Inst ToolsInst ToolsInst Tools
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Search
  • Books
  • Software
  • Projects
  • Process
  • Tools
  • Basics
  • Formula
  • Power Plant
  • Root Cause Analysis
  • Electrical Basics
  • Animation
  • Standards
  • 4-20 mA Course
  • Siemens PLC Course
Reading: What is Gas-Insulated Transmission Line? Principle Advantages
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
  • Request
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Electrical Basics > What is Gas-Insulated Transmission Line? Principle Advantages

What is Gas-Insulated Transmission Line? Principle Advantages

A Gas-Insulated Transmission Line (GIL) is a power transmission system that uses gas like SF6 for insulation instead of air.

Last updated: December 1, 2024 10:49 am
Viral Nagda
Electrical Basics
No Comments
Share
6 Min Read
SHARE

There are two general types of electricity transmission lines – overhead and underground. Overhead wires can be seen by us daily in our lives, wherever we travel. Underground cables are laid wherever overhead connection is not possible.

Contents
What is a gas insulated line?Construction of gas-insulated lineAdvantages of Gas-Insulated Transmission LineDisadvantages of Gas-Insulated Transmission Line

But many of us do not know that there is even a third method for transmission – a gas-insulated transmission line. A gas-insulated line is a very important concept to understand, because it helps in critical areas where both the overhead and underground cabling is not possible. In this post, we will see what a gas-insulated transmission line is.

A Gas-Insulated Transmission Line (GIL) is a power transmission system that uses gas like SF6 for insulation instead of air.

What is a gas insulated line?

Gas-Insulated Transmission Line

In some big clustered areas like city skyscrapers or critical industrial sites where laying overhead or underground electric transmission cables is not possible, there arises a need to lay some other form of cable for power. This is done with the help of gas-insulated transmission lines. Also known as GIL, it is a conductor cable which is insulated from outside with a gas, mostly fully SF6 or a mixture of SF6 and N2.

The whole setup is then covered with a metal casing and laid as a pipeline. So, as it appears from outside as a pipeline, it is actually an electrical transmission line. The gases are used because they have a very high dielectric strength and thus have excellent insulating properties.

They can transmit current of up to 3000 MVA, thus proving as a very good alternative over traditional transmission lines.

Construction of gas-insulated line

Refer to the below image. A GIC consists of a metal tube enclosure (mostly aluminum), which is the outermost body and which will be exposed to the atmosphere. Inside this enclosure comes the gas which will be filled fully between the conductor (mostly 50 cm. thick and the metal body.

Now, to support the conductor wire, a normal support insulator (disc or support epoxy resin) stand is used to hold them. This structure is also called single encapsulation GIC (which supports only single-phase wire). There is also another structure called a three encapsulation GIC (which supports three phase wires in a single tube).

But, for higher voltages (above 145KV), single encapsulation is more preferred. So, for a three phase wire, you will require three such encapsulations. The gas filled in between can be either only SF6 or a composition of SF6 and N2. In the composition mixture, the proportion of N2 is more and SF6 is less.

As it has very high dielectric properties, it prevents the formation of electric fields and arcs around them and thus, holds the electric current from flowing in the conductor wire only. So, even if you touch these metal bodies from outside, you will not get an electric shock.

Construction of gas-insulated line

As GIL fully resembles a pipeline architecture, it can be mounted either above the ground level or dug underground. It can also be mounted vertically over a structure. This makes it fully flexible for installation and commissioning. Remember to properly earth the outer metal body for safety purposes.

Advantages of Gas-Insulated Transmission Line

  1. There is no risk of electric shock or fire as the metal body is highly reliable, and also the gas has very strong insulation properties.
  2. It is less susceptible to electromagnetic noise, pollution, dirt and transmission losses (usually observed in overhead and underground direct cables).
  3. Easy for installation and commissioning due to pipeline architecture.
  4. Less carbon footprint for the environment.
  5. The lifetime of this cable is more than underground or overhead cables.
  6. You can use them easily in highly polluted or critical areas, due to the strong resistance it provides to the outer environmental conditions.

Disadvantages of Gas-Insulated Transmission Line

  1. Due to the use of gas, the investment required in using GIL is very high as compared to normal transmission lines. So, they are not used frequently and used only in some specific or critical areas.
  2. SF6 gas is itself harmful for the environment, if exposed to the atmosphere at any point by mistake. It is a very dangerous gas for the greenhouse. That is why it is used along with nitrogen gas for a safe mixture and performance.
  3. Skilled manpower is required for installation and commissioning.
  4. The pressure at which the gas is filled must be maintained at each and every point; any reduction in pressure will result in failure of insulation.

In this way, we saw what is a gas-insulated transmission line.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

How Do Electrical Shorts and Ground Faults Trip Circuit Breakers?
Electrical Motor Terms and Concepts
How to Connect a 3 Phase Motor in Star and Delta Connections?
Why is Phase Failure Relay Required in LV Panels?
What is SMPS? – Types of SMPS
Geothermal Energy Power Plants
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Bus Riser in Switchgear
Working Principle of Overload Relay
How to Locate Faults in Cables? – Fault Analysis & Location
What is a Capacitor Bank?
Dahlander Motors – Principle, Advantages, Disadvantages
How does Electrical Power Outlet Work?
Electrical Drawings
Difference between Current Transformer and Potential Transformer

Keep Learning

Garage Door Roller Shutter

Shutter Door Control using Motor and Limit Switches

Electrical Conduit

What is Electrical Conduit? Types, Advantages, Disadvantages

VFD Engineer Roles - Installation and Commissioning

VFD Engineer Roles – Installation and Commissioning

Partial Discharge in Power Lines and its Detection through Sensors

Partial Discharge in Power Lines and its Detection through Sensors

Why Are Neutral and Earth Separated

Why Are Neutral and Earth Separated?

Clamp Meter

Things to Know When Measuring Current

Electric Motors Noises

Electric Motors Noises – Types, Possible Sources, Reasons

Pros and Cons of Soft Starter

Pros and Cons of Soft Starter

Learn More

How to test SCR using Multimeter

How to test SCR using Multimeter

Garage Door Roller Shutter

Shutter Door Control using Motor and Limit Switches

PLC Technique for IO Mapping

PLC Techniques for I/O Mapping

How a Diode Works Animation

How a Gate Works ?

Reactor Top lid lapped

Urea Reactor Top Bolted Plug developed Leaks

PLC Programming for Garden Sprinkle System

PLC Programming for Garden Sprinkler System

Loop Current Step Response (LCSR) Test for RTD

Response Time Test of RTD and Thermocouple

Question on Analytical Controller

Question on Analytical Controller

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?