Inst ToolsInst ToolsInst Tools
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: How to Convert Cable Size from AWG to Inches
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Formulas > How to Convert Cable Size from AWG to Inches

How to Convert Cable Size from AWG to Inches

Last updated: April 13, 2019 5:31 pm
Editorial Staff
Formulas
No Comments
Share
0 Min Read
SHARE

How to Convert Cable Size from AWG to Inches ? Here is the formula for conversion of cable size from American wire gauge to inches.

Contents
Example :Convert 36 AWG of a Cable into Inches ?

The diameter of a Number n AWG wire in inches is given by :

How to Convert Cable Size from AWG to Inches

Example :

Convert 36 AWG of a Cable into Inches ?

dn=0.005×92(36-36)/39

dn=0.005×920

dn=0.005×1

dn=0.005 inches

Also Read : 4-20mA Graphical Calculations

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Siemens Differential Pressure Transmitter Calculations (Flange Type)
Zero Suppression and Zero Elevation Calculations
Open Tank DP Level Transmitter Calculations
DP Transmitter Dry Leg & Wet Leg Calculations
PLC Analog Input Scaling
Formula to Calculate 3-15psi from 4-20mA Current
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Transmitter Turndown Ratio, Set Span and Zero Span
PLC Raw Count Calculation for Pressure Transmitter
4-20mA Graphical Calculations
How is Pressure Drop Calculated through a Valve ?
Input-Output Relationships of Transmitters
Calculate Temperature Coefficient of RTD
Relationship between Temperature Scales
Formula to Calculate Process Variable from 4-20mA
Raw Counts to Engineering Units : Conversion Formula
Gas Flow Formulas

Keep Learning

Field Instrument 4-20mA Calculation

How to do 4-20mA Conversions Easily

4-20 mA Conversion Formulas

Standard 4 to 20 mA Conversion Formula

Differential Pressure Transmitter

Calculate Process Variable from 4-20mA using Fraction of Measurement

Turbine Flow meter coefficient

Turbine Flow Meter Coefficient and Scaling Factor

Displacer Level Measurement Formula

Displacer Level Measurement Calculations

Current-to-Percentage-Conversion

Formula for Current 4-20ma to Percentage Conversion

3-15 psi to 4-20mA Conversion

Example of 3-15 psi to 4-20mA Conversion

PLC Problems Troubleshooting

PLC Problems Troubleshooting

Discover More

Fieldbus Interview Questions

Interview Questions on Fieldbus Communication

HMI configuration for Delta VFD

Modbus Communication between Delta PLC with VFD

Valve Bellows seal

Bellows Seal Valve Working Principle

Faceplate in WinCC

Siemens HMI Training – Using UDTs with Faceplates

Power Electronics Objective Questions

Power Electronics Filters Questions and Answers

Vibration Sensors Theory

How Vibration sensors Work ?

Combining Independent Current Sources in Parallel

Combining Independent Current Sources in Parallel

transistor-emitter-bias

Transistor Emitter Bias

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?