Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Laminar Flow Meter Working Principle
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Flow Measurement > Laminar Flow Meter Working Principle

Laminar Flow Meter Working Principle

A unique form of differential pressure-based flow measurement deserves its own section in this flow measurement chapter, and that is laminar flow meter.

Last updated: November 2, 2023 7:26 am
Editorial Staff
Flow Measurement
No Comments
Share
5 Min Read
SHARE

A unique form of differential pressure-based flow measurement deserves its own section in this flow measurement chapter, and that is the laminar flow meter.

Contents
Laminar FlowLaminar Flow MeterAdvantages of Laminar Flow MeterDisadvantages of Laminar Flow MeterApplications of Laminar Flow Meter

Laminar Flow

Laminar flow is a condition of fluid motion where viscous (internal fluid friction) forces greatly overshadow inertial (kinetic) forces. A flow stream in a state of laminar flow exhibits no turbulence, with each fluid molecule traveling in its own path, with limited mixing and collisions with adjacent molecules.

The dominant mechanism for resistance to fluid motion in a laminar flow regime is friction with the pipe or tube walls. Laminar flow is qualitatively predicted by low values of Reynolds number.

This pressure drop created by fluid friction in a laminar flow stream is quantifiable, and is expressed in the Hagen-Poiseuille equation:

Laminar flow meter equation

Where,
Q = Flow rate
ΔP = Pressure dropped across a length of pipe
D = Pipe diameter
μ = Fluid viscosity
L = Pipe length
k = Coefficient accounting for units of measurement

Laminar flow meter elements generally consist of one or more tubes whose length greatly exceeds the inside diameter, arranged in such a way as to produce a slow-moving flow velocity.

Laminar Flow Meter

An example is shown here:

Laminar Flow Meter Working Principle

The expanded diameter of the flow element ensures a lower fluid velocity than in the pipes entering and exiting the element. This decreases the Reynolds number to the point where the flow regime exhibits laminar behavior.

The large number of small-diameter tubes packed in the wide area of the element provide adequate wall surface area for the fluid’s viscosity to act upon, creating an overall pressure drop from inlet to outlet which is measured by the differential pressure transmitter.

This pressure drop is permanent (no recovery of pressure downstream) because the mechanism of pressure drop is friction: total dissipation (loss) of energy in the form of heat.

Another common form of laminar flow element is simply a coiled capillary tube: a long tube with a very small inside diameter. The small inside diameter of such a tube makes wall-boundary effects dominant, such that the flow regime will remain laminar over a wide range of flow rates.

The extremely restrictive nature of a capillary tube, of course, limits the use of such flow elements to very low flow rates such as those encountered in the sampling networks of certain analytical instruments.

Advantages of Laminar Flow Meter

A unique advantage of the laminar flowmeter is its linear relationship between flow rate and developed pressure drop.

It is the only pressure-based flow measurement device for filled pipes that exhibits a linear pressure/flow relationship.

This means no “square-root” characterization is necessary to obtain linear flow measurements with a laminar flowmeter.

Disadvantages of Laminar Flow Meter

The big disadvantage of this meter type is its dependence on fluid viscosity, which in turn is strongly influenced by fluid temperature.

Thus, all laminar flowmeters require temperature compensation in order to derive accurate measurements, and some even use temperature control systems to force the fluid’s temperature to be constant as it moves through the element.

Applications of Laminar Flow Meter

Laminar flow elements find their widest application inside pneumatic instruments, where a linear pressure/flow relationship is highly advantageous (behaving like a “resistor” for instrument air flow) and the viscosity of the fluid (instrument air) is relatively constant.

Pneumatic controllers, for instance, use laminar restrictors as part of the derivative and integral calculation modules, the combination of “resistance” from the restrictor and “capacitance” from volume chambers forming a sort of pneumatic time-constant (τ ) network.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Flow Measurement Technologies
  • What is a Vortex flow meter?
  • PLC Program for Flow Totalizer
  • What is an Insertion flow meter?
  • Turbine Flow meter Coefficient
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

What is a Weigh Feeder?
Types of Vortex Flow Meter Sensors
What is a Ultrasonic Flow Meter?
Flow Meter Installation Guidelines
Pitot Tube Problems and Troubleshooting Steps – Flow Instrument
What Factors Affect the Stability of Flow Meter Readings?
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Orifice Sizing Guidelines and Thumb Rules with Flowchart
Magnetic Flow Meters Installation Guidelines
What is a Positive Displacement Flow Meter?
Dall Tube Flow Meter – Principle, Advantages, Disadvantages
DP type Flow Transmitter Preventive Maintenance and Calibration
Calculate Flow Transmitter Output Current
Flow Meter Calibration
Is it Easy to Measure Natural Gas Flow and Volume?

Keep Learning

Oscillating Piston Flow Meters Principle Animation

Nutating Disc Flow Meters Working Principle

Measuring Instruments

Flow Instruments – Selection, Principle & Application

Orifice Flange Rating

Why Orifice Flow Meter Flange is Not Recommended 150# Rating?

Turbine Meter Custody Transfer

What is Gas Meter and Regulating Station?

Turbine Flow Meter Calibration

How to do Turbine Flow Meter Verification?

Thermal Dispersion Flow Switch Working Principle

Thermal Dispersion Flow Switch Working Principle

Flow Switch Principle

In-Line Flow Switch Working Principle and Animation

difference between invasive and non-invasive and intrusive and non-intrusive

Difference between Invasive, Non-invasive, Intrusive & Non-intrusive

Learn More

Comparison of Level Meters - Level Measurement Instruments

Comparison of Level Meters – Level Measurement Instruments

PLC Ladder Logic for Motor Control

PLC Program for Motor Starter

Control Valves Chemical attack Problems

Control Valves Chemical attack Problems

Phase Controlled Half Wave Rectifier RL Load

Power Electronics – Phase Controlled Half Wave Rectifier RL Load

Programming with Schneider PLC

Mail Box Automation: Programming with Schneider PLC

Foundation Fieldbus Interview Questions and Answers

Foundation Fieldbus Interview Questions and Answers

Example of PID Control Instruction

How to Configure PID in Siemens PLC?

transistor-emitter-bias

Transistor Emitter Bias

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?