Inst ToolsInst ToolsInst Tools
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
      • Instrumentation
      • Electronics
      • Electrical
      • Practical Questions
    • MCQ
      • Instrumentation MCQ
      • Electrical MCQ
      • Electronics MCQ
      • Control Systems MCQ
      • Analog Electronics MCQ
      • Digital Electronics MCQ
      • Power Electronics MCQ
      • Microprocessor MCQ
      • Multiple Choice Questions
  • EE
    • Electronics
      • Electronics Q & A
      • Electronic Basics
      • Electronic Devices & Circuits
      • Electronics Animation
      • Digital Electronics
    • Electrical
      • Electrical Basics
      • Electrical Q & A
      • Power Electronics
      • Electrical Machines
      • Electrical Animation
      • Power Systems
      • Switchgear & Protection
      • Transmission & Distribution
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Search
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Reading: What are Static UPS and Rotary UPS?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • PLC Tutorials
  • Control Systems
Search
  • Ask
  • Courses
  • Videos
  • Q & A
    • Interview
    • MCQ
  • EE
    • Electronics
    • Electrical
  • Measure
    • Control Valves
    • Calibration
    • Temperature
    • Pressure
    • Flow
    • Level
    • Analyzers
    • Switches
    • Vibration
    • Solenoid Valve
  • Control
    • PLC Tutorials
    • Control Systems
    • Safety Instrumented System (SIS)
    • Communication
    • Fire & Gas System
  • More
    • Design
    • Tools
    • Animation
    • Basics
    • Formulas
    • Standards
    • TextBooks
    • Common
    • Software
    • Excel Tools
    • Erection & Commissioning
    • Process Fundamentals
    • Videos
    • Books
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > What are Static UPS and Rotary UPS?

What are Static UPS and Rotary UPS?

In this article, we will learn the basic types of uninterruptible power supply. They are static UPS and dynamic rotary UPS.

Last updated: October 17, 2023 1:53 pm
R Jagan Mohan Rao
Control Systems Electrical Basics
No Comments
Share
7 Min Read
SHARE

According to the energy storage and the means of energy conversion, the uninterruptible power supply systems are in general classified as

Contents
Compare Static UPS and Rotary Dynamic UPSStatic UPSs also have drawbacksWhat are the Defining Features of a Static UPS?What are the Main Characteristics of Dynamic UPS?Static UPS or Dynamic UPS?Initial investmentMaintenance costEnvironmental impactReliabilityWhat Power and Performance does each UPS offer?
  • Static UPS
  • Rotary or Dynamic UPS

In static UPS, storage of energy is made in electrochemical batteries (secondary sources) and also the required conversions of electrical power are performed by semi-conduction electro converters, which do not consist of moving parts and are classified as static ones.

The selection of the best-uninterrupted power supply system (UPS) will depend on the power required, the investment capacity for the project, and the type of design that gives us greater availability.

Rotary UPSs are less likely to fail and are more energy-efficient, although more expensive.

Static UPS allows us to work with less initial investment compared to rotary one.

Static Online UPS
Figure: Static UPS

Compare Static UPS and Rotary Dynamic UPS

An important point to compare is efficiency.

Static UPSs require less investment at startup, we can expand the equipment in a modular way, even working in parallel.

Static UPS systems require air conditioning systems, necessary to maintain in between 20 deg to 25 deg C, with efficiencies of 95-97% of the dynamic versus 94-96% of the static.

Operating costs show that it is more economical to maintain rotating UPS systems. On the one hand, dynamic UPS systems are involved in higher cost, much space, venting facility is required.

Static UPSs also have drawbacks

Static UPS systems are made up of a large number of elements, which increases the chances of failure.

They also need auxiliary elements, cleaning, and batteries.

They withstand less short-circuit intensity than the dynamic ones.

What are the Defining Features of a Static UPS?

They are called static UPS because their operation does not require moving mechanical elements (except fans).

They use power electronics to convert alternating voltage into direct voltage by means of semiconductors and have stored the necessary energy to deliver, in the event of a power failure, in accumulator batteries.

Static UPSs have a wide range of powers, which allow dimensioning solutions from 500 VA to 1.6 MW per unit, and with the possibility of parallel operation.

In addition, there is modular equipment on the market that allows scalability as the user grows, adapting the investment to each particular situation, which represents a great advantage for data center users.

What are the Main Characteristics of Dynamic UPS?

