Instrumentation Design

Why Orifice Flow Meter Flange is Not Recommended 150# Rating?

This question comes to mind? As to Restriction Orifice can have 150# but the Orifice flange (Flow meter) is not recommended to have a 150# rating.

Orifice Flange Rating

Orifice Flange Rating – 150#

We have the answer in one sentence.

It is due to flange integrity !

It means in simple words :- Orifice that are flange tapped have reduced strength

Due to this drilling in between them their pressure-temperature retaining capacity reduces

So to ensure flanges have Strength to withstand Design pressure and temperature a higher rating than 150# i.e 300# is used .

Now There has to be some proof supporting It !!!

The PROOF

The standard we use for Normal flanges below 24” is ASME B16.5

But for Orifice, the flange standard is ASME B16.36

This standard starts with 300# Flange rating.

In restriction Orifice as there are no tapping hence we go with ASME B16.5 flanges which Start with 150# Rating .

As always ! Thanks a lot for Reading !!

PS :- It is observed that for very large line sizes ( Depends few say above 10”, few say above 20”) 150# can be used as these flanges are stronger at higher line sizes but I have not found concrete proof in standards yet.

I would be very grateful if somebody knows the standard that has this documented.

Author: Asad Shaikh

Profile: Linkedin

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

You've successfully subscribed !

View Comments

  • which would be the best instrument to measure flow in a 4" gas line? unfortunately the gas contains condensate.

Share

Recent Articles

  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

4 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

4 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

5 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

2 days ago
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

4 days ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

4 weeks ago