Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: How to use Simulator in Siemens PLC?
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > PLC Tutorials > How to use Simulator in Siemens PLC?

How to use Simulator in Siemens PLC?

Last updated: March 4, 2021 12:30 pm
Editorial Staff
PLC Tutorials
No Comments
Share
3 Min Read
SHARE

The simulator is used when you don’t have an actual PLC and you want to test the logic, It acts as a virtual PLC.

In the last article, I have explained a method to create a new project using a Siemens Simatic manager.

Here, in this article, I will explain how to use the simulator in siemens plc, works the same in both Simatic manager and TIA portal if you have selected CPU-300 or 400.

Also Read:

  1. Download Siemens PLC Software
  2. Create a New Project in Siemens PLC
  3. Example PLC Programs and Tutorials

Simulator in Siemens PLC

Here, I will create a program for high and low-level detection and work with a simulator.

  1. Open the Siemens programming environment.
  2. write the program.
How to use Simulator in Siemens PLC

Here I0.0 is used for Low-level switch,

I0.1 is used for the high-level switch,

Q0.0 is used for the pump.

When the level is low then the low-level switch will energize and makes the pump run. Here, the pump is latched to provide continuous signal flow.

When the level reaches to a High level due to NC contact it Won’t allow the signal to pass and make pump OFF till it can’t get back to a low level.

  1. Let’s run this logic using the simulator. Follow the below step to run the simulator.

In Simatic manager go to “option” and hit click on “set PG/PC interface”

Siemens PLC simulation
  1. Following window will pop-up. Here, select PLCSIM.MPI to work in the simulator.

You can select another option if you have connected It with actual PLC as per the network you have used for your application.

Hit “ok” will load the selected option.

Siemens PLC SIM
  1. Select option simulation on/off as shown in the below window.
Siemens Offline Simulation
  1. From “insert” you can add input and output variable.
siemens plc simulator
  1. Now let’s download the program to the simulator. Select “Simatic 300” and click on “download icon”
Plc simulator siemens free download

Here, in the simulator, as shown in a red mark change it with PLC SIM (MPI) from TCP/IP otherwise it won’t work.

  1. After downloading In OB environment select icon with “spectacle”.

In the simulator choose ”Run” or “Run-P” mode and test the logic.

S7 PLC Simulator
  1. At low-level pump is on
Siemens PLC Simulator and Plant Simulation Software
  1. When the level reaches a high-level and it will turn OFF the pump.
Siemens Simatic PLC Step7 Simulation

Author: Suhel Patel

If you liked this article, then please subscribe to our YouTube Channel for PLC and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Troubleshoot PLC Program
  • Protect PLC using Password
  • PLC Maths Instructions
  • Siemens PLC Backup
  • Siemens S7 1200 PLC
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

How to Work With Simulator in S7-1200 and S7-1500 PLC?
Single Push button to ON and OFF a Bulb using Ladder Logic
Ferrules and Cross Ferruling
Control Loops Objective Questions and Answers
Cars Garage Counter From the Same Door PLC Logic
PID Controllers in Closed Loop Control Systems – PLC Basics
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Example of Flip-Flop PLC Program for Lamps Application
PLC Alarm and Trip Documentation
If Else Statement in SCL Language
Why Baud Rate is Important in Modbus Network?
PLC Temperature Control using Pulse Width Modulation (PWM)
PLC Program for Artificial Fishpond Water Level Monitoring System
PLC Program for Sequential Motor Control
Scheduled Daily Plant Watering PLC Program

Keep Learning

Types of Noise in Electronics

Types of Noise in Electronics

PLC Engineers Interview Questions

PLC SCADA Engineers Interview Questions and Answers

Color detection PLC logic

Conveyor Sorting System with Color Detection PLC Logic

Siemens CP Module

Communication Processor Module in Siemens PLC

Gas Turbine Temperature Control using Siemens Tia Portal

Gas Turbine Temperature Alarms using Siemens TIA Portal

What is Ladder Diagram Programming ?

Actuator Sensor Interface (ASi) Protocol in PLC

Actuator Sensor Interface (ASi) Protocol in PLC

Comparison of Proportional Integral Derivative Controllers (PID)

Comparison of Proportional Integral Derivative Controllers (PID)

Learn More

volumetric flow measurement for liquids versus gases

Standardized Volumetric Flow

Hazardous Area Classification Comparison

Comparison of IEC & NEC Area Classifications

Volume Booster Working Principle

Control Valve Volume Booster Working Principle

Series-Wound DC Generator Principle

Series-Wound DC Generators

Digital Electronics Objective Questions

Digital Electronics Objective Questions – Set 11

Free WinCC SCADA Training Course

Free SCADA Training Course

Analytical Measurement Multiple Choice Questions

Analytical Measurement Multiple Choice Questions

diodes-questions-answers

Diodes Questions & Answers

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?