Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: NH3 Storage Tanks Ammonia Gas Venting Issue – Root Cause Analysis
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > NH3 Storage Tanks Ammonia Gas Venting Issue – Root Cause Analysis

NH3 Storage Tanks Ammonia Gas Venting Issue – Root Cause Analysis

Root Cause Analysis (RCA): NH3 Storage tanks 12 T/d ammonia gas venting issue and financially cripples a fertilizer plant.

Last updated: September 28, 2022 3:19 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
4 Min Read
SHARE

Root Cause Analysis (RCA): NH3 Storage tanks 12 T/d ammonia gas venting issue and financially cripples a fertilizer plant besides attracting pollution authorities’ factory closure threat.

Contents
NH3 Storage Tanks Ammonia Gas Venting ProblemRCA Queries & AnswersFinal solutionPreparations & Package Commissioning
Article Type:Root Cause Analysis (RCA)
Category:Mechanical
Equipment Type:Miscellaneous Rotating Machine Problems
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

NH3 Storage Tanks Ammonia Gas Venting Problem

Tanks’ pressure controller constantly vented ≈ 12 t/d of NH3, to hold the tank top vapor space pressure at 300-mm WC due to poor availability of NH3 refrigeration compressors.  

RCA Queries & Answers

RCA queries and answers follow:

Q- Explain liquid NH3 storage

A-Storing liquid ammonia at -28o C at atmospheric pressure in cylindrical tanks is the most economical bulk storage method. Around 500 Kg/H NH3 evaporates from the state-of-the-art insulated 20-m tall 5000 T storage tank.

A refrigeration system draws, compresses, liquefies, and puts the liquid NH3 into the tank. The provided refrigeration system compressors’ availabilities were < 20%.

Hence, the tank pressure controller vents the gas to hold the tank pressure below the permitted 300 mm WC; hence, the plant suffered 12 T/day ammonia losses.

The author found the compressors so poorly built that improving was impossible. He recalled an ad on a screw-compressor package refrigeration system. Users’ feedback was exemplary. He ordered one package.

Final solution

Plant crew bolted the rush ordered and 4‑months hence received package skid less motor on the pre-readied foundation,

Reasons for less motor order were:

  1. A surplus 450 KW, 3000 RPM 3.3 KV motor was available in the warehouse
  2. US standard 60 Hz motors run too hot with India 50 Hz power supply
  3. Insisting on a 50-Hz motor would delay the delivery by 3 months
  4. In addition, even 50 HZ labeled US motors often run too hot in India

Preparations & Package Commissioning

  1. The plant crew readied the foundation based on the vendors package footprint drawing and loads detail.
  2. Fortunately, 2-spare breakers were available in the 3.3 KV load center. The electrical crew laid the breaker to foundation cable and readied the motor protection system

Mech crew bolted the package on the foundation within 6-hours of receipt. In addition, they bolted the 450 HP motor, aligned it, and coupled it to the package screw compressor.

The electrical crew dressed and connected the already laid cable to the motor.

The instrument crew connected the air supply to the package pressure controller, its output to the throughput control slide valve, and tuned the controller.

The package hummed within 20 hours of arrival. For the first time in ten years fully closed tank vent valve cheered everyone! The ten yearlong ammonia vapor venting ceased forever! The package was indeed a ‘fit and forget system.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Turbo-Compressor Problem
  • Compressor Anti-Surge Control
  • Process Air Compressor Overhauls
  • NH3 Plant Turbo-compressor Problem
  • Failing Plant Air Compressor Drives
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Urea Reactor Top Bolted Plug developed Leaks
Frequent Feeder-A Lightning Arrester (LA) Bursts – Root Cause Analysis
Antifriction Bearings Caused Machine Changeovers Posed Outages
Seal Pressure Instruments Root Cause Analysis
Root Cause Analysis for FRP Line Damaged due to On-Off Valve
Replace Failed Motors Quickly and Easily
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

An Indian Plants all turbines’ low Vacuum & Saudi Plant turbo-compressor only
Erratic Radar Level Gauges Delays a Refinery Commissioning
Plant Shutdown Analysis: Valve Closed and SOV Coil Failure
Centrifugal Compressor Outage Reduced – Root Cause Analysis
Many Bucket Elevator Wrecks rob crew morale
Thermowell Shank to Flange Repeat Weld Leaks
Seawater Pipeline Spools from day-1 leaks threaten Plant Shutdown
Rotary Granulator Drive Root Cause Analysis (RCA)

Keep Learning

Less than 40% available Plant Air Compressors made available 100%

Less than 40% available Plant Air Compressors made available 100% for Operations

repairs of welding cast refractory lined box over the hot spots

Too often done riskily repaired Roof Hot Spots eliminated forever

Finned Heater Leaks Sealed

Finned Tube Steam Leaks – Root Cause Analysis

Card Failures in Automation Panels

Automation Panel Electronic Cards Failure investigation

Jackshaft Belt Drive

Poorly Engineered, built & often Failing Plant Air Compressor Drives

Butterfly Valve Failure caused Fire

Butterfly Valve Failure Caused Serious vicinity Heavy Fire

Thermocouple Extension Lead Minimizer Circuit

Thermocouple Wires and Extension Lead Issues

CO2 Absorber Graphics in DCS

CO2 Absorber Corroded Wall Thickness & Weld Building

Learn More

Temperature Gauges and Elements Specifications

Temperature Gauges and Elements : Detailed Specifications

Difference Between LAN and WAN Networks

Difference Between LAN and WAN Networks

IPSec

What is IPSec? – Internet Protocol Security

Power Electronics Objective Questions

PN Junction Quiz

L2F insertion-style flowmeter

Optical Flow Meter Principle

What is a Rotary Actuator

Difference Between Linear Actuator and Rotary Actuator

Instrumentation Engineering Materials Test

Instrumentation Materials Test

Power Electronics Objective Questions

Thyristor Gating Circuits Objective Questions

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?