    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: Multistage Flash Drums Erratic Level Readings
Share
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Root Cause Analysis (RCA) > Multistage Flash Drums Erratic Level Readings

Multistage Flash Drums Erratic Level Readings

Instrumentation engineering root cause analysis of multistage flash drums erratic level instrument readings.

Last updated: September 28, 2022 2:55 pm
S Raghava Chari
Root Cause Analysis (RCA)
No Comments
Share
4 Min Read
SHARE

Instrumentation engineering root cause analysis of multistage flash drums erratic level instrument readings.

Contents
Multistage Flash Drums Erratic Level ReadingsAuthor RCARoot Cause IdentifiedRoot Cause RemovedRoot Cause found solution implementedRoot Cause Solution Benefits
Article Type:Root Cause Analysis (RCA)
Category:Instrumentation
Equipment Type:Sensors
Author:S. Raghava Chari

Note: This root cause analysis (RCA) is from real-time scenarios that happened in industries during the tenure of two or three decades ago. These articles will help you to improve your troubleshooting skills and knowledge.

Multistage Flash Drums Erratic Level Readings

High Pressure (HP) side extended seal diaphragm differential pressure transmitters (DPT) never developed pinholes, unlike the previously discussed urea plant seal DPTs, shop calibrated, and static pressure tests passed before field installation.

Yet the 5-stages flash drums erratic level readings stopped the 750 T/d NH3 commissioning.

Author RCA

Because of drift-free calibration, all differential pressure level transmitters (DPLT) erratic outputs and the excellent brand name the author’ attributed root cause was:

HP, LP or both representative signals did not reach the differential pressure level transmitters (DPLT).  Therefore, he studied the high-pressure (HP) and low-pressure (LP) taps carefully from the vessel drawing and noted the following

  1. The 4” flanged HP extended diaphragm immerses fully in tranquil liquid NH3 contained in each stage chamber. Hence, the DP senses representative HP signal
  2. Welded to the previous stage bottom a 300 mm long extension skirt forms a 150 mm radial width annulus (below figure)
  3. Liquid NH3 from the previous higher pressure stage enters the annulus tangentially – a process requirement
  4. The DPLT LP tap senses the annulus gas pressure
Multistage Flash Drums Erratic Level Readings

Root Cause Identified

He considered these observations and concluded:

  1. The tangential entry and liquid evaporation cause unsteady pulsating annulus pressures
  2. The DPLT LP port senses this pulsating unrepresentative pressures – the erratic liquid NH3 level readings Root Cause disturbances could be causing the DPLTs outputted erratic level signals..

Root Cause Removed

½ hour thought flashed solution was: insert a supplementary nozzle via the LP tap penetrating ½‑extension skirt (above figure) to feed the skirt tranquil pressure to the DPLT LP port.

The diagnosed root cause impressed management ordered, “Go ahead; modify all stages LP taps”, to avoid a second shutdown if this step succeeds.

Root Cause found solution implemented

A crew took the below-listed steps:

  1. They inserted a shop made 100 mm long guide bush in the LP tap and bolted a flange over it
  2. A long drill passing through the guide bush bore drilled 20 mm dia hole in the skirt wall
  3. The crew inserted the shop made supplementary nozzle secured it bolting a flange
  4. Instrument crew connected the supplementary nozzle to the DPLT LP port
  5. Mech and Inst crew did these for all stages

Root Cause Solution Benefits

The DPTs read correctly, as expected, and commissioning progressed rapidly.

Author: S. Raghava Chari

Do you face any similar issues? Share with us through the below comments section.

If you liked this article, then please subscribe to our YouTube Channel for Instrumentation, Electrical, PLC, and SCADA video tutorials.

You can also follow us on Facebook and Twitter to receive daily updates.

Read Next:

  • Turbine Flow Meter Constraints
  • Pitot-tube Replaced with Orifice
  • Mechanical Temperature Indicator
  • Pressure Transmitter Stopped Working
  • Seal Pressure Instruments Problems
Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Ammonia Feed Ball Valve to Ship Tank Closed
Thermowell Shank to Flange Repeat Weld Leaks
18 Temperature Sensors Fault Leads to Plant Shutdown
Seal Pressure Instruments Root Cause Analysis
Steam Letdown Station Problems and their Solutions
Mechanical Engineering Plant Problems Solved – Root Cause Analysis
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

HT Motor Problem appears after Disassembly and Reassembly
RCA – Compressor Did Not Trip on Suction Pressure Low Low
High-pressure Service Level Transmitters Misunderstood Zero Drifts
Leaky Boiler Drum Level Switch Stops NH3 Plant Commissioning
NH3 Plant Turbo-compressor Sudden Rise in Temperature
Centrifugal Compressor near ½-RPM Frequency High Magnitude Shaft Vibrations
Plant Air Storage Tank Pressure Fluctuations Root Cause Analysis
Cooling Tower Fans Frequently Failing

Keep Learning

Doubtful Temperature Readings

Doubtful Temperature Readings threatens Soaking Pit Wrecks 

Solenoid Valve Failure in Plant Start-Up

Solenoid Valve Failure in Plant Start-Up: Identifying the Root Cause

Leaking Plug Valves pose Safety Hazards and Lead to Plant Shutdown

Leaking Plug Valves Pose Safety Hazards and Lead to Plant Shutdown

Packaging Machinery

Poor Bagging Scale Availability Threatened Production Cuts

Turbine to Gearbox Alignment Drifts Caused Pump Transfers Problems

RCA Related to Trip Throttle Valve (TTV)

Recurring Short Circuit Flash Overs Safety Hazards

Recurring Short Circuit Flash Overs Safety Hazards & Damages

Process Air Compressor Overhauls Eliminated

Process Air Compressor too Frequent & too Lengthy Overhauls Eliminated

Plant Shutdown Analysis: Valve Closed and SOV Coil Failure

Plant Shutdown Analysis: Valve Closed and SOV Coil Failure

Learn More

Linear Programming in Excel

How to Do Linear Programming in Excel?

failure rate of a component - 1

Failure rate and MTBF of Safety Instrumented Systems

PLC analog output card

PLC Analog I/O and Network I/O

Power Electronics Objective Questions

AC Voltage Controllers Objective Questions

Selecting the Proper Failure Mode

How to Select Control Valve Failure Mode

Grounding Electronic Equipment

Importance of Grounding Electronic Equipment

Liquid Level Measurement using Pressure Transmitter

Liquid Level Measurement using Pressure Transmitter Questions

DC Circuit

Main differences between Sinking and Sourcing Circuits

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?