Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: Difference Between Alternator and Generator?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > Difference Between Alternator and Generator?

Difference Between Alternator and Generator?

In this article, we will understand the basic difference between alternator and generator.

Last updated: October 17, 2023 3:06 pm
Viral Nagda
Electrical Basics
No Comments
Share
4 Min Read
SHARE

In this post, we will understand the difference between alternator and generator.

Contents
AlternatorGeneratorDifference Between Alternator and Generator?Stationary Part and Rotary PartOutput Current and EfficiencyInput SupplyDead Battery ChargeOutput EMF and RPMSize

According to Faraday’s law, current will be induced in the conductor if it is placed in a varying magnetic field. When the magnetic field is cut, current will be produced.

In this post, we will see two mechanical devices which produce electricity. They are an alternator and generator. Both are devices that convert mechanical energy into electrical energy.

Only in this aspect, both are same in working. But, they have major differences in terms of other points. Let us have a look at the differences between an alternator and a generator. 

Before proceeding to the differences, let us first understand the working of both devices.

Alternator

An alternator has its field winding in the rotor and armature winding in the stator. A DC source is used to generate a permanent magnetic field.

So, according to Faraday’s law, as the magnetic field is intersected by the moving field windings, an emf is induced and current is thus produced.

Generator

However, in a generator, the same principle works in a reverse way. The armature winding is in the rotor and the field winding is in the stator.

Difference Between Alternator and Generator

Difference Between Alternator and Generator?

Now, we will proceed ahead to understand the differences.

Stationary Part and Rotary Part

In the alternator, the armature is stationary and the field winding is rotary. In the generator, the field winding is stationary and the armature is rotary. In either case, emf is induced as the magnetic field is generated by motion.

An alternator converts mechanical energy into AC power; whereas a generator converts mechanical energy into either AC or DC power.

Output Current and Efficiency

An alternator produces higher output current and has greater efficiency than a generator which comparatively produces less output current and has lesser efficiency.

So, an alternator generates much more energy than a generator.

Input Supply

An alternator takes the input supply from the stator whereas a generator takes the input supply from the rotor.

This is also one of the reasons that the brushes of an alternator last longer than a generator.

Dead Battery Charge

An alternator cannot charge a dead battery. This has not been tried and if you attempt to charge a battery from an alternator, there are chances that it may overheat it. But, this is not the case in a generator.

A generator can charge batteries and so, can be used to recharge dead batteries.

Output EMF and RPM

The output voltage of an alternator is variable, but the output voltage of a generator is constant.

Also, an alternator has a wide range of speed (RPM) whereas a generator has only a limited range of speed.

Size

An alternator requires less space and a generator consumes a large amount of area.

In this way, we found out that an alternator practically has more applications in electrical engineering than a generator; solely due to its many advantages.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Motor Dynamic Braking
  • DC Injection Braking in VFD
  • What is an Electrical Drive?
  • What is a Capacitor Bank?
  • Good and Bad Electrical Wiring
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !
Hazardous Areas in Industry – Electrical Equipment Selection
Difference Between Regenerative and Dynamic Braking
What is a Substation? Purpose of an Electrical Substation
Types of Earth Leakage Circuit Breaker
What is Gas-Insulated Transmission Line? Principle Advantages
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • MIHARITSOA Aina Sitraka on Top Non-PLC Certification Courses for Automation Professionals
  • Vaishnavi on Free Instrumentation Course for Trainee Engineers

Related Articles

Difference Between Permittivity and Permeability

Difference Between Permittivity and Permeability

Automatic Transfer Switch

Automatic Transfer Switch (ATS) Using Classic Control Circuit

Cleat Wiring

Types of Electrical Wiring

Simplified Induction Motor - Cross Section

Siemens Standard Drives Application Handbook (PDF)

Motor Controls

Design and Implement Motor Control – Electrical Engineering

Electrical Conduit

What is Electrical Conduit? Types, Advantages, Disadvantages

Lead Acid Battery Operation

How does a Lead Acid Battery Work?

Differences between Watts and Volt Amps

Differences between Watts and Volt Amps

More Articles

Square-Root extraction in DCS or Transmitter

Square-Root in DCS or Flow Transmitter?

Mixing Tank Relay Circuit

PLC Program for Mixing Tank

PRESSURE VARIATION CONTROL VALVe - 2

Constant Flow Valve Principle

Control Systems Questions & Answers

Control Systems Objective Questions & Answers – Set 7

Data Types in PLC

Data Types in PLC – Bit, Byte, Integer, Real, String

Closed Tank Application

Zero Elevation and Zero Suppression in Level Measurement

Double-acting cylinder - 2

Fluid Power Systems

Electrical Machines Questions and Answers

Electrical Machines Losses, Efficiency and Regulation Questions

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?