Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Example of Feedback System
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > Example of Feedback System

Example of Feedback System

Last updated: July 13, 2019 12:52 pm
Editorial Staff
Control Systems
No Comments
Share
3 Min Read
SHARE

Home furnace control system must control the temperature in the room and kept it constant.

As in open loop system a timer is used to switch on the furnace for some time and then switch it off, accuracy is not obtained.

This is because the system does not act according to the room temperature but according to a preset value of time.

Example of feedback principle

A closed loop control system takes care of this problem. The feedback unit (the main component of the closed loop control system) senses the room temperature and accordingly turns on or off the furnace.

The feedback unit feeds the output back to a comparator which is provided with a reference value with which the output is compared to generate an error signal. This error signal generates the required control action.

In the home furnace control system, a temperature sensor is used to sense the temperature in the room and this is feedback to an error detecting device. The error detecting device compares the room temperature with the reference value.

If it detects that the room temperature is higher than the reference value, if generates a signal to switch off the furnace. On the other hand, if it detects that the room temperature is lower than the reference value, it generates a signal to switch on the furnace. This has been shown in the figure.

Hence it is clear that a system with feedback (closed loop control system) is efficient than that of a system without feedback (open loop control system).

Human Control System

Another examples of a closed loop control system is the working of a human brain. If a person wants to pick up an article say bag or book, the brain instructs the hand to reach the article and the eyes constantly keep giving the feedback to the brain regrading the posistion of the hand relative to the article.

But if the person is asked to reach the article closing his eyes, he can reach it only approximately. Thus the human system is a very accurate feedback control system. The control system taking human as an example is shown in the figure.

While designing a closed loop system, a compromise between stability and accuracy is to be established. This is because the gain of the system may exceed over a limit which may cause the system to be over correct, leading the system to become unstable, that is, oscillation of the output without bound.

Note

Gain is the ratio between the amplitude of the output to the amplitude of input. The variation of the gain over a range of the frequencies is called frequency response. Moreover, due to mechanical problems like friction, the system might tend to have a steady state error.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

PLC Alarm and Trip Documentation
Overview of Industrial Control Systems
Types of Cables used in Industrial Automation
What is Electromagnetic Noise Interference?
What is Loop Checking?
Control Room Design Guidelines
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Power Supply Sizing for Industrial Automation Systems
Process Switches and Alarms
VFD Simulator Download – Free Yaskawa V1000 Software
Remote Connectivity to Industrial Automation Systems
Voting Concept in Package Safety System
Siemens PLC Course for Beginners: Problems and Solutions
SCADA Systems
Anti Surge Controller Working Principle

Keep Learning

Certified Control Systems Technician (CCST) Sample Questions

Certified Control Systems Technician (CCST) Questions

DCS ESD Logic Overview Graphic Display

Automation System Process Functionalities

Enterprise Resource Planning in Industrial Automation

What is ERP in Industrial Automation? – Enterprise Resource Planning

Motor Controls

Design and Implement Motor Control – Electrical Engineering

VPN for Control Engineers

How Important is VPN for Control Engineers?

Project Planning and Implementation of PLC or DCS Control System

Project Planning and Implementation of PLC or DCS Control System

ICS Control System

ICS Control System Security

DCS Troubleshooting Control Valve Loop

DCS Troubleshooting Control Valve Loop

Learn More

Bimetallic Thermometer

Bimetallic Thermometer

100+ Quiz on Electrical Circuits and Control

100+ Quiz on Electrical Circuits and Control

Top 100 PLC Projects List

Top 100 PLC Projects List

5 Valve manifold

5 Valve Manifold Operation

Instrumentation Engineer’s Calibration Mistakes

Multiplexing

Introduction to Digital Systems

cavitation-control valve trim

What is Control Valve Cavitation ?

Solenoid Valve Problems and Solutions

Solenoid Valve Problems and Solutions

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?