Dynamic or rotating equipment has a synchronous electric motor in motion that transforms electrical energy into mechanical energy or vice versa in its operation as an alternator.

In addition, they have the necessary energy stored, to deliver in case of supply failure, as kinetic energy in a flywheel.

The autonomy time is a few seconds and therefore it is suitable to protect itself from gaps and micro-cuts.

But when we want to protect ourselves from power outages, it is necessary to install an additional motor (normally diesel) coupled to the dynamic UPS, or to a plant. An emergency generator that ensures continuity.

Although there are static solutions on the market, the use of dynamic equipment is more typical when the requirements of the UPS are outdoor installations and in medium voltage applications.

Rotary UPS or Dynamic UPS
Figure: Rotary Dynamic UPS

Static UPS or Dynamic UPS?

At what point should we opt for a static UPS or a dynamic one in large loads?

A precise engineering study is required, calculating investment and operating costs to be able to opt for a solution of static or dynamic equipment.

Various factors to be analyzed are:

Initial investment

Rotary UPSs represent a high investment cost, they are typically not modular, so initially, they will have to be oversized to prevent future growth of the critical load.

Maintenance cost

The rotary UPS intrinsic to mechanical elements in continuous movement contributes to bearing wear, brushes, flywheel, clutch, etc. As well as preventive adjustments, greasing, ventilation, cleaning, etc.

Static UPS at a preventive level of adjustments, cleaning, replacement of control cards, as well as replacement of elements that lose their useful life, such as fans, power storage batteries.

Environmental impact

Generally, static UPSs are installed indoors, in the partitioned room itself, or in particular rooms. If open batteries are used, proper rooms must be allotted for a possible accumulation of hydrogen gas, with the resultant danger of fire/explosion.

The rotary UPS systems are installed outside or in rooms assigned to them. They require a suitable location taking into account the audible noise they generate, weight, vibrations, and the need for ventilation and expulsion of the exhaust gases, more maintenance, as well as the possible risk of fire from the fuel.

Reliability

Both systems are reliable solutions, a comparison must be made according to the projected configuration.

What Power and Performance does each UPS offer?

From the POWER point of view, on the market, there are static UPSs generally small UPS, Medium UPS, large UPS systems up to 2 MW.

The rotary UPS generally can be found in a range between 300 kW to 2 MW. Units are also found in KVA.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • UPS Selection Factors
  • What is a Soft Starter?
  • Overload Relay Principle
  • Compare HV and LV Cables
  • How to Test Motor using Megger?
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Recommended Articles

What is an Intelligent Motor Control Center? – IMCC
What are Analog and Digital Signals? Differences, Examples
Square-Root in DCS or Flow Transmitter?
Fault in the Temperature Loop
Interposing Relay Panel (IRP) – Wiring and Testing Requirements
How Motor Star Delta Starter Works ?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
208kSubscribersSubscribe
38kFollowersFollow

Categories

Recent Comments

  • William Snyder on Top Non-PLC Certification Courses for Automation Professionals
  • Kamli on Top Free PLC Software
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals
  • Guifty Shimica on Top Non-PLC Certification Courses for Automation Professionals

Related Articles

Siemens PCS 7

What is PCS 7?

DDE Protocol

What is the DDE Protocol?

Feed forward example

What is Feedforward Control ?

HART Transmitters Loop Checks

Loop Check of 4-20mA or HART Transmitters

Control systems in industrial projects

Interactions With Process Control Systems Philosophy

Field Instrument package

Package System Architecture – Control & Instrumentation

Unmanaged Switch

Managed Switch vs Unmanaged Switch

Single-element drum level control system

Single Element Drum Level Control System

More Articles

Energy Meter Data in PLC using Modbus Communication

Modbus Communication between PLC and Energy Meter

Diaphragm Seal Transmitters Errors

Diaphragm Seal Transmitters Errors

AI AO DI DO Signals

What are AI, AO, DI, and DO? – Definition, Examples, Purpose

Analog to Digital Converters Objective Questions

Analog to Digital Converters Objective Questions

Tomography Objective Questions

Tomography Objective Questions

Power Electronics Objective Questions

Power Transistor Objective Questions

Interview Questions on Electronics and Instrumentation

Interview Questions on Electronics and Instrumentation

Ziegler-Nichols Closed Loop Tuning Procedure

Ziegler-Nichols Closed Loop Tuning Procedure

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?