Common

Different Types of Threads based on 4 Standards

NPT, NPTF, BSPP, and BSPT

Knowing the thread designation is very important to choose the right connection in threaded joints.

The two major classifications are based on American ASME/ANSI and British BS standards.

Here we are going to look at four standards about different types of threads.

ASME B1.20.1 – NPT

ASME B1.20.1 is the standard that talks about pipe Threads for general purpose applications.

The most famous and common type of thread in this standard is NPT that is the abbreviation of National Pipe Taper.

National Pipe Taper (NPT)

Some manufacturers use other codes to indicated internal and external threads:

Note that MPT and FPT are not authorized by ANSI.

NPT(F) as the internal NPT is completely different from NPTF which is the subject of the ANSI B1.20.3.

Design of NPT

  • The angle between taper and center axis of the pipe is 1° 47’ 24” (1.7800°)
  • Truncation of roots and crests are flat
  • 60° thread angle

Commonly used sizes include 1/8, ¼, 3/8, ½, ¾, 1, 1 ¼, 1 ½, and 2 in.

NPT taper pipe threads are intended to be made up wrench-tight and with a sealant (ex. Teflon) whenever a pressure-tight joint is required.

ANSI B1.20.3 – NPTF

ANSI B1.20.3 is another American standard that deals with threads. The difference of the threads in this standard with NPT is that the threads are designed to seal pressure-tight joints without the necessity of using sealing compounds.

Construction

The roots of both the external and internal threads are truncated slightly more than the crests, roots have wider flats than crests so that metal-to-metal contact occurs at the crests and roots coincident with or prior to flank contact.

So, by this method, NPTF eliminates the spiral leakage path.

The table below shows the different types of thread presented in ANSI B1.20.3.

Note that NPTF has 2 classes, where a sealant is not used, there is more assurance of a pressure-tight seal for Class 2 threads than for Class 1 threads.

Obviously, to screw NPT to NPTF there is a need for the sealant to avoid leakage.

Beyond American standards, there are ISO ones also, which are totally different.

ISO 228-1 – BSPP

ISO 228-1 is presenting the threads types which do not provide pressure-tight joints. So, they need sealant.

As you see in the figure, the thread angle in ISO 228-1 is 55°. Therefore, it is impossible to screw NPT to BSPP.

Note that for external thread there is 2 tolerance class.

Class A is a finer one. In some documents, they are called Fine and Coarse.

“G” in this designation comes from Gas.

Designation

According to ISO 228-1, the threads are designed like examples in the below table:

ISO 7-1 Pressure tight – BSPT & BSPP

The last thread type that we are going to study in this article is the threads that are the subject of ISO 7-1.

ISO 7-1 presents internal and external threads where pressure-tight joints are made on the threads. The thread angle like ISO 228 is 55°.

The taper is 1:16, meaning that for every 16 units of measurement increase in the distance from the end, the diameter increases by 1 unit of measurement.

Designation

The external thread always is tapered but the internal thread has parallel type also.

The table below shows some designation examples.

Letter “R” comes from Rohr that means pipe in German. “P” is the first letter of Parallel and “C” from Conic.

Conclusion

The table below shows a summary of what we have studied:

Author: Hanif Yazdani

Read Next:

You've successfully subscribed !

View Comments

Share

Recent Articles

  • PLC Tutorials

Conveyor Sorting Machine PLC Program with Calculation Function

The conveyor sorting machine is widely used in the packing industries using the PLC program…

4 days ago
  • PLC Tutorials

Example of Flip-Flop PLC Program for Lamps Application

Learn the example of flip-flop PLC program for lamps application using the ladder logic to…

4 days ago
  • PLC Tutorials

STAR DELTA Programming using PLC Controller

In this article, you will learn the STAR DELTA programming using PLC controller to start…

5 days ago
  • Instrumentation Design

Single and Three Phase Immersion Electrical Heaters Wiring Circuits

Lube oil consoles of rotary equipment packages in industrial process plants are usually equipped with…

2 days ago
  • Instrumentation Design

Immersion Heaters in Lube Oil Consoles

Rotating equipment packages such as pumps, compressors, turbines need the lube oil consoles for their…

4 days ago
  • PLC Tutorials

How to Blink Lights in Ladder Logic?

This article explains how to blink lights in ladder logic with a detailed explanation video…

4 weeks ago