Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: 4-wire Passive versus Active Transmitters
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > 4-wire Passive versus Active Transmitters

4-wire Passive versus Active Transmitters

Last updated: May 9, 2019 7:30 pm
Editorial Staff
Control Systems
2 Comments
Share
2 Min Read
SHARE

4-wire “passive” versus “active” output transmitters

Some self-powered (4-wire) analog electronic transmitters are designed to behave as electrical loads rather than as electrical sources. Such transmitters are commonly referred to as having passive or sinking 4-20 mA outputs, as opposed to the active or sourcing 4-wire transmitters previously described:

Four Wire HART Transmitters

At first this seems needlessly confusing. Why build a self-powered transmitter requiring a second power supply in the circuit to drive the 4-20 mA signal? The reason for this type of transmitter’s existence is the sheer popularity of loop-powered 2-wire 4-20 mA transmitters. Loop-powered field instruments have become so popular in industry that many control systems, PLCs, indicators, and other receiving devices have their own loop power supply built in so that these systems can only connect to loads and are therefore incompatible with current-sourcing 4-wire transmitters. Thus, “passive” or “sinking” 4-wire transmitters were developed to accommodate control systems designed to work (only) with loop-powered instruments.

Some 4-wire transmitters are configurable for either passive or active (i.e. sinking versus sourcing) operation, requiring the installing technician to pay close attention in order for the circuit to properly function.

Credits : by Tony R. Kuphaldt – Creative Commons Attribution 4.0 License

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

What is FAT and SAT? Difference between them
Difference Between SCADA and HMI
Network Switch Requirement in SCADA and DCS Architecture
Open Loop and Closed Loop Animation
Alarm Simulator for Annunciator Logic
PLC Alarm and Trip Documentation
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
2 Comments
  • Preyas says:
    November 1, 2017 at 3:41 pm

    Hi,
    Can you please share the internal circuit for 4wire active type transmitter?

    Reply
  • husasain says:
    April 25, 2018 at 5:48 pm

    uhhh every day is fight in our refinery about active or passive ;))

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Basics of Grounding
Foundation Fieldbus – Advantages, Limitations, Architecture
Process Control Instrumentation Glossary
What is a Patch Panel? Types and Uses in Networking
Building Management System
Runaway Processes
Switches, Repeaters, Bridges, Routers, Firewalls
Why 24 Volts DC Power Supply is used? – Industrial Automation Systems

Keep Learning

DCS Marshalling Cabinet Checks

PLC, DCS, and ESD Marshalling Cabinet Checks

Concept of DCS in Industrial Automation

Concept of DCS in Industrial Automation

What is Timeout in Communication Protocols

What is Timeout in Communication Protocols?

main controller fails

How does a Redundant Controller comes in line when the Main Controller fails?

PID Controller Functionality

PID Controller Theory

Instrumentation and Control Project Packages

Instrumentation and Control Project Packages – Detail Engineering

Turbine Bypass System

Turbine Bypass System

controller integral wind-up

Limit Controls : High Limit & Low Limit Functions

Learn More

Electrical Maintenance Engineer's Biggest Enemy

Electrical Components Overheating – Causes, Troubles, Prevent

Analyzers Questions and Answers

Ionization of Gases Questions and Answers

PN Junction Questions & Answers

PN Junction Questions & Answers

Electrical Machines Questions and Answers

Armature Quiz

Identify Valve Parts Quiz with Answers

Identify Valve Parts Quiz with Answers

HMI Simulation for PID Controller

PID Controller Output Types – PID_PWM and PID_Output

What is VLAN?

Difference Between Subnet and VLAN

Distribution transformer

Types of Transformers

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?