Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Hot Wire Anemometer Principle and Types
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > Hot Wire Anemometer Principle and Types

Hot Wire Anemometer Principle and Types

Hot Wire Anemometer works when a heated wire is placed in a flowing gas stream, heat is transferred from the wire to measure flow rate.

Last updated: November 2, 2023 9:33 am
Editorial Staff
Flow Measurement
No Comments
Share
4 Min Read
SHARE

Hot Wire Anemometer works When an electrically heated wire is placed in a flowing gas stream, heat is transferred from the wire to the gas and hence the temperature of the wire reduces, and due to this, the resistance of the wire also changes. This change in resistance of the wire becomes a measure of flow rate.

Contents
Hot Wire Anemometer PrincipleTypes of Hot wire AnemometerConstant current method Hot wire AnemometerConstant temperature method Hot wire Anemometer

Hot Wire Anemometer Principle

Hot wire Anemometer Principle

The main parts of the arrangement are as follows:

  • Conducting wires placed in a ceramic body.
  • Leads are taken from the conducting wires and they are connected to one of the limbs of the wheat stone bridge to enable the measurement of change in resistance of the wire.

Types of Hot wire Anemometer

There are two methods of measuring flow rate using an anemometer bridge combination namely:

  • Constant current method
  • Constant temperature method

Constant current method Hot wire Anemometer

Constant current method Hot wire Anemometer Principle

The bridge arrangement along with the anemometer has been shown in diagram. The anemometer is kept in the flowing gas stream to measure flow rate.

A constant current is passed through the sensing wire. That is, the voltage across the bridge circuit is kept constant, that is, not varied.

Due to the gas flow, heat transfer takes place from the sensing wire to the flowing gas and hence the temperature of the sensing wire reduces causing a change in the resistance of the sensing wire. (this change in resistance becomes a measure of flow rate).

Due to this, the galvanometer which was initially at zero position deflects and this deflection of the galvanometer becomes a measure of flow rate of the gas when calibrated.

Constant temperature method Hot wire Anemometer

Constant Temperature method Hot wire Anemometer Principle

The bridge arrangement along with the anemometer has been shown in diagram. The anemometer is kept in the flowing gas stream to measure flow rate.

A current is initially passed through the wire.

Due to the gas flow, heat transfer takes place from the sensing wire to the flowing gas and this tends to change the temperature and hence the resistance of the wire.

The principle in this method is to maintain the temperature and resistance of the sensing wire at a constant level. Therefore, the current through the sensing wire is increased to bring the sensing wire to have its initial resistance and temperature.

The electrical current required in bringing back the resistance and hence the temperature of the wire to its initial condition becomes a measure of flow rate of the gas when calibrated.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Orifice Flow Meters Compensation
  • Annubar Flow Meter Theory
  • Magnetic flow meter Operation
  • Nutating Disc Flow Meters
  • What is a Thermal flow meter?
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Heat Tracing Problems
Interferometer Principle
What is Water Cut Meter?
Orifice Sizing Guidelines and Thumb Rules with Flowchart
Importance of Flow Meter Turndown Ratio
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

Types of Flow Meters MCQ - Instrumentation and Control

Types of Flow Meters MCQ – Instrumentation and Control

Flow Meter Hook Up

Flow Meter Installation Guidelines

Thermal Mass Flowmeter Principle

Thermal Mass Flow Meter – Principle, Advantages, Applications

Difference between Fixed Area and Variable Area FlowMeters

Difference between Fixed Area & Variable Area FlowMeters

Turbine Flow Meter Animation

Turbine Flow Meter – Principle, Advantages, Disadvantages

Demystifying Reynolds Number

Why Viscosity is Not Included in the Orifice Equation?

Flow Switch Symbol

Principle of Flow Switch

Turbine Flow meter coefficient

Turbine Flow Meter Coefficient and Scaling Factor

More Articles

Valve Seat leakage Test

Valve Seat Leakage Test

nuclear magnetic resonance (NMR) spectroscopy

Pharmaceutical Industry: The Role of Precision Tools

Power Plant Process Interlock for SA Fan I, & II

Boiler Safety and Process Interlocks – Power Plant Tutorials

Top 100 Switchgear and Protection Interview Questions

Top 100 Switchgear and Protection Interview Questions

Burner Control Loop Graphics

Burner Safety Logic for Initial Lighting

PLC engineering software

How to Download GX Works? Mitsubishi PLC Software

Thermocouples

Thermocouples

PLC Circuit Answers

PLC connected to Three Pushbutton Switches

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?