Type, Angle Pattern Control Valves

ASME B 16.10

Face-to-Face and End-to-End Dimensions of Valves

ASME B 16.5

Pipe flanges and flanged fittings NPS 1/2 through NPS 24 metric/inch standard

ASME B 16.34

Valves – Flanged, threaded and welding ends

MSS-SP61

Pressure Testing of Valves

ANSI/FCI 70-2

Control Valve Seat Leakage

MSS-SP 25

Standard Marking System for Valves, Fittings, Flanges, and Unions

IEC 60534-4

Industrial-Process Control Valves – Part 4: Inspection and Routine Testing

ISA 75.13.01

Method of Evaluating the Performance of Positioners With Analog Input Signals and Pneumatic Output

IEC 61010-1

Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements.

Articles You May Like :

Types of Valve Leakage Tests

Classification of Control Valves

Valve Questions and Answers

Double-ported Globe Valve

JT Valve Working Principle

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Purpose of 100% and 30% Feed Control Valves in a Power Plant
Effect of Differential Pressure on Control Valve Lift
Difference between Blowdown Valve (BDV) and Shutdown Valve (SDV) ?
What is a Pneumatic Cylinder?
Common Terms Used in Control Valves
Types of Pneumatic Valves : Poppet & Spool
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

What is Instrument Air Manifold ?
Basic Steps and Procedure for the Repair of Control Valve
Difference between RTJ and T&G Flange Facings
How Globe Valves Work ?
ON OFF Valve Preventive Maintenance and Testing Procedure
Calculate Flow Coefficient Kv of Solenoid Valve
Different Types of Control Valve Actuators
Rotork Motor Operated Valve Basic Configuration

Keep Learning

BALL CHECK VALVE THEORY

Types of Check Valves

On-Off Valve Problems

How to Solve On-Off Valve Problems?

Valve Basics, Sizing, and Actuators Books

Valve Basics, Sizing, and Actuators Books

Reduce Control Valve Noise

How to Reduce the Control Valve Noise?

What is Travel Stop in Control Valve

What is Travel Stop in Control Valve?

Basics of Butterfly Valves

Why Restriction Orifice is some distance from Blowdown valve

Why Restriction Orifice is some distance from Blowdown valve ?

Solving Critical Control Valve Hunting

Solving Control Valve Hunting: Instrument Troubleshooting

Learn More

Pressure Transmitter Impulse Lines Heat Trace

Pressure Transmitters Heat-traced impulse lines

Reliability Centered Maintenance (RCM)

What is Reliability Centered Maintenance? (RCM)

Sensors & Transducers Questions and Answers

Top 100 Sensors & Transducers Questions and Answers for Freshers

DC Circuit

Main differences between Sinking and Sourcing Circuits

Allen-Bradley PLC Program

Troubleshoot Allen Bradley PLC Logic

Track PLC Operating Modes

#2 PLC Best Practices – Track Operating Modes

Differences Between AC and DC Motors

Instrument Mechanic Interview Questions

Instrument Mechanic Interview Questions

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?