Reading: How do LED Stumps in Cricket Work?
Share
Notification Show More
Font ResizerAa
Inst ToolsInst Tools
Font ResizerAa
  • Courses
  • Design
  • PLC
  • Interview
  • Control System
Search
  • Courses
  • Automation
    • PLC
    • Control System
    • Safety System
    • Communication
    • Fire & Gas System
  • Instrumentation
    • Design
    • Pressure
    • Temperature
    • Flow
    • Level
    • Vibration
    • Analyzer
    • Control Valve
    • Switch
    • Calibration
    • Erection & Commissioning
  • Interview
    • Instrumentation
    • Electrical
    • Electronics
    • Practical
  • Q&A
    • Instrumentation
    • Control System
    • Electrical
    • Electronics
    • Analog Electronics
    • Digital Electronics
    • Power Electronics
    • Microprocessor
Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Inst Tools > Blog > Control Systems > How do LED Stumps in Cricket Work?

How do LED Stumps in Cricket Work?

LED stumps in cricket are equipped with sensors and illuminate when dislodged, instantly signaling a wicket event.

Last updated: January 23, 2024 1:48 pm
Viral Nagda
Control Systems
No Comments
Share
4 Min Read
SHARE

Electronic technology is evolving day by day and we are getting to see many new technologies in it. As electronics is widely used in many areas of applications, every application is finding some new methods to make it innovative.

Contents
Why LED Wicket System is used?LED Stumps in Cricket

Let us take sports application. Recently, you must have seen cricket and in that, how LED light comes from bails that are mounted on stumps. When the bails are dislodged from the stumps on a wicket, LED light comes from it.

LED stumps help to easily recognize whether a wicket has fallen or not. But have you ever wondered how this light occurs? In this post, we will see how an LED wicket in a cricket stump works.

Why LED Wicket System is used?

LED Stumps in Cricket

As discussed earlier, an umpire gets to easily identify whether a wicket has fallen or not. Three types of wickets relate to a stump – clean bowled, run-out, or stumping. It happens many times that the ball hits the stump, but the bail does not fall.

And unless the bail has not dislodged from the stump, it is not declared out. This case is more difficult in run-out or stumping because the umpire has to decide whether the bat has reached the crease or not before the bail has dislodged.

In this case, a system was recently introduced where the bail will emit light as soon as it has dislodged from the stumps. This visual recognition helps the umpire to declare a wicket easily.

Also, as this method is precise, there are rare chances of a mistaken review given by the umpire.

LED Stumps in Cricket

Now, let us see how this system works. Refer to the below image. As you can see, two bails are mounted on stumps. Each bail has a low-voltage battery inside it.

How do LED Stumps in Cricket Work

Apart from it, it also consists of a magnetic circuit and an LED circuit. The battery will power the bail. It is to be noted that the stump too has a magnetic circuit and battery. The only difference being extra is that the bail has an LED circuit.

The magnets decide whether the bail is dislodged or not. When the bail is properly mounted, the magnets will attract each other and the switch inside will remain open. This will not trigger the LED. But, when the bail gets dislodged, the magnets will repel each other. Due to this, the switch inside will get closed on detecting it.

As soon as the switch closes, the LED trigger circuit gets charged for powering up. This will lighten up the LED. The triggering speed is so fast that it works at a time of 1/1000th second. This is lighting fast and quickly helps the umpire to detect a wicket.

The trigger circuit used for powering on or off an LED is usually a Schmitt trigger circuit. It continuously monitors the magnetic field and any change in electromagnetic field will ask the trigger circuit to close the switch and power on the LED. This change is so accurate that it can detect even the slightest movement of the bail from stumps.

The material used for bails and stumps outside is a plastic composite one. This can tolerate fast bowling up to 160 km/hr. Due to this, the bail or stump will not break; otherwise, the electronic circuit inside will break too. So, the material used is of utmost importance.

Don't Miss Our Updates
Be the first to get exclusive content straight to your email.
We promise not to spam you. You can unsubscribe at any time.
Invalid email address
You've successfully subscribed !

Continue Reading

Speed Control of Ship Electrical Motor Propulsion
How-to Create Instrument Loop Diagram (ILD)?
Emergency Stop Switch Spurious Trip
Hardware Troubleshooting Steps for PLC Automation Systems
Process Control High Level Alarm Fault Analysis
Anti-static Wrist Straps in Industrial Automation
Share This Article
Facebook Whatsapp Whatsapp LinkedIn Copy Link
Share
Leave a Comment

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Stay Connected

128.3kFollowersLike
69.1kFollowersFollow
210kSubscribersSubscribe
38kFollowersFollow

Categories

Explore More

Fiber Optic Cable – Method of Joining and Fusion Splicing
Standard Colors in PLC Automation Systems
Vendor View of Supplying Industrial Process Control & Safety Systems
Tips for Reducing the Noise Signals
Supervisory Control
Why Offset in Proportional Controller ?
What is Alarm Management System ?
Why Bias used in Proportional Controller ?

Keep Learning

Example of feedback principle

Example of Feedback System

What is Instrumentation and Control

What is Instrumentation and Control ?

Boiler Three Element Controller Philosophy

Boiler Three Element Controller Philosophy

HMI

Learn about SCADA and HMI Systems

Questions on Single Loop Controller

Single Loop Controller Questions

Inspection and Testing of Fiber Optic Cable

Inspection and Testing of Fiber Optic Cable

how-to-avoid-bad-grounds

How to Avoid Bad Grounds ?

Control system architecture diagrams

Vendor Document for Project Systems Architecture

Learn More

Troubleshooting Pump Control Circuit

Troubleshooting Pump Control Circuit

PLC Sequential Lights Control Example

PLC Timer Example: Sequential Control of Three Lights with Reset

P&ID

Over Pressure Protection Devices

Electrical Wiring Terminology

Electrical Wiring Terminology

Guided wave radar Measurement Principle

Guided Wave Radar – Principle, Limitations, Installation

PLC Programming Examples using Timer

Basic PLC Ladder Programming Example

Function Module in Siemens PLC

What is Function Module in Siemens PLC?

Instrumentation Engineering Quiz

Instrumentation Engineering Quiz – Set 2

Menu

  • About
  • Privacy Policy
  • Copyright

Quick Links

  • Learn PLC
  • Helping Hand
  • Part Time Job

YouTube Subscribe

Follow US
All rights reserved. Reproduction in whole or in part without written permission is prohibited.
Welcome Back!

Sign in to your account

Username or Email Address
Password

Lost your password?